A decade of cloud‐to‐ground lightning in Canada: 1999–2008. Part 1: Flash density and occurrence

Abstract Flash density and occurrence features for more than 23.5 million cloud‐to‐ground (CG) lightning flashes detected by the Canadian Lightning Detection Network (CLDN) from 1999 to 2008 are analyzed on 20 × 20 km equal area squares over Canada. This study was done to update an analysis performed in 2002 with just three years of data. Flashes were detected throughout the year, and distinct geographic differences in flash density and lightning occurrence were observed. The shape and locations of large scale patterns of lightning occurrence remained almost the same, although some details were different. Flash density maxima occurred at the same locations as found previously: the Swan Hills and Foothills of Alberta, southeastern Saskatchewan, southwestern Manitoba and southwestern Ontario. A region of greater lightning occurrence but relatively low flash density south of Nova Scotia occurred at the same location as reported previously. New areas of higher flash density occurred along the US border with northwestern Ontario and southern Quebec. These appear to be northward extensions of higher flash density seen in the previous study. The greatest average CG flash density was 2.8 flash km−2 y−1 in southwestern Ontario, where the greatest single‐year flash density (10.3 flash km−2 y−1) also occurred. Prominent flash density minima occurred east of the Continental Divide in Alberta and over the Niagara Escarpment in southern Ontario. Lightning activity is seen to be highly influenced by the length of the season, proximity to cold water bodies and elevation. The diurnal heating and cooling cycle exerted the main control over lightning occurrence over most land areas; however, storm translation and transient dynamic features complicated the time pattern of lightning production. A large portion of the southern Prairie Provinces experienced more than 50% of flashes between 22:30 and 10:30 local solar time. The duration of lightning over a 20 × 20 km square at most locations in Canada is 5–10 h y−1, although the duration exceeded 15 h y−1 over extreme southwestern Ontario. Lightning occurred on 15–30 days each year, on average, over most of the interior of the country. The greatest number of days with lightning in a single year was 47 in the Alberta foothills and 50 in southwestern Ontario. Beginning and ending dates of the lightning season show that the season length decreases from north to south; however, there are considerable east‐west differences between regions. The season is nearly year‐round in the Pacific coastal region, southern Nova Scotia, southern Newfoundland and offshore.

[1]  Brian Mills,et al.  Assessment of lightning-related damage and disruption in Canada , 2010 .

[2]  R. Orville,et al.  Lightning Ground Flash Measurements over the Contiguous United States: 1995–97 , 1999 .

[3]  S. Ladochy,et al.  THUNDERSTORM CLIMATOLOGY BASED ON LIGHTNING DETECTOR DATA, MANITOBA, CANADA , 1989 .

[4]  M. Flannigan,et al.  Lightning and lightning fire, central cordillera, Canada , 2002 .

[5]  V. Rakov,et al.  Lightning: Physics and Effects , 2007 .

[6]  D. Sills Lake and land breezes in southwestern Ontario: Observations, analyses and numerical modelling , 1998 .

[7]  William R. Burrows,et al.  Lightning occurrence patterns over Canada and adjacent United States from lightning detection network observations , 2002 .

[8]  Kenneth L. Cummins,et al.  A Combined TOA/MDF Technology Upgrade of the U.S. National Lightning Detection Network , 1998 .

[9]  William R. Burrows,et al.  The North American Lightning Detection Network (NALDN)—First Results: 1998–2000 , 2002 .

[10]  K.L. Cummins,et al.  An Overview of Lightning Locating Systems: History, Techniques, and Data Uses, With an In-Depth Look at the U.S. NLDN , 2009, IEEE Transactions on Electromagnetic Compatibility.

[11]  P. Joe,et al.  Lake Breezes in Southern Ontario and Their Relation to Tornado Climatology , 2003 .

[12]  Raúl E. López,et al.  Lightning Casualties and Damages in the United States from 1959 to 1994 , 2000 .

[13]  Edward A. Johnson,et al.  Synoptic climatology of lightning-caused forest fires in subalpine and boreal forests , 1996 .

[14]  Howard B. Bluestein,et al.  Observations and theory of weather systems , 1993 .

[15]  Mike D. Flannigan,et al.  LIGHTNING-IGNITED FOREST FIRES IN NORTHWESTERN ONTARIO , 1991 .

[16]  William R. Burrows,et al.  A decade of cloud‐to‐ground lightning in Canada: 1999–2008. Part 2: Polarity, multiplicity and first‐stroke peak current , 2010 .

[17]  W. Chisholm,et al.  Lightning flash climatology in the southern great lakes region , 1996 .

[18]  J. W. Scott,et al.  Some observations and characteristics of lightning ground discharges in southern Ontario , 1988 .

[19]  Richard E. Orville,et al.  Lightning Ground Flash Density and Thunderstorm Duration in the Continental United States: 1989–96 , 1999 .

[20]  K. Hirsch,et al.  Large forest fires in Canada, 1959–1997 , 2002 .

[21]  Mike D. Flannigan,et al.  Summer convection and lightning over the Mackenzie river basin and their Impacts during 1994 and 1995 , 2002 .

[22]  R. E. López,et al.  Insured lightning-caused property damage in three Western States , 1996 .

[23]  Kenneth L. Cummins,et al.  National Lightning Detection Network (NLDN) performance in southern Arizona, Texas, and Oklahoma in 2003–2004 , 2007 .

[24]  S. Gauthier,et al.  Study of cloud‐to‐ground lightning in Quebec: 1996–2005 , 2008 .

[25]  Brenda Jones,et al.  Assessment of lightning-related fatality and injury risk in Canada , 2008 .

[26]  Kenneth L. Cummins,et al.  The U.S. National Lightning Detection NetworkTM and Applications of Cloud-to-Ground Lightning Data by Electric Power Utilities , 1998 .