Consensus Guidelines for Implementing Pencil-Beam Scanning Proton Therapy for Thoracic Malignancies on Behalf of the PTCOG Thoracic and Lymphoma Subcommittee.

Pencil-beam scanning (PBS) proton therapy (PT), particularly intensity modulated PT, represents the latest advanced PT technology for treating cancers, including thoracic malignancies. On the basis of virtual clinical studies, PBS-PT appears to have great potential in its ability to tightly tailor the dose to the target while sparing critical structures, thereby reducing treatment-related toxicities, particularly for tumors in areas with complicated anatomy. However, implementing PBS-PT for moving targets has several additional technical challenges compared with intensity modulated photon radiation therapy or passive scattering PT. Four-dimensional computed tomography-based motion management and robust optimization and evaluation are crucial for minimizing uncertainties associated with beam range and organ motion. Rigorous quality assurance is required to validate dose delivery both before and during the course of treatment. Active motion management (eg, breath hold), beam gating, rescanning, tracking, or adaptive planning may be needed for cases involving significant motion or changes in motion or anatomy over the course of treatment.

[1]  Peter Balter,et al.  A comparison of tumor motion characteristics between early stage and locally advanced stage lung cancers. , 2012, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[2]  Jan-Jakob Sonke,et al.  Effects of anatomical changes on pencil beam scanning proton plans in locally advanced NSCLC patients. , 2016, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[3]  Steve B. Jiang,et al.  Effects of intra-fraction motion on IMRT dose delivery: statistical analysis and simulation. , 2002, Physics in medicine and biology.

[4]  S. L. Meeks,et al.  Direct Response to Proton Beam Linear Energy Transfer (LET) in a Novel Polymer Gel Dosimeter Formulation , 2012, Technology in cancer research & treatment.

[5]  A. Lomax,et al.  Intensity modulation methods for proton radiotherapy. , 1999, Physics in medicine and biology.

[6]  Antje Knopf,et al.  Mapping motion from 4D-MRI to 3D-CT for use in 4D dose calculations: A technical feasibility study. , 2013, Medical physics.

[7]  Timothy D. Solberg,et al.  Use of a novel two‐dimensional ionization chamber array for pencil beam scanning proton therapy beam quality assurance , 2015, Journal of applied clinical medical physics.

[8]  Zdenka Kuncic,et al.  Water and tissue equivalence of a new PRESAGE(®) formulation for 3D proton beam dosimetry: a Monte Carlo study. , 2012, Medical physics.

[9]  Jan-Jakob Sonke,et al.  Challenges of radiotherapy: report on the 4D treatment planning workshop 2013. , 2014, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[10]  International Commission on Radiation Units and Measurements , 2019 .

[11]  Xiaodong Zhang,et al.  Reducing Dose Uncertainty for Spot-Scanning Proton Beam Therapy of Moving Tumors by Optimizing the Spot Delivery Sequence. , 2015, International journal of radiation oncology, biology, physics.

[12]  Harald Paganetti,et al.  Motion mitigation for lung cancer patients treated with active scanning proton therapy. , 2015, Medical physics.

[13]  Marco Riboldi,et al.  Advances in 4D Treatment Planning for Scanned Particle Beam Therapy — Report of Dedicated Workshops , 2014, Technology in cancer research & treatment.

[14]  Keisuke Usui,et al.  Limited Impact of Setup and Range Uncertainties, Breathing Motion, and Interplay Effects in Robustly Optimized Intensity Modulated Proton Therapy for Stage III Non-small Cell Lung Cancer. , 2016, International journal of radiation oncology, biology, physics.

[15]  Shinichi Shimizu,et al.  Required transition from research to clinical application: Report on the 4D treatment planning workshops 2014 and 2015. , 2016, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[16]  T. Pan,et al.  4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT. , 2004, Medical physics.

[17]  Bijan Arjomandy,et al.  Patient-specific quality assurance for prostate cancer patients receiving spot scanning proton therapy using single-field uniform dose. , 2011, International journal of radiation oncology, biology, physics.

[18]  Jan-Jakob Sonke,et al.  Quantifying interfraction and intrafraction tumor motion in lung stereotactic body radiotherapy using respiration-correlated cone beam computed tomography. , 2009, International journal of radiation oncology, biology, physics.

[19]  Shinichi Shimizu,et al.  A Proton Beam Therapy System Dedicated to Spot-Scanning Increases Accuracy with Moving Tumors by Real-Time Imaging and Gating and Reduces Equipment Size , 2014, PloS one.

[20]  R. Mohan,et al.  A serial 4DCT study to quantify range variations in charged particle radiotherapy of thoracic cancers , 2013, Journal of radiation research.

[21]  C Bert,et al.  Motion in radiotherapy: particle therapy , 2011, Physics in medicine and biology.

[22]  Joe Y. Chang,et al.  Phase 2 study of high‐dose proton therapy with concurrent chemotherapy for unresectable stage III nonsmall cell lung cancer , 2011, Cancer.

[23]  Wei Liu,et al.  Dynamically accumulated dose and 4D accumulated dose for moving tumors. , 2012, Medical physics.

[24]  Daniel Gomez,et al.  Clinical Outcome of Intensity Modulated Proton Therapy for Non-Small Cell Lung Cancer , 2015 .

[25]  Joe Y. Chang,et al.  Phase 1 study of dose escalation in hypofractionated proton beam therapy for non-small cell lung cancer. , 2013, International journal of radiation oncology, biology, physics.

[26]  Z Li,et al.  Dosimetric evaluation of a novel polymer gel dosimeter for proton therapy. , 2010, Medical Physics (Lancaster).

[27]  Antony John Lomax,et al.  In the context of radiosurgery - pros and cons of rescanning as a solution for treating moving targets with scanned particle beams. , 2014, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[28]  T. Solberg,et al.  Comparing proton treatment plans of pediatric brain tumors in two pencil beam scanning nozzles with different spot sizes , 2015, Journal of applied clinical medical physics.

[29]  Icru Prescribing, recording, and reporting photon beam therapy , 1993 .

[30]  M. V. van Herk,et al.  Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy. , 2002, International journal of radiation oncology, biology, physics.

[31]  Radhe Mohan,et al.  Proton stereotactic body radiation therapy for clinically challenging cases of centrally and superiorly located stage I non-small-cell lung cancer. , 2011, International journal of radiation oncology, biology, physics.

[32]  Y. Tsunashima Verification of the clinical implementation of the respiratory gated beam delivery technique with synchrotron-based proton irradiation , 2012 .

[33]  P Boesiger,et al.  4D MR imaging of respiratory organ motion and its variability , 2007, Physics in medicine and biology.

[34]  Joe Y. Chang,et al.  4D Proton treatment planning strategy for mobile lung tumors. , 2007, International journal of radiation oncology, biology, physics.

[35]  A. Lomax,et al.  Intensity modulated proton therapy and its sensitivity to treatment uncertainties 1: the potential effects of calculational uncertainties , 2008, Physics in medicine and biology.

[36]  R. Mohan,et al.  Perturbation of water‐equivalent thickness as a surrogate for respiratory motion in proton therapy , 2016, Journal of applied clinical medical physics.

[37]  Shinichi Shimizu,et al.  Optimization and evaluation of multiple gating beam delivery in a synchrotron-based proton beam scanning system using a real-time imaging technique. , 2016, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[38]  Radhe Mohan,et al.  Robust optimization of intensity modulated proton therapy. , 2012, Medical physics.

[39]  D Robertson,et al.  Intensity modulated proton therapy treatment planning using single-field optimization: the impact of monitor unit constraints on plan quality. , 2010, Medical physics.

[40]  Joe Y. Chang,et al.  Improving radiation conformality in the treatment of non-small cell lung cancer. , 2010, Seminars in radiation oncology.

[41]  A J Lomax,et al.  Intensity modulated proton therapy and its sensitivity to treatment uncertainties 2: the potential effects of inter-fraction and inter-field motions , 2008, Physics in medicine and biology.

[42]  B. Jones,et al.  Proton and Charged Particle Radiotherapy , 2010 .

[43]  Wei Liu,et al.  Influence of robust optimization in intensity-modulated proton therapy with different dose delivery techniques. , 2012, Medical physics.

[44]  George Starkschall,et al.  Assessing respiration-induced tumor motion and internal target volume using four-dimensional computed tomography for radiotherapy of lung cancer. , 2007, International journal of radiation oncology, biology, physics.

[45]  Xiaodong Zhang,et al.  Towards Effective and Efficient Patient-Specific Quality Assurance for Spot Scanning Proton Therapy , 2015, Cancers.

[46]  Joe Y. Chang,et al.  Clinical controversies: proton therapy for thoracic tumors. , 2013, Seminars in radiation oncology.

[47]  Christoph Bert,et al.  Quantification of interplay effects of scanned particle beams and moving targets , 2008, Physics in medicine and biology.

[48]  S Dowdell,et al.  Interplay effects in proton scanning for lung: a 4D Monte Carlo study assessing the impact of tumor and beam delivery parameters , 2013, Physics in medicine and biology.

[49]  Dirk Boye,et al.  Adequate margin definition for scanned particle therapy in the incidence of intrafractional motion. , 2013, Physics in medicine and biology.

[50]  Heng Li,et al.  On the interplay effects with proton scanning beams in stage III lung cancer. , 2014, Medical physics.

[51]  Frederik Wenz,et al.  Deep Inspiration Breath Hold-Based Radiation Therapy: A Clinical Review. , 2016, International journal of radiation oncology, biology, physics.

[52]  D Meer,et al.  A study on repainting strategies for treating moderately moving targets with proton pencil beam scanning at the new Gantry 2 at PSI , 2010, Physics in medicine and biology.

[53]  S. Mori,et al.  Systematic evaluation of four-dimensional hybrid depth scanning for carbon-ion lung therapy. , 2013, Medical physics.

[54]  Martin Stuschke,et al.  Potentials of robust intensity modulated scanning proton plans for locally advanced lung cancer in comparison to intensity modulated photon plans. , 2012, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[55]  H. Paganetti,et al.  Four-dimensional Monte Carlo simulations demonstrating how the extent of intensity-modulation impacts motion effects in proton therapy lung treatments. , 2013, Medical physics.

[56]  Marco Durante,et al.  Motion mitigation in intensity modulated particle therapy by internal target volumes covering range changes. , 2012, Medical physics.

[57]  62 , 2018, The Devil's Fork.

[58]  M. Phillips,et al.  Effects of respiratory motion on dose uniformity with a charged particle scanning method. , 1992, Physics in medicine and biology.

[59]  A J Lomax,et al.  Experimental verification of motion mitigation of discrete proton spot scanning by re-scanning , 2013, Physics in medicine and biology.

[60]  Christian Graeff,et al.  Motion mitigation in scanned ion beam therapy through 4D-optimization. , 2014, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[61]  James Shackleford,et al.  Motion interplay as a function of patient parameters and spot size in spot scanning proton therapy for lung cancer. , 2013, International journal of radiation oncology, biology, physics.

[62]  M. V. van Herk,et al.  The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy. , 2000, International journal of radiation oncology, biology, physics.

[63]  A J Lomax,et al.  Respiratory liver motion estimation and its effect on scanned proton beam therapy , 2012, Physics in medicine and biology.

[64]  Daniel Richter,et al.  Special report: Workshop on 4D-treatment planning in actively scanned particle therapy-Recommendations, technical challenges, and future research directions. , 2010, Medical physics.

[65]  S. Hahn,et al.  Proton pencil beam scanning for mediastinal lymphoma: treatment planning and robustness assessment , 2016, Acta oncologica.

[66]  Christoph Bert,et al.  Respiratory motion management in particle therapy. , 2010, Medical physics.

[67]  Holly Ning,et al.  Intensity-modulated proton therapy for elective nodal irradiation and involved-field radiation in the definitive treatment of locally advanced non-small-cell lung cancer: a dosimetric study. , 2015, Clinical lung cancer.

[68]  Tonghai Liu,et al.  Comparison of the planning target volume based on three-dimensional CT and four-dimensional CT images of non-small-cell lung cancer. , 2011, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[69]  Heng Li,et al.  Clinical implementation of intensity modulated proton therapy for thoracic malignancies. , 2014, International journal of radiation oncology, biology, physics.

[70]  Li Liao,et al.  Motion-robust intensity-modulated proton therapy for distal esophageal cancer. , 2016, Medical physics.

[71]  S Both,et al.  Proton pencil beam scanning for mediastinal lymphoma: the impact of interplay between target motion and beam scanning , 2015, Physics in medicine and biology.

[72]  Radhe Mohan,et al.  Significant reduction of normal tissue dose by proton radiotherapy compared with three-dimensional conformal or intensity-modulated radiation therapy in Stage I or Stage III non-small-cell lung cancer. , 2006, International journal of radiation oncology, biology, physics.

[73]  Radhe Mohan,et al.  Adaptive/nonadaptive proton radiation planning and outcomes in a phase II trial for locally advanced non-small cell lung cancer. , 2012, International journal of radiation oncology, biology, physics.

[74]  Damien Charles Weber,et al.  Improving 4D plan quality for PBS-based liver tumour treatments by combining online image guided beam gating with rescanning , 2015, Physics in medicine and biology.

[75]  Radhe Mohan,et al.  Intensity-modulated proton therapy reduces the dose to normal tissue compared with intensity-modulated radiation therapy or passive scattering proton therapy and enables individualized radical radiotherapy for extensive stage IIIB non-small-cell lung cancer: a virtual clinical study. , 2010, International journal of radiation oncology, biology, physics.

[76]  Antje Knopf,et al.  Mapping motion from 4D-MRI to 3D-CT for use in 4D dose calculations: A technical feasibility study. , 2013, Medical physics.

[77]  Heng Li,et al.  Evaluation and mitigation of the interplay effects of intensity modulated proton therapy for lung cancer in a clinical setting. , 2014, Practical radiation oncology.

[78]  Wei Liu,et al.  Impact of respiratory motion on worst-case scenario optimized intensity modulated proton therapy for lung cancers. , 2015, Practical radiation oncology.

[79]  H. Shirato,et al.  Integration of a real-time tumor monitoring system into gated proton spot-scanning beam therapy: an initial phantom study using patient tumor trajectory data. , 2013, Medical physics.

[80]  Wei Liu,et al.  Exploratory Study of 4D versus 3D Robust Optimization in Intensity Modulated Proton Therapy for Lung Cancer. , 2016, International journal of radiation oncology, biology, physics.

[81]  Marco Durante,et al.  Residual motion mitigation in scanned carbon ion beam therapy of liver tumors using enlarged pencil beam overlap. , 2014, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[82]  A J Lomax,et al.  Comparative study of layered and volumetric rescanning for different scanning speeds of proton beam in liver patients , 2013, Physics in medicine and biology.

[83]  R. Mohan,et al.  Motion adaptive x-ray therapy: a feasibility study , 2001, Physics in medicine and biology.

[84]  Mark Oldham,et al.  Feasibility of using PRESAGE® for relative 3D dosimetry of small proton fields , 2012, Physics in medicine and biology.

[85]  Francesca Albertini,et al.  Robustness of the Voluntary Breath-Hold Approach for the Treatment of Peripheral Lung Tumors Using Hypofractionated Pencil Beam Scanning Proton Therapy. , 2016, International journal of radiation oncology, biology, physics.

[86]  M. V. van Herk,et al.  Physical aspects of a real-time tumor-tracking system for gated radiotherapy. , 2000, International journal of radiation oncology, biology, physics.

[87]  Annette Kopp-Schneider,et al.  4D-CT-based target volume definition in stereotactic radiotherapy of lung tumours: comparison with a conventional technique using individual margins. , 2009, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[88]  Lei Dong,et al.  A beam-specific planning target volume (PTV) design for proton therapy to account for setup and range uncertainties. , 2012, International journal of radiation oncology, biology, physics.

[89]  H Shirato,et al.  Preliminary analysis for integration of spot-scanning proton beam therapy and real-time imaging and gating. , 2014, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[90]  Antje-Christin Knopf,et al.  Scanned proton radiotherapy for mobile targets—the effectiveness of re-scanning in the context of different treatment planning approaches and for different motion characteristics , 2011, Physics in medicine and biology.

[91]  Christoph Bert,et al.  Simulations to design an online motion compensation system for scanned particle beams , 2006, Physics in medicine and biology.

[92]  Liyong Lin,et al.  First Clinical Investigation of Cone Beam Computed Tomography and Deformable Registration for Adaptive Proton Therapy for Lung Cancer. , 2016, International journal of radiation oncology, biology, physics.