Validation of vertical ground heat exchanger design methodologies

This work presents a validation of two common methods for designing vertical ground heat exchangers. Both a simulation-based design tool and the ASHRAE handbook design equation are used to find design lengths for four different real systems, using actual experimental data, including building loads as well as physical parameters as inputs. The measured minimum and maximum ground heat exchanger exiting fluid temperatures were used as the design constraint. The simulation-based design tool predicted the borehole length to within 6% in all cases, while the ASHRAE handbook design equation yielded systems with errors from –21% to 167%. Most of this error can be explained by the way loads are represented in the ASHRAE handbook equation, with differences in the borehole thermal resistance also playing a smaller part. The ASHRAE handbook equation relies on a very simple load representation; although this allows it to be used as a simple hand calculation, it also precludes it achieving acceptable accuracy. It does not appear to be possible to revise the ASHRAE handbook equation so as to both significantly improve its accuracy and allow its use in a simple hand calculation.

[1]  Xiaobing Liu,et al.  ENHANCEMENTS OF AN INTEGRATED SIMULATION TOOL FOR GROUND-SOURCE HEAT PUMP SYSTEM DESIGN AND ENERGY ANALYSIS , 2006 .

[2]  Jeffrey D. Spitler,et al.  Analysis of vertical ground loop heat exchangers applied to buildings in the UK , 2007 .

[3]  Marco Fossa,et al.  The temperature penalty approach to the design of borehole heat exchangers for heat pump application , 2011 .

[4]  G. Hellström,et al.  Multipole method to compute the conductive heat flows to and between pipes in a composite cylinder , 1987 .

[5]  Dominique Marchio,et al.  Sizing Calculation Spreadsheet Vertical Geothermal Borefields , 2010 .

[6]  Tomislav Kurevija,et al.  Effect of borehole array geometry and thermal interferences on geothermal heat pump system , 2012 .

[7]  Jeff W. Thornton,et al.  A comparison of vertical ground heat exchanger design software for commercial applications , 2000 .

[8]  G. Hellström,et al.  Multipole method to calculate borehole thermal resistances in a borehole heat exchanger , 2011, HVAC&R Research.

[9]  Jeffrey D. Spitler,et al.  Field Validation of a Short Time Step Model for Vertical Ground-Loop Heat Exchangers , 2001 .

[10]  Jeffrey D. Spitler,et al.  A computationally efficient hybrid time step methodology for simulation of ground heat exchangers , 2011 .

[11]  S S Naicker,et al.  Monitoring and Performance Analysis of Large Non-domestic Ground Source Heat Pump Installation , 2011 .

[12]  Michele De Carli,et al.  Design of borehole heat exchangers for ground-source heat pumps: A literature review, methodology comparison and analysis on the penalty temperature , 2012 .

[13]  James R. Cullin,et al.  Improvements in design procedures for ground source and hybrid ground source heat pump systems , 2008 .

[14]  Simon J. Rees,et al.  Implementation and Validation of Ground-Source Heat Pump System Models in an Integrated Building and System Simulation Environment , 2006 .

[15]  José M. Corberán,et al.  Analysis of the energy performance of a ground source heat pump system after five years of operation , 2011 .

[16]  Per Eskilson Thermal analysis of heat extraction boreholes , 1987 .