The misplacement of external ventricular drain by freehand method in emergent neurosurgery.

External ventricular drain (EVD) placement is one of the most basic and common neurosurgical procedure which most was performed by young neurosurgical trainees. This study is conducted to determinate the safe and accuracy of EVD placement by freehand method. About 129 EVD placements were evaluated in this study. Eighty-three catheters (64.3%) were located in the ipsilateral frontal horn or third ventricle. The functional accuracy was 86%. Of eighteen misplaced catheters, only 4 (3.1%) catheters were nonfunctional, requiring a replacement or reposition. The higher misplaced rate was significantly observed in patients whose head CT scans revealed the lower hydrocephalus ratio (28.85%) and the smaller ventricular size (5.6 mm). Twenty-one (16.2%) new hemorrhages associated with EVD placements were observed. Using the freehand method, EVD placement is a safe and effective procedure in management of these emergent neurosurgical diseases.

[1]  C. Lind,et al.  A survey of surgical techniques for catheterising the cerebral lateral ventricles , 2008, Journal of Clinical Neuroscience.

[2]  P. Kan,et al.  Complications of intracranial pressure monitoring in children with head trauma. , 2004, Journal of neurosurgery.

[3]  J. Ghajar A guide for ventricular catheter placement. Technical note. , 1985, Journal of neurosurgery.

[4]  I. Kureshi,et al.  Comparison of percutaneous ventriculostomies and intraparenchymal monitor: a retrospective evaluation of 156 patients. , 1998, Acta neurochirurgica. Supplement.

[5]  C. Shaffrey,et al.  Efficacy of the Ghajar Guide revisited: a prospective study. , 2000, Journal of neurosurgery.

[6]  E. Wijdicks,et al.  Malplacement of Ventricular Catheters by Neurosurgeons: A Single Institution Experience , 2009, Neurocritical care.

[7]  J. Seabrook,et al.  External ventricular drains in pediatric patients* , 2009, Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies.

[8]  J. Ausman,et al.  Bedside external ventricular drain placement for the treatment of acute hydrocephalus , 2001, British journal of neurosurgery.

[9]  M. Oh,et al.  Accuracy of the freehand pass technique for ventriculostomy catheter placement: retrospective assessment using computed tomography scans. , 2008, Journal of neurosurgery.

[10]  M. Reiser,et al.  Evaluation of minimally invasive percutaneous CT-controlled ventriculostomy in patients with severe head trauma , 2004, European Radiology.

[11]  C. Lind,et al.  Ventricular catheter placement accuracy in non-stereotactic shunt surgery for hydrocephalus , 2009, Journal of Clinical Neuroscience.

[12]  R. Prat,et al.  Endoscopic biopsy of foramen of Monro and third ventricle lesions guided by frameless neuronavigation: Usefulness and limitations , 2009, Clinical Neurology and Neurosurgery.

[13]  Continuous external CSF drainage--a perpetual problem in neurosurgery. , 1998, Surgical neurology.

[14]  U. Bogdahn,et al.  Continuous-pressure controlled, external ventricular drainage for treatment of acute hydrocephalus--evaluation of risk factors. , 1992, Neurosurgery.

[15]  J. Rock,et al.  Prolonged external ventricular drainage with percutaneous long-tunnel ventriculostomies. , 1995, Journal of neurosurgery.

[16]  Nicholas Theodore,et al.  SAFETY AND ACCURACY OF BEDSIDE EXTERNAL VENTRICULAR DRAIN PLACEMENT , 2008 .

[17]  P. Gardner,et al.  Hemorrhage rates after external ventricular drain placement. , 2009, Journal of neurosurgery.