Internal microstructure evolution of aluminum foams under compression

In this paper, the internal microstructure deformation of open-cell and closed-cell aluminum foams under compression was investigated by using synchrotron radiation X-ray computed tomography (SR-CT) technique and digital image analysis method. The reconstructed images were obtained by using filtered back projection algorithm based on the original images taken from SR-CT experiments. Several important parameters including cross-section porosity, total porosity and cross-section deformation were computed from the reconstructed images. The variation of these parameters provided useful evolution information of internal microstructure of aluminum foams under compression.