High efficiency particulate air (HEPA) filters are routinely used in DOE nuclear containment activities. The Nuclear Air Cleaning Handbook (NACH) stipulates that air cleaning devices and equipment used in DOE nuclear applications must meet the American Society of Mechanical Engineers (ASME) Code on Nuclear Air and Gas Treatment (AG-1) standard. This testing activity evaluates two different axial flow HEPA filters, those from AG-1 Sections FC and FM. Section FM is under development and has not yet been added to AG-1 due to a lack of qualification data available for these filters. Section FC filters are axial flow units that utilize a fibrous glass filtering medium. The section FM filters utilize a similar fibrous glass medium, but also have scrim backing. The scrim-backed filters have demonstrated the ability to endure pressure impulses capable of completely destroying FC filters. The testing activities presented herein will examine the total lifetime loading for both FC and FM filters under ambient conditions and at elevated conditions of temperature and relative humidity. Results will include loading curves, penetration curves, and testing condition parameters. These testing activities have been developed through collaborations with representatives from the National Nuclear Security Administration (NNSA), DOE Office of Environmental Management (DOE-EM),more » New Mexico State University, and Mississippi State University. (authors)« less
[1]
Benjamin Y. H. Liu,et al.
Effect of Bi-Modal Aerosol Mass Loading on the Pressure Drop for Gas Cleaning Industrial Filters
,
2001
.
[2]
B. T. Chen,et al.
Performance of a TSI aerodynamic particle sizer
,
1985
.
[3]
Paxton K. Giffin,et al.
Results from Evaluation of ASME AG-1 Section FK Radial Flow HEPA Filters - 11287
,
2011
.
[4]
Paxton K. Giffin,et al.
Large-scale generic test stand for testing of multiple configurations of air filters utilizing a range of particle size distributions.
,
2012,
The Review of scientific instruments.
[5]
Da-Ren Chen,et al.
Bimodal aerosol loading and dust cake formation on air filters
,
1998
.
[6]
T. Peters,et al.
Comparison and Combination of Aerosol Size Distributions Measured with a Low Pressure Impactor, Differential Mobility Particle Sizer, Electrical Aerosol Analyzer, and Aerodynamic Particle Sizer
,
1993
.
[7]
Paxton K. Giffin,et al.
Results from Evaluation of Representative ASME AG-1 Section FK Radial Flow Dimple Pleated HEPA Filters Under Elevated Conditions - 12002
,
2012
.
[8]
C. A. Burchsted,et al.
Nuclear air cleaning handbook: Design, construction, and testing of high-efficiency air cleaning systems for nuclear application
,
1976
.