Adaptive Network-based Fuzzy Inference System for Assessment of Lower Limb Peripheral Vascular Occlusive Disease

Detecting lower limb peripheral vascular occlusive disease (PVOD) early is important for patients to prevent disabling claudication, ischaemic rest pain and gangrene. According to previous research, the pulse timing and shape distortion characteristics of photoplethysmography (PPG) signals tend to increase with disease severity and calibrated amplitude decreases with vascular diseases. However, this is not a reliable method of evaluating the condition of PVOD because of noise effect. In this paper, an adaptive network-based fuzzy inference system (ANFIS) is proposed to assess lower limb PVOD based on PPG signals. PPG signals are non-invasively recorded from the right and left sides at the big toe sites from twenty subjects, including normal condition (Nor), lower-grade disease (LG), and higher-grade disease (HG) groups. The number of each group is 10, 8 and 2 respectively, and the ages ranged from 24 to 65 years. With the time-domain technique, the parameters for the absolute bilateral differences (right-to-left side of foot) in pulse delay and amplitude were extracted for analyzing ANFIS. The results indicated that ANFIS based on three timing parameters base bilateral differences, including ΔPTTf and ΔPTTp, and ΔRT has a high rate and noise tolerance of PVOD assessment.

[1]  Chao-Lin Kuo Design of an Adaptive Fuzzy Sliding-Mode Controller for Chaos Synchronization , 2007 .

[2]  I Oliva,et al.  [Diagnosis of obliterating arteriosclerosis of the lower limbs using pulse-wave analysis]. , 1976, Fysiatricky a reumatologicky vestnik.

[3]  Chuen-Tsai Sun,et al.  Rule-base structure identification in an adaptive-network-based fuzzy inference system , 1994, IEEE Trans. Fuzzy Syst..

[4]  Gilwon Yoon,et al.  Non-constrained Blood Pressure Monitoring Using ECG and PPG for Personal Healthcare , 2009, Journal of Medical Systems.

[5]  A. Murray,et al.  Modelling the relationship between peripheral blood pressure and blood volume pulses using linear and neural network system identification techniques , 1999, Physiological measurement.

[6]  Emil M. Petriu,et al.  Behavior-based neuro-fuzzy controller for mobile robot navigation , 2002, IMTC/2002. Proceedings of the 19th IEEE Instrumentation and Measurement Technology Conference (IEEE Cat. No.00CH37276).

[7]  Elif Derya Übeyli,et al.  AR Spectral Analysis Technique for Human PPG, ECG and EEG Signals , 2007, Journal of Medical Systems.

[8]  E Konecny,et al.  Applying Neural Network Techniques to Plethysmographic Pulse Shape Analysis , 1998, Biomedizinische Technik. Biomedical engineering.

[9]  A. Murray,et al.  Repeatability of peripheral pulse measurements on ears, fingers and toes using photoelectric plethysmography. , 1988, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[10]  M. Nitzan,et al.  The difference in pulse transit time to the toe and finger measured by photoplethysmography. , 2002, Physiological measurement.

[11]  Alan Murray,et al.  A prospective comparison of bilateral photoplethysmography versus the ankle-brachial pressure index for detecting and quantifying lower limb peripheral arterial disease. , 2008, Journal of vascular surgery.

[12]  T Togawa,et al.  Chronodiagnostic acquisition of recovery speed of heart rate under bathing stress. , 1999, Physiological measurement.

[13]  Alan Murray,et al.  Photoplethysmography detection of lower limb peripheral arterial occlusive disease: a comparison of pulse timing, amplitude and shape characteristics. , 2005, Physiological measurement.

[14]  A. Murray,et al.  Age-related changes in the characteristics of the photoplethysmographic pulse shape at various body sites , 2003, Physiological measurement.

[15]  Chia-Hung Lin,et al.  Grey clustering analysis for incipient fault diagnosis in oil-immersed transformers , 2009, Expert Syst. Appl..

[16]  I Oliva,et al.  Fourier analysis of the pulse wave in obliterating arteriosclerosis. , 1976, VASA. Zeitschrift fur Gefasskrankheiten.

[17]  John Allen Photoplethysmography and its application in clinical physiological measurement , 2007, Physiological measurement.

[18]  A Murray,et al.  Age-related changes in peripheral pulse timing characteristics at the ears, fingers and toes , 2002, Journal of Human Hypertension.

[19]  W. B. Murray,et al.  The peripheral pulse wave: Information overlooked , 1996, Journal of clinical monitoring.

[20]  M. Sherebrin,et al.  Frequency analysis of the peripheral pulse wave detected in the finger with a photoplethysmograph , 1990, IEEE Transactions on Biomedical Engineering.

[21]  Anton Vonk-Noordegraaf,et al.  Stroke volume response during exercise measured by acetylene uptake and MRI , 2007, Physiological measurement.

[22]  Chin-Teng Lin,et al.  An adaptive neural fuzzy filter and its applications , 1997, IEEE Trans. Syst. Man Cybern. Part B.

[23]  Emil M. Petriu,et al.  Behavior-based neuro-fuzzy controller for mobile robot navigation , 2003, IEEE Trans. Instrum. Meas..

[24]  Alan Murray,et al.  Variability of photoplethysmography peripheral pulse measurements at the ears, thumbs and toes , 2000 .

[25]  Y. C. Huang A New Data Mining Approach to Dissolved Gas Analysis of Oil-Insulated Power Apparatus , 2002, IEEE Power Engineering Review.

[26]  A. Stefanovska,et al.  Wavelet analysis of oscillations in the peripheral blood circulation measured by laser Doppler technique , 1999, IEEE Transactions on Biomedical Engineering.