Interactive fast spin‐echo imaging

It is shown that a spin‐echo sequence may be used to acquire T2‐weighted, high‐resolution, high‐SNR sections at quasi‐real‐time frame rates for interactive, diagnostic imaging. A single‐shot fast spin‐echo sequence was designed which employs driven equilibrium to realign transverse magnetization remaining at the final spin echo. Driven equilibrium is shown to improve T2 contrast at a given TR, or conversely to reduce TR by approximately 1000 msec and thus increase temporal resolution while maintaining a given level of contrast. Wiener demodulation of k‐space data prior to reconstruction is shown to reduce blurring caused by T2‐decay while constraining noise often associated with other inverse filters. Images are continuously acquired, reconstructed, and displayed at rates of one image every one to two seconds, while section position and contrast may be altered interactively. The clinical utility of this method is demonstrated with applications to dynamic pelvic floor imaging and interactive obstetric imaging. Magn Reson Med 44:339–348, 2000. © 2000 Wiley‐Liss, Inc.

[1]  O Ernst,et al.  Breath-hold MR cholangiopancreatography using a HASTE sequence: comparison of single-slice and multislice acquisition techniques. , 1997, AJR. American journal of roentgenology.

[2]  G Wang,et al.  Longitudinal image deblurring in spiral CT. , 1994, Radiology.

[3]  J N Lee,et al.  A modified saturation‐recovery approximation for multiple spin‐echo pulse sequences , 1986, Magnetic resonance in medicine.

[4]  J Hennig,et al.  RARE imaging: A fast imaging method for clinical MR , 1986, Magnetic resonance in medicine.

[5]  J. Hennig Multiecho imaging sequences with low refocusing flip angles , 1988 .

[6]  R. Murakami,et al.  MR sialography using half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequences. , 1998, AJNR. American journal of neuroradiology.

[7]  M Heller,et al.  Kinematic MR imaging of the ankle — initial results with ultra-fast sequence imaging , 1997, Acta radiologica.

[8]  K Tsuchiya,et al.  Surface anatomy MR scanning of the brain using HASTE sequences. , 1996, AJR. American journal of roentgenology.

[9]  M Takahashi,et al.  Characterization of focal liver lesions with half‐Fourier acquisition single‐shot turbo‐spin‐echo (HASTE) and inversion recovery (IR)‐HASTE sequences , 1998, Journal of magnetic resonance imaging : JMRI.

[10]  A F Gmitro,et al.  A real‐time reconstruction system for magnetic resonance imaging , 1996, Magnetic resonance in medicine.

[11]  J N Lee,et al.  MR fluoroscopy: Technical feasibility , 1988, Magnetic resonance in medicine.

[12]  C M van Uijen,et al.  Driven‐equilibrium radiofrequency pulses in NMR imaging , 1984, Magnetic resonance in medicine.

[13]  C J Hardy,et al.  Real‐time interactive MRI on a conventional scanner , 1997, Magnetic resonance in medicine.

[14]  J Listerud,et al.  First principles of fast spin echo. , 1992, Magnetic resonance quarterly.

[15]  F A Jolesz,et al.  Contrast manipulation and artifact assessment of 2D and 3D RARE sequences. , 1990, Magnetic resonance imaging.

[16]  S J Riederer,et al.  Cardiac magnetic resonance fluoroscopy , 1996, Magnetic resonance in medicine.

[17]  R F Busse,et al.  Interactive three‐point localization of double‐oblique sections using MR fluoroscopy , 1999, Magnetic resonance in medicine.

[18]  D. Agard,et al.  Fluorescence microscopy in three dimensions. , 1989, Methods in cell biology.

[19]  M Takahashi,et al.  The value of MR urography that uses HASTE sequences to reveal urinary tract disorders. , 1996, AJR. American journal of roentgenology.

[20]  R R Edelman,et al.  Fetal anatomy revealed with fast MR sequences. , 1996, AJR. American journal of roentgenology.

[21]  C. Beaulieu,et al.  Reduction of ringing and blurring artifacts in fast spin‐echo imaging , 1993, Journal of magnetic resonance imaging : JMRI.

[22]  R. Semelka,et al.  MR imaging of the small bowel using the HASTE sequence. , 1998, AJR. American journal of roentgenology.

[23]  C. M. J. Van Uijen,et al.  Driven‐equilibrium radiofrequency pulses in NMR imaging , 1984, Magnetic resonance in medicine.

[24]  D. Feinberg,et al.  Halving MR imaging time by conjugation: demonstration at 3.5 kG. , 1986, Radiology.

[25]  D M Spielman,et al.  Magnetic resonance fluoroscopy using spirals with variable sampling densities , 1995, Magnetic resonance in medicine.

[26]  A L Baert,et al.  T2-weighted MR imaging of the uterus: comparison of optimized fast spin-echo and HASTE sequences with conventional fast spin-echo sequences. , 1998, AJR. American journal of roentgenology.

[27]  M Takahashi,et al.  Invited. Ultrafast T2‐weighted imaging of the abdomen and pelvis: Use of single shot fast spin‐echo imaging , 1998, Journal of magnetic resonance imaging : JMRI.

[28]  D. Noll,et al.  Homodyne detection in magnetic resonance imaging. , 1991, IEEE transactions on medical imaging.