Dynamic Error Analysis of Ascension's Flock of Birds TM Electromagnetic Tracking Device Using a Pendulum Model

The use of magnetic tracking technology has become increasingly popular in recent years for human motion studies. However, there have been few independent evaluations of how these systems perform. The purpose of this study was to develop a dynamic pendulum calibration method to test the performance of magnetic tracking sensors. A nonmetallic pendulum was constructed and instrumented with a rotary potentiometer. A cube was attached to the distal end of the pendulum so that sensors could be mounted orthogonally. In this manner, it was possible to obtain simultaneous recordings of azimuth, elevation, and roll depending on the sensor mounting orientation relative to the axis of rotation of the pendulum. Sensor data, using Flock of Birds™ sensors, and potentiometer data were collected simultaneously during dynamic pendulum motion at two transmitter distances and then were compared. The results showed excellent trial-to-trial repeatability of 2% or better for the sensors, and high correlations between the senso...

[1]  G L Smidt,et al.  Effects of local muscle fatigue on three-dimensional scapulohumeral rhythm. , 1995, Clinical biomechanics.

[2]  K. Singer,et al.  Assessment of combined movements of the lumbar spine in asymptomatic and low back pain subjects using a three-dimensional electromagnetic tracking system. , 1999, Manual therapy.

[3]  G R Johnson,et al.  Measurement of three-dimensional shoulder movement by an electromagnetic sensor. , 1990, Clinical biomechanics.

[4]  D A Nawoczenski,et al.  Three-dimensional scapular orientation and muscle activity at selected positions of humeral elevation. , 1996, The Journal of orthopaedic and sports physical therapy.

[5]  H. K. Ramakrishnan,et al.  Repeatability of kinematic, kinetic, and electromyographic data in normal adult gait , 1989, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[6]  F. V. D. van der Helm,et al.  Calibration of the "Flock of Birds" electromagnetic tracking device and its application in shoulder motion studies. , 1999, Journal of biomechanics.

[7]  J A Sidles,et al.  Translation of the humeral head on the glenoid with passive glenohumeral motion. , 1990, The Journal of bone and joint surgery. American volume.

[8]  K N An,et al.  Application of a magnetic tracking device to kinesiologic studies. , 1988, Journal of biomechanics.

[9]  G A Dumas,et al.  Evaluation of a long-range transmitter for use with a magnetic tracking device in motion analysis. , 1998, Journal of biomechanics.

[10]  M J Pearcy,et al.  New method for the non-invasive three-dimensional measurement of human back movement. , 1989, Clinical biomechanics.

[11]  T. Brown,et al.  Assessment of elbow joint kinematics in passive motion by electromagnetic motion tracking , 2000, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[12]  J. Woodburn,et al.  A preliminary study determining the feasibility of electromagnetic tracking for kinematics at the ankle joint complex. , 1999, Rheumatology.

[13]  A R Karduna,et al.  Scapular kinematics: effects of altering the Euler angle sequence of rotations. , 2000, Journal of biomechanics.

[14]  J Riess,et al.  Evaluation of FNS control systems: software development and sensor characterization. , 1997, Biomedical sciences instrumentation.

[15]  C.G.M. Meskers,et al.  3D shoulder position measurements using a six-degree-of-freedom electromagnetic tracking device. , 1998, Clinical biomechanics.

[16]  David A. Winter,et al.  Biomechanics and Motor Control of Human Movement , 1990 .