Dose properties of a laser accelerated electron beam and prospects for clinical application.

Laser wakefield acceleration (LWFA) technology has evolved to where it should be evaluated for its potential as a future competitor to existing technology that produces electron and x-ray beams. The purpose of the present work is to investigate the dosimetric properties of an electron beam that should be achievable using existing LWFA technology, and to document the necessary improvements to make radiotherapy application for LWFA viable. This paper first qualitatively reviews the fundamental principles of LWFA and describes a potential design for a 30 cm accelerator chamber containing a gas target. Electron beam energy spectra, upon which our dose calculations are based, were obtained from a uniform energy distribution and from two-dimensional particle-in-cell (2D PIC) simulations. The 2D PIC simulation parameters are consistent with those reported by a previous LWFA experiment. According to the 2D PIC simulations, only approximately 0.3% of the LWFA electrons are emitted with an energy greater than 1 MeV. We studied only the high-energy electrons to determine their potential for clinical electron beams of central energy from 9 to 21 MeV. Each electron beam was broadened and flattened by designing a dual scattering foil system to produce a uniform beam (103%>off-axis ratio>95%) over a 25 x 25 cm2 field. An energy window (deltaE) ranging from 0.5 to 6.5 MeV was selected to study central-axis depth dose, beam flatness, and dose rate. Dose was calculated in water at a 100 cm source-to-surface distance using the EGS/BEAM Monte Carlo algorithm. Calculations showed that the beam flatness was fairly insensitive to deltaE. However, since the falloff of the depth-dose curve (R10-R90) and the dose rate both increase with deltaE, a tradeoff between minimizing (R10-R90) and maximizing dose rate is implied. If deltaE is constrained so that R10-R90 is within 0.5 cm of its value for a monoenergetic beam, the maximum practical dose rate based on 2D PIC is approximately 0.1 Gy min(-1) for a 9 MeV beam and 0.03 Gy min(-1) for a 15 MeV beam. It was concluded that current LWFA technology should allow a table-top terawatt (T3) laser to produce therapeutic electron beams that have acceptable flatness, penetration, and falloff of depth dose; however, the dose rate is still 1%-3% of that which would be acceptable, especially for higher-energy electron beams. Further progress in laser technology, e.g., increasing the pulse repetition rate or number of high energy electrons generated per pulse, is necessary to give dose rates acceptable for electron beams. Future measurements confirming dosimetric calculations are required to substantiate our results. In addition to achieving adequate dose rate, significant engineering developments are needed for this technology to compete with current electron acceleration technology. Also, the functional benefits of LWFA electron beams require further study and evaluation.

[1]  Toshiki Tajima,et al.  Laser electron accelerators for radiation medicine: a feasibility study. , 2004, Medical physics.

[2]  B Shahine,et al.  Particle in cell simulation of laser-accelerated proton beams for radiation therapy. , 2002, Medical physics.

[3]  B. Shim,et al.  Plasma Channels and Laser Pulse Tailoring for GeV Laser-Plasma Accelerators , 2002 .

[4]  K. Witte,et al.  MeV ion jets from short-pulse-laser interaction with thin foils. , 2002, Physical review letters.

[5]  Eric Esarey,et al.  Gamma-neutron activation experiments using laser wakefield accelerators , 2001 .

[6]  T. C. Sangster,et al.  Intense electron and proton beams from PetaWatt laser–matter interactions , 2000 .

[7]  François Salin,et al.  Amplifying laser pulses to the terawatt level at a 1-kilohertz repetition rate , 2000 .

[8]  Gu,et al.  Forward ion acceleration in thin films driven by a high-intensity laser , 2000, Physical review letters.

[9]  Edward B. Clark,et al.  Comment on "measurements of energetic proton transport through magnetized plasma from intense laser interactions with solids". , 2000 .

[10]  Zulfikar Najmudin,et al.  Observation of Electron Energies Beyond the Linear Dephasing Limit from a Laser-Excited Relativistic Plasma Wave , 1998 .

[11]  P. Sprangle,et al.  ELECTRON TRAPPING IN SELF-MODULATED LASER WAKEFIELDS BY RAMAN BACKSCATTER , 1997 .

[12]  B. Zackrisson,et al.  Exploration of new treatment modalities offered by high energy (up to 50 MeV) electrons and photons. , 1997, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[13]  Donald P. Umstadter,et al.  Electron Acceleration by a Laser Wakefield in a Relativistically Self-Guided Channel , 1997 .

[14]  Eric Esarey,et al.  Overview of plasma-based accelerator concepts , 1996 .

[15]  W. Mori,et al.  Spatial temporal theory of Raman forward scattering , 1996 .

[16]  Fisher,et al.  Enhanced Raman forward scattering. , 1996, Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topics.

[17]  C. Ma,et al.  BEAM: a Monte Carlo code to simulate radiotherapy treatment units. , 1995, Medical physics.

[18]  Nancy G. Leveson,et al.  An investigation of the Therac-25 accidents , 1993, Computer.

[19]  P. Sprangle,et al.  Enhanced acceleration in a self-modulated-laser wake-field accelerator. , 1993, Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topics.

[20]  Dyson,et al.  Ultrahigh-gradient acceleration of injected eletrons by laser-excited relativistic electron plasma waves. , 1993, Physical review letters.

[21]  Mora,et al.  Self-focusing and Raman scattering of laser pulses in tenuous plasmas. , 1992, Physical review letters.

[22]  D. Leavitt,et al.  Improved dose homogeneity in electron arc therapy achieved by a multiple-energy technique. , 1990, International journal of radiation oncology, biology, physics.

[23]  P R Storchi,et al.  Numerical calculation of energy deposition by broad high-energy electron beams. , 1989, Physics in medicine and biology.

[24]  Gerard Mourou,et al.  Compression of amplified chirped optical pulses , 1985 .

[25]  C. J. Karzmark,et al.  Advances in linear accelerator design for radiotherapy. , 1984, Medical physics.

[26]  T. Tajima,et al.  Laser Electron Accelerator , 1979 .

[27]  M. Brereton Classical Electrodynamics (2nd edn) , 1976 .

[28]  Michael D. Perry,et al.  Ultrahigh‐Intensity Lasers: Physics of the Extreme on a Tabletop , 1998 .

[29]  Raymond E. Meyn,et al.  Radiobiological aspects of electron beams. , 1991, Frontiers of radiation therapy and oncology.

[30]  R. K. Bull,et al.  Radiation dosimetry: Electron beams with energies between 1 and 50 MeV: ICRU Report 35; 157 pp.; 85 figures; US $23.00. , 1986 .

[31]  A. Benedetto INTRODUCTION TO RADIOLOGICAL PHYSICS AND RADIATION DOSIMETRY. , 1986 .