Improving precision of manual hydrodynamic injection in capillary electrophoresis with contactless conductivity detection.

Reproducible injection in capillary electrophoresis has been difficult to achieve with manual injection techniques using simple injection devices, such as gravity injection (siphoning) or hydrodynamic sample splitting. We demonstrate that the injection reproducibility can be improved using very simple means. With hydrodynamic sample splitter, a passive micro-metering valve can be inserted in-line to regulate the sample flow rate through the splitter interface. A significant improvement of both reproducibility and repeatability was achieved. The reproducibility of RSD of the peak areas improved from 25.4% to 4.4%, while the repeatability was below 4.1% when micro-metering valve was used. Additional simple correction that can be used to further improve the variability of injected sample volumes in any hydrodynamic injection mode in CE with conductivity detection was proposed and verified. The measured EOF peak can serve as a simple indicator of the injected volume and can be effectively used for additional correction. By a linear function between the injection volume and the peak area of the EOF, the RSD values of peak areas for both manual gravity injection and hydrodynamic sample splitter were further improved below 2% RSD. The linearity of the calibration curve was also significantly improved. The proposed correction works even with slight differences in matrix composition, as demonstrated on the analysis aqueous soil extract of model mixture of five nerve agent degradation products.

[1]  K. Tsukagoshi,et al.  Capillary Electrophoresis-Chemiluminescence Detection System Equipped with a Consecutive Sample-Injection Device , 2004, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[2]  Beat Müller,et al.  Capillary electrophoresis with contactless conductivity detection coupled to a sequential injection analysis manifold for extended automated monitoring applications. , 2010, Analytica chimica acta.

[3]  G. Guiochon,et al.  INTERNAL STANDARDIZATION TECHNIQUE FOR CAPILLARY ZONE ELECTROPHORESIS , 1991 .

[4]  M. Breadmore,et al.  Identification of inorganic ions in post‐blast explosive residues using portable CE instrumentation and capacitively coupled contactless conductivity detection , 2008, Electrophoresis.

[5]  Thomas Kappes,et al.  Field-portable capillary electrophoresis instrument with potentiometric and amperometric detection , 1999 .

[6]  Andrus Seiman,et al.  A portable capillary electropherograph equipped with a cross‐sampler and a contactless‐conductivity detector for the detection of the degradation products of chemical warfare agents in soil extracts , 2009, Electrophoresis.

[7]  P. Hauser,et al.  Determination of nerve agent degradation products by capillary electrophoresis using field-amplified sample stacking injection with the electroosmotic flow pump and contactless conductivity detection. , 2009, Journal of chromatography. A.

[8]  Sam F. Y. Li,et al.  Portable capillary electrophoresis system with potential gradient detection for separation of DNA fragments , 2005, Electrophoresis.

[9]  P. Hauser,et al.  Ion-pair liquid-liquid-liquid microextraction of nerve agent degradation products followed by capillary electrophoresis with contactless conductivity detection. , 2008, Journal of chromatography. A.

[10]  A. Cifuentes,et al.  Measuring the length of hydrodynamically injected plugs in capillary electrophoresis using the electrical current monitoring , 2006, Electrophoresis.

[11]  M. Vaher,et al.  Analysis of the degradation products of chemical warfare agents using a portable capillary electrophoresis instrument with various sample injection devices , 2010 .

[12]  H. Wätzig,et al.  Precise quantitative capillary electrophoresis: Methodological and instrumental aspects , 1993 .

[13]  Richard N. Zare,et al.  Bias in quantitative capillary zone electrophoresis caused by electrokinetic sample injection , 1988 .

[14]  P. Hauser,et al.  Analysis of electroplating baths by capillary electrophoresis with high voltage contactless conductivity detection , 2006 .

[15]  M. Sepaniak,et al.  Parameters affecting reproducibility in capillary electrophoresis , 2000, Electrophoresis.

[16]  Paul R. Haddad,et al.  New Fully Portable Instrument for the Versatile Determination of Cations and Anions by Capillary Electrophoresis with Contactless Conductivity Detection , 2007 .

[17]  Rosanne M Guijt,et al.  Identification of inorganic improvised explosive devices by analysis of postblast residues using portable capillary electrophoresis instrumentation and indirect photometric detection with a light-emitting diode. , 2007, Analytical chemistry.

[18]  Sam F. Y. Li,et al.  Simultaneous determination of low‐molecular‐weight organic acids and chlorinated acid herbicides in environmental water by a portable CE system with contactless conductivity detection , 2007, Electrophoresis.

[19]  B. X. Mayer,et al.  How to increase precision in capillary electrophoresis. , 2001, Journal of chromatography. A.

[20]  Hua‐tao Feng,et al.  On‐chip potential gradient detection with a portable capillary electrophoresis system , 2004, Electrophoresis.

[21]  Thomas Kappes,et al.  Portable capillary electrophoresis instrument with potentiometric detection , 1998 .

[22]  Martin Pumera,et al.  Measurements of chemical warfare agent degradation products using an electrophoresis microchip with contactless conductivity detector. , 2002, Analytical chemistry.

[23]  F. Everaerts,et al.  Quantitative analysis in capillary zone electrophoresis with conductivity and indirect UV detection , 1991 .

[24]  E. Yeung,et al.  Compensating for instrumental and sampling biases accompanying electrokinetic injection in capillary zone electrophoresis , 1992 .