Demonstration of Dose and Scatter Reductions for Interior Computed Tomography

With continuing developments in computed tomography (CT) technology and its increasing use of CT imaging, the ionizing radiation dose from CT is becoming a major public concern particularly for high-dose applications such as cardiac imaging. We recently proposed a novel interior tomography approach for x-ray dose reduction that is very different from all the previously proposed methods. Our method only uses the projection data for the rays passing through the desired region of interest. This method not only reduces x-ray dose but scatter as well. In this paper, we quantify the reduction in the amount of x-ray dose and scattered radiation that could be achieved using this method. Results indicate that interior tomography may reduce the x-ray dose by 18% to 58% and scatter to the detectors by 19% to 59% as the FOV is reduced from 50 to 8.6 cm.

[1]  R. Morin,et al.  Radiation dose in computed tomography of the heart. , 2003, Circulation.

[2]  F. Noo,et al.  Investigation of saddle trajectories for cardiac CT imaging in cone-beam geometry. , 2004, Physics in medicine and biology.

[3]  Ying Liu,et al.  Controlled Cardiac Computed Tomography , 2006, Int. J. Biomed. Imaging.

[4]  Jonathan G Goldin,et al.  Assessment of Coronary Artery Disease by Cardiac Computed Tomography: A Scientific Statement From the American Heart Association Committee on Cardiovascular Imaging and Intervention, Council on Cardiovascular Radiology and Intervention, and Committee on Cardiac Imaging, Council on Clinical Cardiolog , 2006, Circulation.

[5]  S. Edyvean,et al.  CT scanner dosimetry. , 1998, British Journal of Radiology.

[6]  M. Kalra,et al.  Strategies for CT radiation dose optimization. , 2004, Radiology.

[7]  Ge Wang,et al.  A knowledge-based cone-beam x-ray CT algorithm for dynamic volumetric cardiac imaging. , 2002, Medical physics.

[8]  F. Noo,et al.  A two-step Hilbert transform method for 2D image reconstruction. , 2004, Physics in medicine and biology.

[9]  Hengyong Yu,et al.  Knowledge-Based Dynamic Volumetric Cardiac Computed Tomography With Saddle Curve Trajectory , 2008, Journal of computer assisted tomography.

[10]  D. Parker Optimal short scan convolution reconstruction for fan beam CT , 1982 .

[11]  D. Brenner,et al.  Computed tomography--an increasing source of radiation exposure. , 2007, The New England journal of medicine.

[12]  Hengyong Yu,et al.  Cardiac Computed Tomography Radiation Dose Reduction Using Interior Reconstruction Algorithm With the Aorta and Vertebra as Known Information , 2009, Journal of computer assisted tomography.

[13]  M. Defrise,et al.  Tiny a priori knowledge solves the interior problem in computed tomography , 2007, 2007 IEEE Nuclear Science Symposium Conference Record.

[14]  J. Paul,et al.  Strategies for reduction of radiation dose in cardiac multislice CT , 2007, European Radiology.

[15]  M. Defrise,et al.  Solving the interior problem of computed tomography using a priori knowledge , 2008, Inverse problems.

[16]  Hiroyuki Kudo,et al.  Truncated Hilbert transform and image reconstruction from limited tomographic data , 2006 .

[17]  Andrew D. A. Maidment Medical Imaging Physics, 4th ed , 2003 .

[18]  Er-Wei Bai,et al.  A comparative study on interpolation methods for controlled cardiac CT , 2007, Int. J. Imaging Syst. Technol..

[19]  Mahadevappa Mahesh,et al.  AAPM/RSNA physics tutorial for residents: Technologic advances in multidetector CT with a focus on cardiac imaging. , 2007, Radiographics : a review publication of the Radiological Society of North America, Inc.

[20]  Hiroyuki Kudo,et al.  Image reconstruction from fan-beam projections on less than a short scan , 2002, Physics in medicine and biology.

[21]  Hengyong Yu,et al.  A General Local Reconstruction Approach Based on a Truncated Hilbert Transform , 2007, Int. J. Biomed. Imaging.

[22]  R. Dixon,et al.  Experimental validation of a versatile system of CT dosimetry using a conventional ion chamber: beyond CTDI100. , 2007, Medical physics.

[23]  Hengyong Yu,et al.  Cone-Beam Composite-Circling Scan and Exact Image Reconstruction for a Quasi-Short Object , 2007, Int. J. Biomed. Imaging.

[24]  Robert L Dixon,et al.  A new look at CT dose measurement: beyond CTDI. , 2003, Medical physics.