Single monochromator charge-coupled device (CCD) array spectroradiometers have the advantage of ease of use and speed compared with double grating instruments. Their inherently inferior stray-light rejection, however, can critically affect their accuracy in phototherapy and research-related dosimetry applications. This paper shows that without adequate correction the HR4000 (Ocean Optics Inc., Dunedin, USA) array device can overestimate the CIE erythema-weighted irradiance of common phototherapy sources and solar simulator beams by over 100%. A software stray-light correction (Ylianttila et al 2005 Photochem. Photobiol. 81 333–41), using the measured slit function of the HR4000, has been applied to spectra acquired from sources used in phototherapy and photobiology (PUVA, UV21, TL01 and solar simulator). The resulting corrected erythema-weighted irradiance measurements from the HR4000 are within 10% of those from a DM150 double grating spectroradiometer (Bentham Instruments Ltd, Reading, UK). A simple model is considered for combining estimates of measurement uncertainties. The importance of exposure bracketing to improve the dynamic range of the HR4000 is illustrated, along with the difficulty in making direct comparison of spectral values between two instruments due to wavelength scale uncertainties. Comparison with a double grating instrument in a solar simulator beam is examined here as a basis for validating CCD array device measurements. The study demonstrates that the HR4000 array spectroradiometer can provide an adequate level of accuracy for common phototherapy and photobiology applications only where a suitable stray-light correction is carefully applied and where the instrument's effective dynamic range is improved.
[1]
A. Obaton,et al.
Two procedures for the estimation of the uncertainty of spectral irradiance measurement for UV source calibration
,
2007
.
[2]
Yuqin Zong,et al.
Simple spectral stray light correction method for array spectroradiometers.
,
2006,
Applied optics.
[3]
S. Standard.
GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT
,
2006
.
[4]
Reijo Visuri,et al.
Evaluation of a Single-monochromator Diode Array Spectroradiometer for Sunbed UV-radiation Measurements¶
,
2005
.
[5]
H. Moseley,et al.
The use of diode array spectroradiometers for dosimetry in phototherapy.
,
2002,
Physics in medicine and biology.
[6]
A. Young,et al.
Ultraviolet radiation-induced erythema in human skin.
,
2002,
Methods.
[7]
B. Diffey,et al.
Guidelines for dosimetry and calibration in ultraviolet radiation therapy: a report of a British Photodermatology Group workshop
,
2002,
The British journal of dermatology.
[8]
S. Pye,et al.
A study of the directional response of ultraviolet radiometers: I. Practical evaluation and implications for ultraviolet measurement standards.
,
2000,
Physics in medicine and biology.
[9]
P. Gibson.
4 – Techniques for Spectroradiometry and Broadband Radiometry
,
1989
.