Comparison of propagation- and grating-based x-ray phase-contrast imaging techniques with a liquid-metal-jet source

X-ray phase-contrast imaging has been developed as an alternative to conventional absorption imaging, partly for its dose advantage over absorption imaging at high resolution. Grating-based imaging (GBI) and propagation-based imaging (PBI) are two phase-contrast techniques used with polychromatic laboratory sources. We compare the two methods by experiments and simulations with respect to required dose. A simulation method based on the projection approximation is designed and verified with experiments. A comparison based on simulations of the doses required for detection of an object with respect to its diameter is presented, showing that for monochromatic radiation, there is a dose advantage for PBI for small features but an advantage for GBI at larger features. However, GBI suffers more from the introduction of polychromatic radiation, in this case so much that PBI gives lower dose for all investigated feature sizes. Furthermore, we present and compare experimental images of biomedical samples. While those support the dose advantage of PBI, they also highlight the GBI advantage of quantitative reconstruction of multimaterial samples. For all experiments a liquid-metal-jet source was used. Liquid-metal-jet sources are a promising option for laboratory-based phase-contrast imaging due to the relatively high brightness and small spot size.

[1]  A Bravin,et al.  Analytical and experimental determination of signal-to-noise ratio and figure of merit in three phase-contrast imaging techniques. , 2012, Optics express.

[2]  V. Cnudde,et al.  Software tools for quantification of X-ray microtomography at the UGCT , 2007 .

[3]  Rainer Raupach,et al.  Analytical evaluation of the signal and noise propagation in x-ray differential phase-contrast computed tomography , 2011, Physics in medicine and biology.

[4]  Lynn Kissel,et al.  RTAB: the Rayleigh scattering database , 2000 .

[5]  A. Rose The sensitivity performance of the human eye on an absolute scale. , 1948, Journal of the Optical Society of America.

[6]  Marco Stampanoni,et al.  X-ray grating interferometry with a liquid-metal-jet source , 2013 .

[7]  S. Wilkins,et al.  Phase-contrast imaging using polychromatic hard X-rays , 1996, Nature.

[8]  Rainer Raupach,et al.  Performance evaluation of x-ray differential phase contrast computed tomography (PCT) with respect to medical imaging. , 2012, Medical physics.

[9]  R. Kaufmann,et al.  Noise analysis of grating-based x-ray differential phase contrast imaging. , 2010, The Review of scientific instruments.

[10]  Harrison H. Barrett,et al.  Foundations of Image Science , 2003, J. Electronic Imaging.

[11]  O. Bunk,et al.  Hard-X-ray dark-field imaging using a grating interferometer. , 2008, Nature materials.

[12]  Thomas Köhler,et al.  Noise properties of grating-based x-ray phase contrast computed tomography. , 2011, Medical physics.

[13]  O. Bunk,et al.  Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources , 2006 .

[14]  J. Baró,et al.  PENELOPE: An algorithm for Monte Carlo simulation of the penetration and energy loss of electrons and positrons in matter , 1995 .

[15]  O. Bunk,et al.  Hard x-ray phase tomography with low-brilliance sources. , 2007, Physical review letters.

[16]  Franz Pfeiffer,et al.  X-ray phase imaging with a grating interferometer. , 2005, Optics express.

[17]  J. H. Hubbell,et al.  Tables of X-Ray Mass Attenuation Coefficients and Mass Energy-Absorption Coefficients 1 keV to 20 MeV for Elements Z = 1 to 92 and 48 Additional Substances of Dosimetric Interest , 1995 .

[18]  S. Wilkins,et al.  Simultaneous phase and amplitude extraction from a single defocused image of a homogeneous object , 2002, Journal of microscopy.

[19]  H M Hertz,et al.  Comparison of Two X-ray Phase-contrast Imaging Methods with a Microfocus Source References and Links , 2022 .

[20]  Guang-Hong Chen,et al.  Fundamental relationship between the noise properties of grating-based differential phase contrast CT and absorption CT: theoretical framework using a cascaded system model and experimental validation. , 2013, Medical physics.

[21]  Franz Pfeiffer,et al.  Numerical comparison of X-ray differential phase contrast and attenuation contrast , 2012, Biomedical optics express.

[22]  Ke Li,et al.  Scaling law for noise variance and spatial resolution in differential phase contrast computed tomography. , 2010, Medical physics.

[23]  H M Hertz,et al.  X-ray phase contrast for CO2 microangiography , 2012, Physics in medicine and biology.

[24]  P. C. Diemoz,et al.  Theoretical comparison of three X-ray phase-contrast imaging techniques: propagation-based imaging, analyzer-based imaging and grating interferometry. , 2012, Optics express.

[25]  Xiangyang Tang,et al.  Characterization of imaging performance in differential phase contrast CT compared with the conventional CT--noise power spectrum NPS(k). , 2011, Medical physics.