MRI confirmation of accuracy of freehand placement of mesial temporal lobe depth electrodes in the investigation of intractable epilepsy.

Stereotactic techniques are commonly used to place intracerebral depth electrodes. We placed 15 depth electrodes (9R, 6L) freehand, orthogonally into temporal lobes in 12 patients undergoing monitoring with subdural strip electrodes in the evaluation of their intractable epilepsy. Coronal MRI was performed with the electrodes in place. The mean distance from the closest depth electrode contact to the hippocampus was 0.8 mm (range 0-5 mm). In 11 instances the closest contact was either within or making contact with the hippocampus, and in another three it was within 3 mm. For 13 electrodes, the most distal contact was the closest to the hippocampus, for two the penultimate contact was closest. There were no complications from electrode placement. Ictal onset was mesial temporal in 11 patients and frontal in one. Temporal onset was detectable in the depth electrode in each case, usually simultaneously with the onset in the subdural electrode although often the discharge was better developed in the depth electrode. We conclude that freehand placement of depth electrodes orthogonally into the temporal lobe can achieve a degree of accuracy sufficient to localize seizure onset in the mesial temporal lobe.

[1]  I. Germano,et al.  Frameless stereotaxy for surgery of the epilepsies: preliminary experience. Technical note. , 1994, Journal of neurosurgery.

[2]  L F Quesney,et al.  Depth electrode investigations in patients with bitemporal epileptiform abnormalities , 1989, Annals of neurology.

[3]  R. Mattson,et al.  Characteristics of medial temporal lobe epilepsy: II. Interictal and ictal scalp electroencephalography, neuropsychological testing, neuroimaging, surgical results, and pathology , 1993, Annals of neurology.

[4]  H. Shimizu,et al.  Mesial temporal subdural electrode as a substitute for depth electrode. , 1992, Surgical neurology.

[5]  G. Walker,et al.  Chronic subdural strip electrode recordings for difficult epileptic problems , 1988 .

[6]  A. Olivier Depth electrode implantation at the Montreal Neurological Institute and Hospital , 1987 .

[7]  S. Spencer,et al.  Combined depth and subdural electrode investigation in uncontrolled epilepsy , 1990, Neurology.

[8]  W D Tobler,et al.  Implantation of intracerebral depth electrodes for monitoring seizures using the Pelorus stereotactic system guided by magnetic resonance imaging. Technical note. , 1993, Journal of neurosurgery.

[9]  G W Somes,et al.  Long-term ictal monitoring with subdural strip electrodes: prognostic factors for selecting temporal lobectomy candidates. , 1992, Journal of neurosurgery.

[10]  G. Ojemann,et al.  Subdural strip electrodes for localizing epileptogenic foci. , 1984, Journal of neurosurgery.

[11]  D. Spencer,et al.  The localizing value of depth electroencephalography in 32 patients with refractory epilepsy , 1982, Annals of neurology.

[12]  J K Vries,et al.  Stereotactic implantation of deep brain electrodes using computed tomography. , 1983, Neurosurgery.

[13]  D R Fish,et al.  Stereotactic insertion of intracerebral electrodes in the investigation of epilepsy. , 1993, British journal of neurosurgery.

[14]  M. Sperling,et al.  Magnetic Resonance Imaging in Localization of EEG Depth Electrodes for Seizure Monitoring , 1992, Epilepsia.

[15]  P. Pillay,et al.  MRI-guided stereotactic placement of depth electrodes in temporal lobe epilepsy. , 1992, British journal of neurosurgery.

[16]  M R Sperling,et al.  Comparison of depth and subdural electrodes in recording temporal lobe seizures , 1989, Neurology.