Effects of different contacting pressure on the transfer function between finger photoplethysmographic and radial blood pressure waveforms

Background: The blood pressure (BP) waveform is suggested to reflect the whole-body blood supply distribution, but its non-invasive assessment is not sufficiently user friendly for practical applications. The present authors studied the correlation between BP and photo-plethysmography (PPG) waveforms, with the aim of determining the optimal range for contact pressure stimulation (PS) to produce a reliable transfer function in their harmonic parameters. Methods: Finger PPG and radial-artery BP signals were measured simultaneously and non-invasively on healthy volunteers (n = 45). PS of 0–200 mmHg was applied to the finger, and 1 min data sequences were recorded. In frequency-domain analysis, linear regression was applied to the calculated amplitude ratios or the first five harmonics between BP and PPG waveforms. Results: In the 60 mmHg-PS group, the BP–PPG regression of amplitude ratios was highest, and the agreements between them were also the best verified by Bland–Altman analysis. Conclusion: In the present study, frequency-domain analysis was performed to study the correlation between BP and PPG waveforms. Differences in pressure-induced-vasodilation responses underlie the different BP-PPG waveform correlations obtained by applying different PSs. The non-invasively derived PPG parameters might help to provide an easier method to acquire the radial-artery BP waveform, and hence broaden the application of BP waveform analysis.

[1]  J L Saumet,et al.  Dynamics of local pressure-induced cutaneous vasodilation in the human hand. , 2001, Microvascular research.

[2]  Wei-Chen Hsu,et al.  Microcirculatory changes by laser Doppler after infrared heating over acupuncture points--relevance to moxibustion. , 2009, Photomedicine and laser surgery.

[3]  Ming-Yie Jan,et al.  Effects of acupuncture at the Hoku acupoint on the pulsatile laser Doppler signal at the heartbeat frequency , 2009, Lasers in Medical Science.

[4]  Hsien-Tsai Wu,et al.  Association of risk factors with increased pulse wave velocity detected by a novel method using dual-channel photoplethysmography. , 2005, American journal of hypertension.

[5]  Y. Wan,et al.  Effect of acupuncture at Hsien-Ku (St-43) on the pulse spectrum and a discussion of the evidence for the frequency structure of Chinese medicine. , 2000, The American journal of Chinese medicine.

[6]  Ming-Yie Jan,et al.  Connection between RR-interval length and the pulsatile microcirculatory flow. , 2008, Physiological measurement.

[7]  Kirk H. Shelley,et al.  How Does the Plethysmogram Derived from the Pulse Oximeter Relate to Arterial Blood Pressure in Coronary Artery Bypass Graft Patients? , 2001, Anesthesia and analgesia.

[8]  Wei-Chen Hsu,et al.  Differences in the microcirculatory effects of local skin surface contact pressure stimulation between acupoints and nonacupoints: possible relevance to acupressure , 2010, Physiological measurement.

[9]  X. Teng,et al.  The effect of contacting force on photoplethysmographic signals , 2004, Physiological measurement.

[10]  Wen-Miin Liang,et al.  A Novel Noninvasive Measurement Technique for Analyzing the Pressure Pulse Waveform of the Radial Artery , 2008, IEEE Transactions on Biomedical Engineering.

[11]  H Hsiu,et al.  The possible role of arterial radial vibration in heart rate and blood pressure matching , 2008, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[12]  W K Wang,et al.  Alteration of pulse in human subjects by three Chinese herbs. , 1994, The American journal of Chinese medicine.

[13]  A. Murray,et al.  Modelling the relationship between peripheral blood pressure and blood volume pulses using linear and neural network system identification techniques , 1999, Physiological measurement.

[14]  Wei-Chen Hsu,et al.  Microcirculatory effect of different skin contacting pressures around the blood pressure , 2008, Physiological measurement.

[15]  H Hsiu,et al.  Effects of whole-body mechanical stimulation at double the heart rate on the blood pressure waveform in rats. , 2006, Physiological measurement.

[16]  Nigel H. Lovell,et al.  Spectral Analysis of Finger Photoplethysmographic Waveform Variability in a Model of Mild to Moderate Haemorrhage , 2008, Journal of Clinical Monitoring and Computing.

[17]  M. Nitzan,et al.  Verylow frequency variability in arterial blood pressure and blood volume pulse , 2006, Medical & Biological Engineering & Computing.

[18]  Kirk H. Shelley,et al.  The relationship between the photoplethysmographic waveform and systemic vascular resistance , 2007, Journal of Clinical Monitoring and Computing.

[19]  W. Nichols Clinical measurement of arterial stiffness obtained from noninvasive pressure waveforms. , 2005, American journal of hypertension.