Fibrous Cap Thickness by Optical Coherence Tomography In Vivo.

BACKGROUND Optical coherence tomography (OCT) imaging is considered to be the only imaging modality with sufficient resolution to measure fibrous cap thickness (FCT) in vivo. However, reproducibility of the measurements in vivo has been unsatisfactory. OBJECTIVES The authors aimed to investigate whether satisfactory reproducibility of FCT measurements by OCT in vivo can be achieved between independent observers. METHODS One hundred seventy OCT pullbacks were analyzed by 2 independent observers with intravascular imaging expertise in accordance with current guidelines to assess the interobserver variability of FCT measurement by intraclass correlation coefficient (ICC). The main sources of the variability were analyzed and incorporated in lesion assessment criteria. The same 170 OCT pullbacks were reanalyzed by the same observers using the developed criteria, and the interobserver reproducibility of the measurements was reassessed. On the basis of the developed criteria, a third independent observer interpreted all 170 OCT images. Assessment of the maximal lipid arc was also undertaken similarly before and after the development of interpretation criteria. RESULTS The original ICC of the FC thickness was 0.56 (95% confidence interval [CI]: 0.38 to 0.69). The poor definition of necrotic core facing border of FC and the neointimal presence of macrophages and calcification contributed to the high interobserver variability of FCT measurement. The ICC of FCT measurements by OCT in vivo was 0.88 (95% CI: 0.80 to 0.93) after we developed lesion assessment criteria. The ICC for the maximal lipid arc assessment before and after was 0.76 and 0.82 respectively. The third independent observer was extensively coached and returned the ICC of 0.82 (95% CI: 0.74 to 0.87) with observer 1 and 0.90 (95% CI: 0.86 to 0.94) with observer 2. CONCLUSIONS Careful consideration of OCT features mimicking fibroatheroma lesions and imaging artifacts contributed to significantly higher levels of interobserver agreement. Interobserver variation can be partially resolved by development of standard interpretation algorithms.

[1]  Seiichi Hirota,et al.  Accuracy of OCT, grayscale IVUS, and their combination for the diagnosis of coronary TCFA: an ex vivo validation study. , 2015, JACC. Cardiovascular imaging.

[2]  R. Virmani,et al.  Coronary risk factors and plaque morphology in men with coronary disease who died suddenly. , 1997, The New England journal of medicine.

[3]  Eloisa Arbustini,et al.  Sources of error and interpretation of plaque morphology by optical coherence tomography. , 2006, The American journal of cardiology.

[4]  V. Fuster,et al.  Histopathologic characteristics of atherosclerotic coronary disease and implications of the findings for the invasive and noninvasive detection of vulnerable plaques. , 2013, Journal of the American College of Cardiology.

[5]  E. Halpern,et al.  Multi-laboratory inter-institute reproducibility study of IVOCT and IVUS assessments using published consensus document definitions. , 2016, European heart journal cardiovascular Imaging.

[6]  Gijs van Soest,et al.  Pitfalls in plaque characterization by OCT: image artifacts in native coronary arteries. , 2011, JACC. Cardiovascular imaging.

[7]  F. Mastik,et al.  Combined optical coherence tomography and intravascular ultrasound radio frequency data analysis for plaque characterization. Classification accuracy of human coronary plaques in vitro , 2010, The International Journal of Cardiovascular Imaging.

[8]  Hang Lee,et al.  Reproducibility of in vivo measurements for fibrous cap thickness and lipid arc by OCT. , 2012, JACC. Cardiovascular imaging.

[9]  Eloisa Arbustini,et al.  Expert review document on methodology, terminology, and clinical applications of optical coherence tomography: physical principles, methodology of image acquisition, and clinical application for assessment of coronary arteries and atherosclerosis. , 2010, European heart journal.

[10]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[11]  Y. Neishi,et al.  Measurement of the thickness of the fibrous cap by optical coherence tomography. , 2006, American heart journal.

[12]  J. R. Landis,et al.  The measurement of observer agreement for categorical data. , 1977, Biometrics.

[13]  Akiko Maehara,et al.  Consensus standards for acquisition, measurement, and reporting of intravascular optical coherence tomography studies: a report from the International Working Group for Intravascular Optical Coherence Tomography Standardization and Validation. , 2012, Journal of the American College of Cardiology.

[14]  R. Virmani,et al.  Lessons from sudden coronary death: a comprehensive morphological classification scheme for atherosclerotic lesions. , 2000, Arteriosclerosis, thrombosis, and vascular biology.

[15]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[16]  R. Virmani,et al.  Clinical classification of plaque morphology in coronary disease , 2014, Nature Reviews Cardiology.