A smart insole for monitoring plantar pressure based on the fiber Bragg grating sensing technique

The analysis of plantar pressure distribution is essential in the field of biomedical and sports-related applications. In this study, a smart insole was developed for the measurement of plantar pressure distribution and the evaluation of body postures using optical fiber Bragg grating (FBG) sensing technology. Four FBG sensors characterized by four different center Bragg wavelengths, 1528 ± 0.3, 1532 ± 0.3, 1535 ± 0.3 and 1539 ± 0.3 nm, were located at the first metatarsus, third metatarsus, fifth metatarsus and heel position, respectively. The measurement sensitivity of all the FBG sensors was 0.000412 nm/kPa, approximately. Silica gel material of modulus = 10 MPa was selected to incorporate the FBG sensors. All FBG sensors were multiplexed together with one optical fiber cable. The performance and functional properties of all FBG-based pressure sensors were calibrated in the laboratory to evaluate plantar pressure distribution. A male subject was selected for performing four tasks, namely standing in an upright position, leaning forward, squat position and forward fold. During standing tests, plantar pressure observed at the heel position was around 57% higher than that at the first and third metatarsus, while the pressure of the fifth metatarsus position presents minimal pressure, which is only 37% that of the pressure of the heel position. When the subject performs leaning forward, the squat position and forward fold posture, the first and third metatarsi show maximum pressure, while the pressure decreases at the fifth metatarsus position. However, almost zero pressure is observed at the heel position when the subject changes the body postures of leaning forward, squat and forward fold posture. The extreme pressure of the forward fold posture was 1750 kPa acquired at the first metatarsus, which is 52% and 62% higher than those at the fifth and third metatarsi, respectively. Therefore, the smart insole successfully recorded both plantar pressure distribution and body posture changes regarding the wavelength values collected by the FBG sensors.

[1]  Tao Liu,et al.  Gait Analysis Using Wearable Sensors , 2012, Sensors.

[2]  Qiao Li,et al.  In-Shoe Plantar Pressure Measurement and Analysis System Based on Fabric Pressure Sensing Array , 2010, IEEE Transactions on Information Technology in Biomedicine.

[3]  O. Bar-or,et al.  Plantar pressure differences between obese and non-obese adults: a biomechanical analysis , 2001, International Journal of Obesity.

[4]  Y.T. Zhang,et al.  Wearable medical devices for tele-home healthcare , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[5]  M. Buric,et al.  Multiplexable Low-Temperature Fiber Bragg Grating Hydrogen Sensors , 2009, IEEE Photonics Technology Letters.

[6]  Yifan Zhang,et al.  Application of FBG sensors for geotechnical health monitoring, a review of sensor design, implementation methods and packaging techniques , 2016 .

[7]  Chikamune Wada,et al.  Development of a rehabilitation support system with a shoe-type measurement device for walking , 2010, Proceedings of SICE Annual Conference 2010.

[8]  Pietro Ferraro,et al.  Design and test of a laser-based optical-fiber Bragg-grating accelerometer for seismic applications , 2008 .

[9]  Carlos A. F. Marques,et al.  Gait Shear and Plantar Pressure Monitoring: A Non-Invasive OFS Based Solution for e-Health Architectures , 2018, Sensors.

[10]  Alain Delchambre,et al.  Temperature monitoring of nuclear reactor cores with multiplexed fiber Bragg grating sensors , 2002 .

[11]  David J Margolis,et al.  Medical conditions as risk factors for pressure ulcers in an outpatient setting. , 2003, Age and ageing.

[12]  Umesh Tiwari,et al.  Fiber grating sensors in medicine: Current and emerging applications , 2011 .

[13]  Tommy H.T. Chan,et al.  Fiber Bragg grating sensors for structural health monitoring of Tsing Ma bridge : Background and experimental observation , 2006 .

[14]  Lin Zhang,et al.  In-fiber Bragg-grating temperature sensor system for medical applications , 1997 .

[15]  E Kellis,et al.  Plantar pressure distribution during barefoot standing, walking and landing in preschool boys. , 2001, Gait & posture.

[16]  R Suresh,et al.  Development of a high resolution plantar pressure monitoring pad based on fiber Bragg grating (FBG) sensors. , 2015, Technology and health care : official journal of the European Society for Engineering and Medicine.

[17]  Simona Crea,et al.  A Wireless Flexible Sensorized Insole for Gait Analysis , 2014, Sensors.

[18]  P. Bonato,et al.  Wearable sensors/systems and their impact on biomedical engineering , 2003, IEEE Engineering in Medicine and Biology Magazine.

[19]  Yangsheng Xu,et al.  Intelligent shoes for abnormal gait detection , 2008, 2008 IEEE International Conference on Robotics and Automation.

[20]  Plantar pressure analysis during tilt walking in female group , 2013 .

[21]  Yu-Chi Lee,et al.  Evaluating insole design with joint motion, plantar pressure and rating of perceived exertion measures. , 2012, Work.

[22]  S. Anand,et al.  The effect of foot arch on plantar pressure distribution during standing , 2013, Journal of medical engineering & technology.

[23]  Zamir Ahmed Abro,et al.  Development of a smart garment for monitoring body postures based on FBG and flex sensing technologies , 2018 .

[24]  Plantar pressure variation during jogging with different heel height , 2015 .

[25]  Rezaul K. Begg,et al.  Foot Plantar Pressure Measurement System: A Review , 2012, Sensors.

[26]  Michael A. Davis,et al.  Fiber grating sensors , 1997 .

[27]  Mariusz Krej,et al.  Monitoring Respiration and Cardiac Activity Using Fiber Bragg Grating-Based Sensor , 2012, IEEE Transactions on Biomedical Engineering.

[28]  Edward Sazonov,et al.  Monitoring of Posture Allocations and Activities by a Shoe-Based Wearable Sensor , 2011, IEEE Transactions on Biomedical Engineering.

[29]  S. Anand,et al.  Fibre Bragg grating sensors for plantar pressure monitoring at different walking speeds , 2014 .

[30]  Maria Fátima Domingues,et al.  Insole optical fiber Bragg grating sensors network for dynamic vertical force monitoring , 2017, Journal of biomedical optics.

[31]  Zamir Ahmed,et al.  A fiber Bragg grating based sensing platform fabricated by fused deposition modeling process for plantar pressure measurement , 2017 .

[32]  J. Hao,et al.  Combined application of FBG and PZT sensors for plantar pressure monitoring at low and high speed walking. , 2015, Technology and health care : official journal of the European Society for Engineering and Medicine.

[33]  Jung-Hoon Lee,et al.  Comparison of plantar pressure between flat and normal feet when crossing an obstacle at different heights. , 2015, Journal of Back and Musculoskeletal Rehabilitation.

[34]  Tsair-Chun Liang,et al.  Plantar Pressure Detection with Fiber Bragg Gratings Sensing System , 2016, Sensors.

[35]  Lan-Yuen Guo,et al.  Comparison of Plantar Pressure Distribution between Different Speed and Incline During Treadmill Jogging. , 2010, Journal of sports science & medicine.

[36]  Francesco Giovacchini,et al.  Development of an in-shoe pressure-sensitive device for gait analysis , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[37]  K. Taniguchi,et al.  Biometric personal identification based on gait pattern using both feet pressure change , 2008, 2008 World Automation Congress.