Mitigate B1+ inhomogeneity by nonlinear gradients and RF shimming
暂无分享,去创建一个
I-Liang Chern | Teng-Yi Huang | Riccardo Lattanzi | Fa-Hsuan Lin | Yi-Cheng Hsu | Ying-Hua Chu | I. Chern | F. Lin | Ying-Hua Chu | R. Lattanzi | Teng-Yi Huang | Yi-Cheng Hsu
[1] Michael B. Smith,et al. Exploring the limits of RF shimming for high‐field MRI of the human head , 2006, Magnetic resonance in medicine.
[2] Douglas C Noll,et al. Fast‐kz three‐dimensional tailored radiofrequency pulse for reduced B1 inhomogeneity , 2006, Magnetic resonance in medicine.
[3] P. Börnert,et al. Transmit SENSE , 2003, Magnetic resonance in medicine.
[4] R. Goebel,et al. 7T vs. 4T: RF power, homogeneity, and signal‐to‐noise comparison in head images , 2001, Magnetic resonance in medicine.
[5] T. Ibrahim,et al. Effect of RF coil excitation on field inhomogeneity at ultra high fields: a field optimized TEM resonator. , 2001, Magnetic resonance imaging.
[6] Johnpauly. A k-Space Analysis of Small-Tip-Angle Excitation , 2012 .
[7] Peter Andersen,et al. 9.4T human MRI: Preliminary results , 2006, Magnetic resonance in medicine.
[8] Michael B. Smith,et al. Combination of optimized transmit arrays and some receive array reconstruction methods can yield homogeneous images at very high frequencies , 2005, Magnetic resonance in medicine.
[9] J W Carlson,et al. Electromagnetic fields of surface coil in vivo NMR at high frequencies , 1991, Magnetic resonance in medicine.
[10] Douglas C Noll,et al. Spatial domain method for the design of RF pulses in multicoil parallel excitation , 2006, Magnetic resonance in medicine.
[11] Michael B. Smith,et al. Central brightening due to constructive interference with, without, and despite dielectric resonance , 2005, Journal of magnetic resonance imaging : JMRI.
[12] Mark E Ladd,et al. RF excitation using time interleaved acquisition of modes (TIAMO) to address B1 inhomogeneity in high‐field MRI , 2010, Magnetic resonance in medicine.
[13] D. Sodickson,et al. Electrodynamic constraints on homogeneity and radiofrequency power deposition in multiple coil excitations , 2009, Magnetic resonance in medicine.
[14] G. Metzger,et al. Local B1+ shimming for prostate imaging with transceiver arrays at 7T based on subject‐dependent transmit phase measurements , 2008, Magnetic resonance in medicine.
[15] E. Atalar,et al. Specific absorption rate reduction using nonlinear gradient fields , 2013, Magnetic resonance in medicine.
[16] Steen Moeller,et al. A geometrically adjustable 16‐channel transmit/receive transmission line array for improved RF efficiency and parallel imaging performance at 7 Tesla , 2008, Magnetic resonance in medicine.
[17] Oliver Speck,et al. Parallel imaging in non-bijective, curvilinear magnetic field gradients: a concept study , 2008, Magnetic Resonance Materials in Physics, Biology and Medicine.
[18] Dan Xu,et al. Reduced field‐of‐view excitation using second‐order gradients and spatial‐spectral radiofrequency pulses , 2013, Magnetic resonance in medicine.
[19] P A Bottomley,et al. RF magnetic field penetration, phase shift and power dissipation in biological tissue: implications for NMR imaging. , 1978, Physics in medicine and biology.
[20] Gigi Galiana,et al. O‐space imaging: Highly efficient parallel imaging using second‐order nonlinear fields as encoding gradients with no phase encoding , 2010, Magnetic resonance in medicine.
[21] Steen Moeller,et al. B1 destructive interferences and spatial phase patterns at 7 T with a head transceiver array coil , 2005, Magnetic resonance in medicine.
[22] D. Alsop,et al. A spiral volume coil for improved RF field homogeneity at high static magnetic field strength , 1998, Magnetic resonance in medicine.
[23] K. Uğurbil,et al. Efficient high‐frequency body coil for high‐field MRI , 2004, Magnetic resonance in medicine.
[24] J. Duyn,et al. Tailored excitation using nonlinear B0‐shims , 2012, Magnetic resonance in medicine.