Experimental study of the efficiency of a SDD X‐ray detector by means of PIXE spectra

The efficiency of a silicon drift detector with ultrathin window was studied for energies between 0.27 and 25 keV. Experimental values of the X-ray yields from samples of known stoichiometry were obtained by impact of 2 MeV protons. By using theoretical calculations of these yields the relative efficiency of the detector was evaluated. The results are compared with efficiency values obtained from the window transmission and the detector quantum efficiency. A quantitative analysis of a particle induced X-ray emission spectrum for a reference sample was performed in order to evaluate the consistency of the data presented in this work. Copyright © 2013 John Wiley & Sons, Ltd.

[1]  Frank Scholze,et al.  Low energy response of silicon pn-junction detector , 1996 .

[2]  J. Campbell Fluorescence yields and Coster–Kronig probabilities for the atomic L subshells , 2003 .

[3]  S. Limandri,et al.  Structure of the Pb, Bi, Th, and U M x-ray spectra , 2008 .

[4]  S. Reed,et al.  Escape peaks and internal fluorescence in X-ray spectra recorded with lithium drifted silicon detectors , 1972 .

[5]  Pavel Rehak,et al.  Semiconductor drift chamber: an application of a novel charge transport scheme , 1984 .

[6]  D M Usher,et al.  Sodium ion migration in glass on electron beam irradiation , 1981 .

[7]  Frank Scholze,et al.  Characterization of a windowless Si(Li) detector in the photon energy range 0.1-5 keV , 1994 .

[8]  D. Joy Fundamental Constants for Quantitative X-ray Microanalysis. , 2001, Microscopy and microanalysis : the official journal of Microscopy Society of America, Microbeam Analysis Society, Microscopical Society of Canada.

[9]  Karen J. Olsen,et al.  X-Ray Form Factor, Attenuation and Scattering Tables (version 2.0) , 2003 .

[10]  F. Scholze,et al.  The Determination of the Efficiency of Energy Dispersive X-Ray Spectrometers by a New Reference Material , 2006, Microscopy and Microanalysis.

[11]  U. Lehnert,et al.  Efficiency calibration of a Si(Li) detector in the low-energy region using electron bremsstrahlung , 1997 .

[12]  M. Garg,et al.  Comparison of experimental and theoretical efficiency of HPGe X-ray detector , 2008 .

[13]  Peter Lechner,et al.  Ultrathin entrance windows for silicon drift detectors , 1997 .

[14]  Heike Soltau,et al.  Expanding the detection efficiency of silicon drift detectors , 2010 .

[15]  John L. Campbell,et al.  The Guelph PIXE software package III: Alternative proton database , 2000 .

[16]  F. Scholze,et al.  Detection efficiency of energy-dispersive detectors with low-energy windows , 2005 .

[17]  L. Tribedi,et al.  Efficiency determination of a Si(Li) X-ray detector in the energy range 1–20 keV , 1992 .

[18]  S. Limandri,et al.  Experimental Method to Determine the Absolute Efficiency Curve of a Wavelength Dispersive Spectrometer , 2008, Microscopy and Microanalysis.