Direct electrochemistry and electrocatalysis of heme-proteins immobilized in porous carbon nanofiber/room-temperature ionic liquid composite film

Abstract The combination of porous carbon nanofiber (PCNF) and room-temperature ionic liquid (RTIL) provided a suitable microenvironment for heme-proteins to transfer electron directly. Hemoglobin, myoglobin, and cytochrome c incorporated in PCNF/RTIL films exhibited a pair of well-defined, quasi-reversible cyclic voltammetric peaks at about −0.28 V vs . SCE in pH 7.0 buffers, respectively, characteristic of the protein heme Fe(III)/Fe(II) redox couples. The cyclic voltammetry and electrochemical impedance spectroscopy were used to characterize the modified electrode. The heme/PCNF/RTIL/CHIT films were also characterized by UV–vis spectroscopy, indicating that heme-proteins in the composite film could retain its native structure. Oxygen, hydrogen peroxide, and nitrite were catalytically reduced at the heme/PCNF/RTIL/CHIT film modified electrodes, showing the potential applicability of the films as the new type of biosensors or bioreactors based on direct electrochemistry of the redox proteins.

[1]  J. Rusling Enzyme Bioelectrochemistry in Cast Biomembrane-Like Films , 1998 .

[2]  R. Hamers,et al.  Electrically Addressable Biomolecular Functionalization of Carbon Nanotube and Carbon Nanofiber Electrodes , 2004 .

[3]  Huangxian Ju,et al.  Amperometric glucose sensor based on catalytic reduction of dissolved oxygen at soluble carbon nanofiber. , 2007, Biosensors & bioelectronics.

[4]  I. Yamazaki,et al.  The mechanism of oxyperoxidase formation from ferryl peroxidase and hydrogen peroxide. , 1987, The Journal of biological chemistry.

[5]  B Wolf,et al.  Monitoring of cellular behaviour by impedance measurements on interdigitated electrode structures. , 1997, Biosensors & bioelectronics.

[6]  Jinghong Li,et al.  Composite system based on chitosan and room-temperature ionic liquid: direct electrochemistry and electrocatalysis of hemoglobin. , 2006, Biomacromolecules.

[7]  Sergei V. Kalinin,et al.  Growth of Carbon Nanofibers on Tipless Cantilevers for High Resolution Topography and Magnetic Force Imaging , 2004 .

[8]  M B Arnao,et al.  A kinetic study on the suicide inactivation of peroxidase by hydrogen peroxide. , 1990, Biochimica et biophysica acta.

[9]  E. Laviron The use of linear potential sweep voltammetry and of a.c. voltammetry for the study of the surface electrochemical reaction of strongly adsorbed systems and of redox modified electrodes , 1979 .

[10]  Jinghong Li,et al.  Carbon nanofiber-based composites for the construction of mediator-free biosensors. , 2008, Biosensors & bioelectronics.

[11]  Xiaoying He,et al.  Direct electrochemistry of hemoglobin in cetylpyridinium bromide film: Redox thermodynamics and electrocatalysis to nitric oxide , 2006 .

[12]  Jianbin Zheng,et al.  Amine-terminated ionic liquid functionalized carbon nanotube-gold nanoparticles for investigating the direct electron transfer of glucose oxidase , 2009 .

[13]  Xiaoli Zhu,et al.  Hemoglobin-based hydrogen peroxide biosensor tuned by the photovoltaic effect of nano titanium dioxide. , 2005, Analytical chemistry.

[14]  Gu Zhou,et al.  Electrochemistry and electrocatalysis with heme proteins in chitosan biopolymer films. , 2002, Analytical biochemistry.

[15]  Hui Xu,et al.  Direct electrochemistry and electrocatalysis of heme proteins immobilized in single-wall carbon nanotubes-surfactant films in room temperature ionic liquids , 2009 .

[16]  Qing Zhang,et al.  Porous nanosheet-based ZnO microspheres for the construction of direct electrochemical biosensors. , 2008, Biosensors & bioelectronics.

[17]  Guohua Zhao,et al.  Carboxyphenyl Covalent Immobilization of Heme Proteins and its Favorable Biocompatible Electrochemical and Electrocatalytic Characteristics , 2008 .

[18]  Peter Wasserscheid,et al.  Ionic Liquids in Synthesis , 2002 .

[19]  Lixian Sun,et al.  Direct electron transfer of cytochrome c and its biosensor based on gold nanoparticles/room temperature ionic liquid/carbon nanotubes composite film , 2008 .

[20]  Y. Zheng,et al.  Direct electrochemistry and electrocatalysis of hemoglobin immobilized in TiO2 nanotube films. , 2008, Talanta.

[21]  James F. Rusling,et al.  Heme Protein−Clay Films: Direct Electrochemistry and Electrochemical Catalysis , 2002 .

[22]  J. Kraut,et al.  The stereochemistry of peroxidase catalysis. , 1980, The Journal of biological chemistry.

[23]  G. S. Wilson,et al.  Rotating ring-disk enzyme electrode for biocatalysis kinetic studies and characterization of the immobilized enzyme layer , 1980 .

[24]  Jianbin Zheng,et al.  Direct Electrochemistry of Hemoglobin and Its Electrocatalysis Based on Hyaluronic Acid and Room Temperature Ionic Liquid , 2008 .

[25]  Zong Dai,et al.  Direct electrochemistry of myoglobin based on ionic liquid-clay composite films. , 2009, Biosensors & bioelectronics.

[26]  P. George,et al.  The ionization of acidic metmyoglobin. , 1952, The Biochemical journal.

[27]  Dongxue Han,et al.  Carbon nanotubes and glucose oxidase bionanocomposite bridged by ionic liquid-like unit: preparation and electrochemical properties. , 2007, Biosensors & bioelectronics.

[28]  W. Chae,et al.  Templated carbon nanofiber with mesoporosity and semiconductivity. , 2006, The journal of physical chemistry. B.

[29]  Gang Wang,et al.  Highly sensitive sensors based on the immobilization of tyrosinase in chitosan. , 2002, Bioelectrochemistry.

[30]  Yuan-Yao Li,et al.  Preparation and Characterization of Porous Carbon Nanofibers from Thermal Decomposition of Poly(ethylene glycol) , 2008 .

[31]  Gongxuan Lu,et al.  Hydrogen peroxide biosensor based on direct electrochemistry of hemoglobin immobilized on carbon paste electrode by a silica sol–gel film , 2004 .

[32]  J. Rusling,et al.  PROTON-COUPLED ELECTRON TRANSFER FROM ELECTRODES TO MYOGLOBIN IN ORDERED BIOMEMBRANE-LIKE FILMS , 1997 .

[33]  Katerina Tsagaraki,et al.  Carbon nanofiber-based glucose biosensor. , 2006, Analytical chemistry.

[34]  E. Bismuto,et al.  Unfolding pathway of myoglobin: molecular properties of intermediate forms. , 1986, Archives of biochemistry and biophysics.

[35]  C. Cramer,et al.  Direct examination of H2O2 activation by a heme peroxidase. , 2008, Journal of the American Chemical Society.

[36]  H. Ju,et al.  Biocompatible conductive architecture of carbon nanofiber-doped chitosan prepared with controllable electrodeposition for cytosensing. , 2007, Analytical chemistry.

[37]  Guodong Liu,et al.  Direct electrochemistry and electrocatalysis of heme proteins on SWCNTs-CTAB modified electrodes. , 2009, Talanta.

[38]  Zhiwei Zhu,et al.  Structural and characteristic analysis of carbon nanotubes-ionic liquid gel biosensor , 2007 .

[39]  S. Dong,et al.  Electrochemical catalysis and thermal stability characterization of laccase-carbon nanotubes-ionic liquid nanocomposite modified graphite electrode. , 2007, Biosensors & bioelectronics.

[40]  M. Feng,et al.  Direct electrochemistry and Raman spectroscopy of sol-gel-encapsulated myoglobin. , 2005, Langmuir : the ACS journal of surfaces and colloids.

[41]  A. Safavi,et al.  Direct electrochemistry of hemoglobin and its electrocatalytic effect based on its direct immobilization on carbon ionic liquid electrode , 2008 .

[42]  Jinghong Li,et al.  A novel room temperature ionic liquid sol–gel matrix for amperometric biosensor application , 2005 .

[43]  G Li,et al.  Electron-transfer reactivity and enzymatic activity of hemoglobin in a SP Sephadex membrane. , 2001, Analytical chemistry.

[44]  P. Dutton,et al.  Oxidation-reduction potentials of cytochromes in mitochondria. , 1970, Biochemistry.

[45]  J. Vanderkooi The protein state of matter. , 1998, Biochimica et biophysica acta.

[46]  Hong Sun Direct electrochemical and electrocatalytic properties of heme protein immobilized on ionic liquid-clay-nanoparticle-composite films , 2006 .

[47]  C. M. Li,et al.  Ionic liquid/mesoporous carbon/protein composite microelectrode and its biosensing application , 2009 .

[48]  Ping Wu,et al.  Preparation and characterization of room temperature ionic liquid/single-walled carbon nanotube nanocomposites and their application to the direct electrochemistry of heme-containing proteins/enzymes , 2007 .

[49]  W. Cho,et al.  Electrochemical Reduction of NO by Myoglobin in Surfactant Film: Characterization and Reactivity of The Nitroxyl (NO-) Adduct , 1998 .

[50]  A. Ranieri,et al.  Control of cytochrome C redox potential: axial ligation and protein environment effects. , 2002, Journal of the American Chemical Society.

[51]  Jinghong Li,et al.  Direct electron transfer of horseradish peroxidase and its biosensor based on chitosan and room temperature ionic liquid , 2006 .

[52]  E. Calvo,et al.  Donnan permselectivity in layer-by-layer self-assembled redox polyelectrolye thin films. , 2002, Journal of the American Chemical Society.

[53]  Hongyuan Chen,et al.  Direct electrochemistry and electrocatalysis of heme proteins immobilized on self-assembled ZrO2 film , 2005 .

[54]  Jing-Juan Xu,et al.  Direct electrochemistry and electrocatalysis of heme proteins immobilized on gold nanoparticles stabilized by chitosan. , 2005, Analytical biochemistry.

[55]  Ying Liu,et al.  Electrochemical and bioelectrochemistry properties of room-temperature ionic liquids and carbon composite materials. , 2004, Analytical chemistry.

[56]  Wei‐De Zhang,et al.  The interface behavior of hemoglobin at carbon nanotube and the detection for H(2)O(2). , 2005, Talanta.

[57]  M. Lundstrom,et al.  Ballistic carbon nanotube field-effect transistors , 2003, Nature.

[58]  D. Poncelet,et al.  Membrane formation by interfacial cross‐linking of chitosan for microencapsulation of Lactococcus lactis , 1993, Biotechnology and bioengineering.

[59]  W. Heineman,et al.  Measurement of enzyme E'values by optically transparent thin layer electrochemical cells. , 1975, Analytical chemistry.

[60]  L. Nagahara,et al.  In situ detection of cytochrome c adsorption with single walled carbon nanotube device , 2003 .

[61]  H. Matsumoto,et al.  Electrochemical properties and actuation mechanisms of actuators using carbon nanotube-ionic liquid gel , 2009 .

[62]  Genxi Li,et al.  Electrochemical investigation of redox thermodynamics of immobilized myoglobin: ionic and ligation effects. , 2005, Langmuir : the ACS journal of surfaces and colloids.

[63]  Wei Sun,et al.  Electrochemistry and electrocatalysis of hemoglobin in Nafion/nano-CaCO3 film on a new ionic liquid BPPF6 modified carbon paste electrode. , 2007, The journal of physical chemistry. B.

[64]  S. Sligar,et al.  The One-electron Autoxidation of Human Cytochrome P450 3A4* , 2007, Journal of Biological Chemistry.