Radon equilibrium factor and perceived air quality in an air-conditioned auditorium in Lublin, Poland

The study reports measurements of radon and its decay products and of perceived air quality carried out in an occupied and unoccupied auditorium at the Lublin University of Technology in Lublin, Poland during three air conditioning system operation modes – air conditioning off, air conditioning on and air conditioning on/off. In the air conditioning on/off mode radon and its decay product concentrations and values of perceived air quality were inversely related. During that air conditioning operation mode, the value of the mean equilibrium factor F for the unattached fraction (0.31 ± 0.19) was somewhat higher than for the attached fraction (0.24 ± 0.19) and significant negative correlations were found between F values for attached, unattached and for the sum of both progeny fractions and perceived air quality values. These findings may be of importance as they indicate that in certain air conditioning operation modes indoor air quality deteriorates along with a reduction in the radon health hazard. This, in turn may adversely affect the comfort and productivity of the room users.

[1]  Z. Žunić,et al.  Variance of indoor radon concentration: Major influencing factors. , 2016, The Science of the total environment.

[2]  Kimberlee J. Kearfott,et al.  Influence of environmental factors on indoor radon concentration levels in the basement and ground floor of a building - A case study , 2015 .

[3]  P. Bala,et al.  Long-term simultaneous measurement of indoor concentration of radon and thoron progeny in the dwellings of Una and Hamirpur District of Himachal Pradesh , 2015 .

[4]  R. Mehra,et al.  Estimation of EEC, unattached fraction and equilibrium factor for the assessment of radiological dose using pin-hole cup dosimeters and deposition based progeny sensors. , 2015, Journal of environmental radioactivity.

[5]  Prabhjot Singh,et al.  A study of indoor radon, thoron and their progeny measurement in Tosham region Haryana, India , 2015 .

[6]  H. Yamazawa,et al.  Seasonal behavior of radon decay products in indoor air and resulting radiation dose to human respiratory tract , 2015 .

[7]  M. Dudzinska,et al.  Air conditioning impact on the dynamics of radon and its daughters concentration. , 2014, Radiation protection dosimetry.

[8]  J. Vinha,et al.  Review of low-energy construction, air tightness, ventilation strategies and indoor radon: results from Finnish houses and apartments. , 2014, Radiation protection dosimetry.

[9]  H. Yamazawa,et al.  The weather dependence of particle size distribution of indoor radioactive aerosol associated with radon decay products. , 2011, Radiation protection dosimetry.

[10]  N. Chankow,et al.  Mitigation of the effective dose of radon decay products through the use of an air cleaner in a dwelling in Okinawa, Japan. , 2009, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[11]  S. Tokonami,et al.  Characteristics of radon and its progeny concentrations in air-conditioned office buildings in Tokyo. , 2003, Radiation protection dosimetry.

[12]  F. Marley Utilisation of an Air-conditioning System to Control the Levels of Radon and Radon Progeny in a Workplace Environment , 2000 .

[13]  N. Todorović,et al.  RADON EQUILIBRIUM MEASUREMENT IN THE , 2013 .

[14]  M. Dudzinska,et al.  Ventilation control based on the CO2 and aerosol concentration and the perceived air quality measurements - a case study , 2010 .

[15]  B. Połednik,et al.  Study of the relationship between the perceived air quality and the specific enthalpy of air polluted by people , 2006 .

[16]  P. Phillips,et al.  Investigation of the potential for radon mitigation by operation of mechanical systems affecting indoor air. , 2001, Journal of environmental radioactivity.