Flow-rate Characteristics Measurement of Regulators Based on the Pressure Response in an Isothermal Tank

Regulators are important components in pneumatic system,and their flow-rate characteristics are the key parameters for designers.According to the correlatively international standard and national standard of China,which describe the flow-rate characteristics measurement method of pneumatic regulators,the pressure and the flow are measured point by point,and then the flow-rate characteristics curve is plotted point to point.This method has some disadvantages,such as equipment complexity,much air consumption,and low efficiency.To settle the problems presented above,this paper puts forward a new high efficient and energy saving flow-rate characteristics measurement method of regulators,which is based on the pressure response when charging and discharging to an isothermal tank without any flow meters.The measurement principle,the system and the steps are introduced.And the tracking differentiator is used for the data processing of the pressure difference.Two typical kinds of regulators were experimentally investigated,and their flow-rate characteristics curves were obtained with the new and the conventional method,respectively.Comparatively,it's proved that this new method is feasible because it is not only able to meet the demand of the measurement precision,but also to save energy and improve efficiency.Compared to the conventional method,the new method takes only about 1/10 amount of time and consumes about only 1/30 amount of air.Hopefully it will be able to serve as an international standard of flow-rate characteristics measurement method of regulators.