Evaluation of active anti-islanding methods based on the ABNT NBR IEC 62116 and IEEE STD 929-2000 standards

In this paper two active anti-islanding methods are evaluated and compared according to the ABNT NBR 62116 and IEEE STD 929-2000 standards. These standards specify voltage and frequency trip time settings and trip magnitudes. The first method is the active frequency drift with positive feedback and the second one is the active frequency jump that is based on phase-locked loop perturbation. The latter distorted less the power injected into the utility grid and had a better time response to detect grid faults. Besides, it was able to obey the two standards, different from the first one that was able to follow just the second standard.

[1]  Massimo Vitelli,et al.  A Technique for Improving P&O MPPT Performances of Double-Stage Grid-Connected Photovoltaic Systems , 2009, IEEE Transactions on Industrial Electronics.

[2]  V. Bufano,et al.  Innovative solutions to control unintentional islanding on LV network with high penetration of distributed generation , 2013 .

[3]  Marcelo Gradella Villalva,et al.  Input-controlled buck converter for photovoltaic applications: Modeling and design , 2008 .

[4]  Shridhar Sholapur,et al.  Boost Converter Topology for PV System with Perturb And Observe MPPT Algorithm , 2014 .

[5]  Marcel Istrate,et al.  A study on anti-islanding detection algorithms for grid-tied photovoltaic systems , 2014, 2014 International Conference on Optimization of Electrical and Electronic Equipment (OPTIM).

[6]  Chee Wei Tan,et al.  An Overview of Islanding Detection Methods in Photovoltaic Systems , 2011 .

[7]  Hannu Laaksonen New multi-criteria-based algorithm for islanding detection in smart grids , 2012, 2012 3rd IEEE PES Innovative Smart Grid Technologies Europe (ISGT Europe).

[8]  P. Garcia,et al.  Active Islanding Detection Using High-Frequency Signal Injection , 2012, IEEE Transactions on Industry Applications.

[9]  Leonardo Bruno Garcia Campanhol,et al.  Single-phase grid-tied photovoltaic system with boost converter and active filtering , 2014, 2014 IEEE 23rd International Symposium on Industrial Electronics (ISIE).

[10]  L.A.C. Lopes,et al.  Performance assessment of active frequency drifting islanding detection methods , 2006, IEEE Transactions on Energy Conversion.

[11]  Tamer Khatib,et al.  A review of islanding detection techniques for renewable distributed generation systems , 2013 .

[12]  Saurav Satpathy Photovoltaic power control using MPPT and boost converter , 2012 .

[13]  Yubin Wang,et al.  Comparison study of MPPT control strategies for double-stage PV grid-connected inverter , 2013, IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society.

[14]  Marco Liserre,et al.  Grid Converters for Photovoltaic and Wind Power Systems , 2011 .

[15]  Josep M. Guerrero,et al.  Microgrids in active network management – part II: System operation, power quality and protection , 2014 .

[16]  J. Choi,et al.  A Novel Active Frequency Drift Method of Islanding Prevention for the grid-connected Photovoltaic Inverter , 2005, 2005 IEEE 36th Power Electronics Specialists Conference.

[17]  P. Garcia,et al.  Active Islanding Detection for Multiple Parallel-Connected Inverter-Based Distributed Generators Using High-Frequency Signal Injection , 2014, IEEE Transactions on Power Electronics.

[18]  Ali M. Eltamaly,et al.  A comprehensive comparison of different MPPT techniques for photovoltaic systems , 2015 .

[19]  Hannu Laaksonen,et al.  Advanced Islanding Detection Functionality for Future Electricity Distribution Networks , 2013, IEEE Transactions on Power Delivery.