Effect of ventilation systems and air filters on decay rates of particles produced by indoor sources in an occupied townhouse

Abstract Several studies have shown the importance of particle losses in real homes due to deposition and filtration; however, none have quantitatively shown the impact of using a central forced air fan and in-duct filter on particle loss rates. In an attempt to provide such data, we measured the deposition of particles ranging from 0.3 to 10 μm in an occupied townhouse and also in an unoccupied test house. Experiments were run with three different sources (cooking with a gas stove, citronella candle, pouring kitty litter), with the central heating and air conditioning (HAC) fan on or off, and with two different types of in-duct filters (electrostatic precipitator and ordinary furnace filter). Particle size, HAC fan operation, and the electrostatic precipitator had significant effects on particle loss rates. The standard furnace filter had no effect. Surprisingly, the type of source (combustion vs. mechanical generation) and the type of furnishings (fully furnished including carpet vs. largely unfurnished including mostly bare floor) also had no measurable effect on the deposition rates of particles of comparable size. With the HAC fan off, average deposition rates varied from 0.3 h−1 for the smallest particle range (0.3–0.5 μm) to 5.2 h−1 for particles greater than 10 μm. Operation of the central HAC fan approximately doubled these rates for particles

[1]  D Fugler,et al.  REDUCING PARTICULATE LEVELS IN HOUSES , 2002 .

[2]  Alvin C.K. Lai,et al.  Modeling Indoor Particle Deposition from Turbulent Flow onto Smooth Surfaces , 2000 .

[3]  Lance Wallace,et al.  Continuous Monitoring of Ultrafine, Fine, and Coarse Particles in a Residence for 18 Months in 1999-2000 , 2002, Journal of the Air & Waste Management Association.

[4]  Guk-Rwang Won American Society for Testing and Materials , 1987 .

[5]  P J Catalano,et al.  Using time- and size-resolved particulate data to quantify indoor penetration and deposition behavior. , 2001, Environmental science & technology.

[6]  David T. Grimsrud,et al.  Control of respirable particles in indoor air with portable air cleaners , 1985 .

[7]  R. Sextro,et al.  Deposition of Tobacco Smoke Particles in a Low Ventilation Room , 1994 .

[8]  Thomas E McKone,et al.  Indoor particulate matter of outdoor origin: importance of size-dependent removal mechanisms. , 2002, Environmental science & technology.

[9]  A. Lai Particle deposition indoors: a review. , 2002, Indoor air.

[10]  R. Jayanty,et al.  Measurement of toxic and related air pollutants , 1990 .

[11]  L. Wallace,et al.  Continuous measurements of air change rates in an occupied house for 1 year: The effect of temperature, wind, fans, and windows* , 2002, Journal of Exposure Analysis and Environmental Epidemiology.

[12]  J. Xue,et al.  Personal exposure to airborne particles and metals: results from the Particle TEAM study in Riverside, California. , 1996, Journal of exposure analysis and environmental epidemiology.

[13]  L. E. Sparks,et al.  Penetration of Ambient Fine Particles into the Indoor Environment , 2001 .

[14]  William W. Nazaroff,et al.  Mathematical Modeling of Indoor Aerosol Dynamics , 1989 .

[15]  Antony J. H. Goddard,et al.  Size specific indoor aerosol deposition measurements and derived I/O concentrations ratios , 1997 .

[16]  Paul J. Catalano,et al.  Relative contribution of outdoor and indoor particle sources to indoor concentrations , 2000 .

[17]  Tracy L. Thatcher,et al.  Deposition, resuspension, and penetration of particles within a residence , 1995 .

[18]  P. Lawless,et al.  Characterization of Indoor-Outdoor Aerosol Concentration Relationships during the Fresno PM Exposure Studies , 2001 .

[19]  Tracy L. Thatcher,et al.  Effects of room furnishings and air speed on particle deposition rates indoors , 2002 .

[20]  L. Wallace,et al.  Indoor particles: a review. , 1996, Journal of the Air & Waste Management Association.

[21]  Steven J. Emmerich,et al.  Measurement and Simulation of the IAQ Impact of Particle Air Cleaners in a Single-Zone Building , 2000 .