Modelling and analysis guidelines for slow transients. II. Controller interactions; harmonic interactions

The first part of this three-part report explains the objectives of the task force and the scope of its report (1995). The first part also provides modelling guidelines for the investigation of small-signal torsional oscillations, large-signal shaft transient stresses, turbine-blade vibrations, and fast bus transfer based on the use of digital computer time-domain simulation methods. This paper provides modelling guidelines for the analysis of controller interactions, harmonic interactions, and resonance phenomena in power systems. Sample test systems and typical time-domain simulation results for each phenomenon are also provided.

[1]  M. Szechtman,et al.  First benchmark model for HVDC control studies , 1991 .

[2]  A. S. Morched,et al.  Multi-port frequency dependent network equivalents for the EMTP , 1993 .

[3]  P. Look,et al.  A Tool for the Comprehensive Analysis of Power System Dynamic Stability , 1982, IEEE Transactions on Power Apparatus and Systems.

[4]  D. L. Dickmander,et al.  AC/DC harmonic interactions in the presence of GIC for the Quebec-New England Phase II HVDC transmission , 1994 .

[5]  Robert H. Lasseter,et al.  A study of nonlinear harmonic interaction between a single phase line-commutated converter and a power system , 1994 .

[6]  A. E. Hammad,et al.  Analysis of second harmonic instability for the Chateauguay HVDC/SVC scheme , 1992 .

[7]  Ian Dobson,et al.  Dynamic response of a thyristor controlled switched capacitor , 1994 .

[8]  D. L. Dickmander,et al.  Analysis of DC harmonics using the three-pulse model for the Intermountain Power Project HVDC transmission , 1989 .

[9]  L. Gerin-Lajoie,et al.  Basic aspects of applying SVC's to series-compensated AC transmission lines , 1990 .

[10]  D. A. Woodford Validation of Digital Simulation of DC Links , 1985, IEEE Transactions on Power Apparatus and Systems.

[11]  Robert H. Lasseter,et al.  Harmonic Interactions in Thyristor Controlled Reactor Circuits , 1989, IEEE Power Engineering Review.

[12]  M. Sublich,et al.  Impact of stray capacitance on HVDC harmonics , 1989 .

[13]  M. R. Iravani,et al.  Coordinated Static VAR Compensators and Power System Stabilizers for Damping Power System Oscillations , 1987, IEEE Transactions on Power Systems.

[14]  M. R. Iravani,et al.  Voltage control stability and dynamic interaction phenomena of static VAr compensators , 1995 .

[15]  M. R. Iravani,et al.  Computer analysis of small-signal stability of power systems including network dynamics , 1995 .

[16]  T. F. Garrity,et al.  Measurement of harmonic currents and evaluation of the DC filter performance of the New England-Hydro-Quebec Phase I HVDC project , 1989 .

[17]  H. Tyll,et al.  Dynamic Performance of a Radial Weak Power System with Multiple Static VAR Compensators , 1989, IEEE Power Engineering Review.

[18]  G. Asplund,et al.  A Three-Pulse Model of D.c. Side Harmonic Flow in HVDC Systems , 1989, IEEE Power Engineering Review.

[19]  R. Lasseter,et al.  Stability and harmonics in thyristor controlled reactors , 1989, Conference Papers Power Industry Computer Application Conference.

[20]  L. Gerin-Lajoie,et al.  Hydro-Quebec multiple SVC application control stability study , 1990 .

[21]  Magdy El-Marsafawy Use of frequency-scan techniques for subsynchronous-resonance analysis of a practical series-capacitor compensated AC network , 1983 .