Clinical methods for evaluating implant framework fit.

STATEMENT OF PROBLEM Passive fit of implant-supported-prosthesis frameworks has been suggested as a prerequisite for successful long-term osseointegration. However, there are no scientific guidelines as to what is passive fit and how to achieve and measure it. PURPOSE The purpose of this article is to discuss passive fit and to review the various clinical methods that have been suggested for evaluating implant framework fit.Methods. The dental literature was reviewed to identify the clinical methods that have been used to evaluate implant framework fit. CONCLUSIONS The suggested levels of passive fit are empirical. Numerous techniques have been advocated to evaluate the prosthesis-implant interface, but none individually provides objective results. It is suggested that clinicians use a combination of the available methods to minimize misfits.

[1]  J I Nicholls,et al.  The measurement of distortion: mathematical considerations. , 1978, The Journal of prosthetic dentistry.

[2]  T Jemt,et al.  In vivo load measurements on osseointegrated implants supporting fixed or removable prostheses: a comparative pilot study. , 1991, The International journal of oral & maxillofacial implants.

[3]  M Rieger,et al.  The passive fitting implant restoration. , 1993, The Implant Society : [periodical].

[4]  I Herrmann,et al.  Osseointegrated implants for treatment of partially edentulous jaws: A 5 year prospective multicentre study , 1994 .

[5]  P J Henry,et al.  An alternative method for the production of accurate casts and occlusal records in osseointegrated implant rehabilitation. , 1987, The Journal of prosthetic dentistry.

[6]  G J Ziebert,et al.  Comparison of accuracy of multiunit one-piece castings. , 1985, The Journal of prosthetic dentistry.

[7]  P. Branemark Osseointegration and its experimental background. , 1983, The Journal of prosthetic dentistry.

[8]  N Stern,et al.  Effect of impression materials and techniques on the marginal fit of metal castings. , 1994, The Journal of prosthetic dentistry.

[9]  H R Haanaes,et al.  Implants and infections with special reference to oral bacteria. , 1990, Journal of clinical periodontology.

[10]  A Schmitt,et al.  The longitudinal clinical effectiveness of osseointegrated dental implants: the Toronto Study. Part II: The prosthetic results. , 1990, The Journal of prosthetic dentistry.

[11]  T Jemt,et al.  In vivo measurements of precision of fit involving implant-supported prostheses in the edentulous jaw. , 1996, The International journal of oral & maxillofacial implants.

[12]  R L Schneider,et al.  Fabricating low-fusing metal casts for more accurate implant prosthodontics. , 1996, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[13]  G C Michaels,et al.  Effect of prosthetic superstructure accuracy on the osteointegrated implant bone interface. , 1997, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[14]  Ross L. Taylor Laboratory Techniques for the Branemark System , 1990 .

[15]  J. Mclean,et al.  The estimation of cement film thickness by an in vivo technique , 1971, British Dental Journal.

[16]  J I Nicholls,et al.  Accuracy of replacing three tapered transfer impression copings in two elastomeric impression materials. , 1993, The International journal of prosthodontics.

[17]  B R Lang,et al.  The precision of fit at the implant prosthodontic interface. , 1997, The Journal of prosthetic dentistry.

[18]  G. Christensen Marginal fit of gold inlay castings. , 1966, The Journal of prosthetic dentistry.

[19]  J I Nicholls,et al.  Distortion in dental soldering as affected by gap distance. , 1980, The Journal of prosthetic dentistry.

[20]  N D Millington,et al.  Inaccurate fit of implant superstructures. Part 1: Stresses generated on the superstructure relative to the size of fit discrepancy. , 1995, The International journal of prosthodontics.

[21]  J I Nicholls,et al.  An evaluation of impression techniques for osseointegrated implants. , 1990, The Journal of prosthetic dentistry.

[22]  A J Voitik The Kulzer abutment luting; Kal technique. A direct assembly framework method for osseointegrated implant prostheses. , 1991, The Implant Society : [periodical].

[23]  A B Carr,et al.  The response of bone in primates around unloaded dental implants supporting prostheses with different levels of fit. , 1996, The Journal of prosthetic dentistry.

[24]  P. Branemark,et al.  Long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws. , 1990, The International journal of oral & maxillofacial implants.

[25]  T. Jemt,et al.  Accuracy of implant-supported prostheses in the edentulous jaw: analysis of precision of fit between cast gold-alloy frameworks and master casts by means of a three-dimensional photogrammetric technique. , 1995, Clinical oral implants research.

[26]  T Jemt,et al.  Prosthesis misfit and marginal bone loss in edentulous implant patients. , 1996, The International journal of oral & maxillofacial implants.

[27]  J W McCartney,et al.  Segmental framework matrix: master cast verification, corrected cast guide, and analog transfer template for implant-supported prostheses. , 1994, The Journal of prosthetic dentistry.

[28]  N. Clelland,et al.  Comparison of strains produced in a bone simulant between conventional cast and resin-luted implant frameworks. , 1997, The International journal of oral & maxillofacial implants.

[29]  M. Mills,et al.  Plaque-induced inflammation around implants. , 1992, The International journal of oral & maxillofacial implants.

[30]  Stumpel Lj rd The adhesive-corrected implant framework. , 1994 .

[31]  Takao Fusayama,et al.  Accuracy of fixed partial dentures made by various soldering techniques and one-piece casting , 1964 .

[32]  T. Jemt How do you test a cast framework fit for a full-arch fixed implant-supported prosthesis? , 1994 .

[33]  G J Ziebert,et al.  Accuracy of one-piece castings, preceramic and postceramic soldering. , 1986, The Journal of prosthetic dentistry.

[34]  A D Sones Complications with osseointegrated implants. , 1989, The Journal of prosthetic dentistry.

[35]  J I Nicholls,et al.  Three-dimensional analysis of the casting accuracy of one-piece, osseointegrated implant-retained prostheses. , 1993, The International journal of prosthodontics.

[36]  Voitik Aj The Kulzer abutment luting; Kal technique. A direct assembly framework method for osseointegrated implant prostheses. , 1991 .

[37]  R Skalak,et al.  Biomechanical considerations in osseointegrated prostheses. , 1983, The Journal of prosthetic dentistry.

[38]  B R Lang,et al.  The Periotest method: implant-supported framework precision of fit evaluation. , 1996, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[39]  J Gunne,et al.  Implant treatment in partially edentulous patients: a report on prostheses after 3 years. , 1994, The International journal of prosthodontics.

[40]  P I Brånemark,et al.  A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. , 1981, International journal of oral surgery.

[41]  G. Goll,et al.  Production of accurately fitting full-arch implant frameworks: Part I—Clinical procedures , 1992 .

[42]  Amos Gilat,et al.  Comparison of strains transferred to a bone simulant among implant overdenture bars with various levels of misfit. , 1995 .

[43]  R A Wicks,et al.  An evaluation of fit in osseointegrated implant components using torque/turn analysis. , 1994, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[44]  T Leung,et al.  Inaccurate fit of implant superstructures. Part II: Efficacy of the Preci-disc system for the correction of errors. , 1996, The International journal of prosthodontics.

[45]  S A Aquilino,et al.  Evaluation of three impression techniques for osseointegrated oral implants. , 1993, The Journal of prosthetic dentistry.

[46]  G. Murray,et al.  Design of superstructures for osseointegrated fixtures. , 1985, Swedish dental journal. Supplement.

[47]  L G Loos A fixed prosthodontic technique for mandibular osseointegrated titanium implants. , 1986, The Journal of prosthetic dentistry.

[48]  L J Stumpel The adhesive-corrected implant framework. , 1994, Journal of the California Dental Association.

[49]  L Hollender,et al.  Radiographic evaluation of osseointegrated implants of the jaws. Experimental study of the influence of radiographic techniques on the measurement of the relation between the implant and bone. , 1980, Dento maxillo facial radiology.

[50]  J I Nicholls The measurement of distortion: theoretical considerations. , 1977, The Journal of prosthetic dentistry.

[51]  T. Jemt Failures and complications in 391 consecutively inserted fixed prostheses supported by Brånemark implants in edentulous jaws: a study of treatment from the time of prosthesis placement to the first annual checkup. , 1992, The International journal of oral & maxillofacial implants.

[52]  Dedmon Hw Disparity in expert opinions on size of acceptable margin openings. , 1982 .

[53]  D van Steenberghe,et al.  A study of 589 consecutive implants supporting complete fixed prostheses. Part II: Prosthetic aspects. , 1992, The Journal of prosthetic dentistry.

[54]  J. Fiorellini,et al.  Fixed implant‐supported prostheses in the edentulous maxilla. A five‐year follow‐up report. , 1994 .

[55]  M. Pharoah,et al.  An alternative holder for radiographic evaluation of tissue-integrated prostheses. , 1986, The Journal of prosthetic dentistry.

[56]  C Bessing,et al.  Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years. , 1994, The International journal of oral & maxillofacial implants.

[57]  E J Rasmussen,et al.  Alternative prosthodontic technique for tissue-integrated prostheses. , 1987, The Journal of prosthetic dentistry.