Thermal evaluation of a double glazing façade system with integrated Parallel Slat Transparent Insulation Material (PS-TIM)

Concerns over sustainability in the built environment have resulted in continuous efforts to improve the performance of glazed facade systems and hence indoor comfort and building energy conservation. An innovative facade system where parallel transparent plastic slats are sandwiched between glass panes to form a Parallel Slat Transparent Insulation Material (PS-TIM) is proposed as a strategy to effectively reduce coupled convective and radiative heat transfer between the panes of a double glazed window. This strategy increases the thermal resistance of the facade, while maintaining access to daylight. A numerical investigation of the thermal and optical performance of this facade system is presented. Detailed modelling of the thermal characteristics of a double glazed window containing PS-TIM systems was carried out for different cell aspect ratios (defined by the thickness of window air cavity and slat interval distance), slat thickness and slat properties (conductivities and emissivities) using a validated Computational Fluid Dynamic (CFD) model. The CFD predictions show that: 1) an aspect ratio of 0.35 can provide full suppression of convection; 2) the PS-TIM structure can achieve a 35–46% reduction in thermal conductance compared with the same double glazing in the absence of PS-TIM; 3) material conductivity, thickness and emissivity have a more apparent influence on small cell structures than large cell structures. In addition, a simple analysis of U-value and light transmittance at various solar incidence angles was undertaken. The results provide a better understanding of the benefits of PS-TIM in terms of energy saving and offer suggestions for the improved design of glazing facade systems.

[1]  Marilyne Andersen,et al.  Comparison between ray-tracing simulations and bi- directional transmission measurements on prismatic glazing , 2003 .

[2]  Mbc Myriam Aries,et al.  Lighting performance and electrical energy consumption of a virtual window prototype , 2014 .

[3]  Jacob C. Jonsson,et al.  Simulating Complex Window Systems using BSDF Data , 2009 .

[4]  Iason Konstantzos,et al.  View clarity index: A new metric to evaluate clarity of view through window shades , 2015 .

[5]  D. Naylor,et al.  Experimental study of free convection in a window with a heated between-panes blind , 2011 .

[6]  A. Moret Rodrigues,et al.  Solar and visible optical properties of glazing systems with venetian blinds: Numerical, experimental and blind control study , 2014 .

[7]  D. Naylor,et al.  Experimental Study of Natural Convection in a Window with a Between-Panes Venetian Blind , 2007 .

[8]  Umberto Berardi,et al.  The development of a monolithic aerogel glazed window for an energy retrofitting project , 2015 .

[9]  Yanjin Wang,et al.  Development of a Solar Control Method of the Venetian Blinds , 2015 .

[10]  Finn Harken Kristiansen,et al.  Development of windows based on highly insulating aerogel glazings , 2004 .

[11]  N. D. Kaushika,et al.  Transparent insulation characteristics of honeycomb and slat arrays , 1994 .

[12]  Philip C. Eames,et al.  A review of transparent insulation systems and the evaluation of payback period for building applications , 2007 .

[13]  Marilyne Andersen,et al.  Bi-directional transmission properties of Venetian blinds: experimental assessment compared to ray-tracing calculations , 2005 .

[14]  John L. Wright,et al.  Thermal resistance of a window with an enclosed venetian blind : Guarded heater plate measurements , 2006 .

[15]  John L. Wright,et al.  Numerical analysis of convective heat transfer in fenestration with between-the-glass louvered shades , 2009 .

[16]  Athanassios Tzempelikos,et al.  The impact of venetian blind geometry and tilt angle on view, direct light transmission and interior illuminance , 2008 .

[17]  Srinath Perera,et al.  Energy simulations of a transparent‐insulated office façade retrofit in London, UK , 2012 .

[18]  W. Beckman,et al.  Solar Engineering of Thermal Processes , 1985 .

[19]  John L. Wright,et al.  Flow visualization of natural convection in a tall, air-filled vertical cavity , 2006 .

[20]  N. Kaushika,et al.  Coupled radiative and conductive thermal transfers across transparent honeycomb insulation materials , 1996 .

[21]  N. D. Kaushika,et al.  Convective heat transfer across transparent honeycomb insulation materials , 1994 .

[22]  D. Naylor,et al.  EVALUATION OF AN APPROXIMATE METHOD FOR PREDICTING THE U VALUE OF A WINDOW WITH A BETWEEN-PANES BLIND , 2005 .

[23]  N. Kaushika,et al.  Convective effects in air layers bound by cellular honeycomb arrays , 2005 .

[24]  Arild Gustavsen,et al.  Insulating glazing units with silica aerogel granules: The impact of particle size , 2014 .

[25]  J. A. Harris,et al.  Heat transfer across corrugated sheets and honeycomb transparent insulation , 2004 .

[26]  D. Naylor,et al.  Free convective heat transfer in an enclosure with an internal louvered blind , 2008 .

[27]  Yupeng Wu,et al.  Experimental measurement and numerical simulation of the thermal performance of a double glazing system with an interstitial Venetian blind , 2016 .

[28]  Cinzia Buratti,et al.  Experimental performance evaluation of aerogel glazing systems , 2012 .

[29]  Anne Grete Hestnes,et al.  The use of transparent insulation in low energy dwellings in cold climates , 1997 .

[30]  Lucilla Badiali De Giorgi,et al.  Thermal convection in double glazed windows with structured gap , 2011 .

[31]  Seppo A. Korpela,et al.  Multicellular natural convection in a vertical slot , 1983, Journal of Fluid Mechanics.

[32]  D. Naylor,et al.  A CFD study of convection in a double glazed window with an enclosed pleated blind , 2009 .