Modeling and Optimization of a CoolingTower-Assisted Heat Pump System

To minimize the total energy consumption of a cooling tower-assisted heat pump (CTAHP) system in cooling mode, a model-based control strategy with hybrid optimization algorithm for the system is presented in this paper. An existing experimental device, which mainly contains a closed wet cooling tower with counter flow construction, a condenser water loop and a water-to-water heat pump unit, is selected as the study object. Theoretical and empirical models of the related components and their interactions are developed. The four variables, viz. desired cooling load, ambient wet-bulb temperature, temperature and flow rate of chilled water at the inlet of evaporator, are set to independent variables. The system power consumption can be minimized by optimizing input powers of cooling tower fan, spray water pump, condenser water pump and compressor. The optimal input power of spray water pump is determined experimentally. Implemented on MATLAB, a hybrid optimization algorithm, which combines the Limited memory Broyden-Fletcher-Goldfarb-Shanno (L-BFGS) algorithm with the greedy diffusion search (GDS) algorithm, is incorporated to solve the minimization problem of energy consumption and predict the system’s optimal set-points under quasi-steady-state conditions. The integrated simulation tool is validated against experimental data. The results obtained demonstrate the proposed operation strategy is reliable, and can save energy by 20.8% as compared to an uncontrolled system under certain testing conditions.

[1]  Dominique Marchio,et al.  Simplified model for indirect-contact evaporative cooling-tower behaviour , 2004 .

[2]  Andrew Kusiak,et al.  Modeling and optimization of a chiller plant , 2014 .

[3]  Jorge Nocedal,et al.  On the limited memory BFGS method for large scale optimization , 1989, Math. Program..

[4]  Jinqing Peng,et al.  Performance Analyses of Counter-Flow Closed Wet Cooling Towers Based on a Simplified Calculation Method , 2017 .

[5]  James E. Braun,et al.  Empirical modeling of the impacts of faults on water-cooled chiller power consumption for use in building simulation programs , 2016 .

[6]  Shengwei Wang,et al.  Development and validation of an effective and robust chiller sequence control strategy using data-driven models , 2016 .

[7]  Ashwin M. Khambadkone,et al.  Energy optimization methodology of multi-chiller plant in commercial buildings , 2017 .

[8]  Nianping Li,et al.  Study of Heat-source-Tower Heat Pump System Efficiency☆ , 2015 .

[9]  S. Yoo,et al.  Thermal performance analysis of heat exchanger for closed wet cooling tower using heat and mass transfer analogy , 2010 .

[10]  Kok Lay Teo,et al.  A hybrid approach to constrained global optimization , 2016, Appl. Soft Comput..

[11]  Hoseyn Sayyaadi,et al.  Multi-objective optimization of a cooling tower assisted vapor compression refrigeration system , 2011 .

[12]  Nianping Li,et al.  Analysis of the Effect of the CaCl 2 Mass Fraction on the Efficiency of a Heat Pump Integrated Heat-Source Tower Using an Artificial Neural Network Model , 2016 .

[13]  R. Chargui,et al.  Numerical simulation of a cooling tower coupled with heat pump system associated with single house using TRNSYS , 2013 .

[14]  Lihua Xie,et al.  HVAC system optimization––condenser water loop , 2004 .

[15]  Shui Yuan,et al.  Optimizing energy consumption of a water-loop variable-speed heat pump system , 2011 .

[16]  Mostafa Nejatolahi,et al.  Thermodynamic and thermoeconomic optimization of a cooling tower-assisted ground source heat pump , 2011 .

[17]  Zhenjun Ma,et al.  Supervisory and optimal control of central chiller plants using simplified adaptive models and genetic algorithm , 2011 .

[18]  Zhiguo Wang,et al.  A limited memory BFGS-type method for large-scale unconstrained optimization , 2008, Comput. Math. Appl..

[19]  Farrokh Janabi-Sharifi,et al.  Review of modeling methods for HVAC systems , 2014 .

[20]  Y. Chuah,et al.  A study on an optimal approach temperature control strategy of condensing water temperature for energy saving , 2011 .

[21]  Kok Lay Teo,et al.  A new exact penalty method for semi-infinite programming problems , 2014, J. Comput. Appl. Math..

[22]  Yaoyu Li,et al.  A Multivariable Newton-Based Extremum Seeking Control for Condenser Water Loop Optimization of Chilled-Water Plant , 2015 .