A case of deep infection after instrumentation in dorsal spinal surgery: the management with antibiotics and negative wound pressure without removal of fixation

Until today the role of spinal instrumentation in the presence of a wound infection has been widely discussed and recently many authors leave the hardware in place with appropriate antibiotic therapy. This is a case of a 65-year-old woman suffering from degenerative scoliosis and osteoporotic multiple vertebral collapses treated with posterior dorsolumbar stabilisation with screws and rods. Four months later, skin necrosis and infection appeared in the cranial wound with exposure of the rods. A surgical procedure of debridement of the infected tissue and package with a myocutaneous trapezius muscle flap was performed. One week after surgery, negative pressure wound therapy was started on the residual skin defect. The wound healed after 2 months. The aim of this case report is to focus on the utility of this method even in the case of hardware exposure and infection. This may help avoid removing instrumentation and creating instability.

[1]  M. Sergi,et al.  The effectiveness of negative pressure therapy on infected wounds: preliminary results , 2017, International wound journal.

[2]  W. Ding,et al.  Factors predicting surgical site infection after posterior lumbar surgery , 2017, Medicine.

[3]  A. El-Sabbagh Negative pressure wound therapy: An update , 2017, Chinese journal of traumatology = Zhonghua chuang shang za zhi.

[4]  T. Setoguchi,et al.  Risk factors for unavoidable removal of instrumentation after surgical site infection of spine surgery , 2016, Medicine.

[5]  M. Scerrati,et al.  Treatment of unstable thoracolumbar junction fractures: short-segment pedicle fixation with inclusion of the fracture level versus long-segment instrumentation , 2016, Acta Neurochirurgica.

[6]  M. Scerrati,et al.  Posterior Titanium Screw Fixation without Debridement of Infected Tissue for the Treatment of Thoracolumbar Spontaneous Pyogenic Spondylodiscitis , 2016, Asian spine journal.

[7]  S. Sharif,et al.  postoperative Infections of the Spine , 2015 .

[8]  J. Chapman,et al.  Predicting surgical site infection after spine surgery: a validated model using a prospective surgical registry. , 2014, The spine journal : official journal of the North American Spine Society.

[9]  M. Scerrati,et al.  Neurological outcome in a series of 58 patients operated for traumatic thoracolumbar spinal cord injuries , 2014, Surgical neurology international.

[10]  A. Friedman,et al.  2012 Young Investigator Award Winner: The Distribution of Body Mass as a Significant Risk Factor for Lumbar Spinal Fusion Postoperative Infections , 2012, Spine.

[11]  O. Boachie-Adjei,et al.  Postoperative infections of the lumbar spine: presentation and management , 2012, International Orthopaedics.

[12]  A. Gerometta,et al.  Infections in spinal instrumentation , 2012, International Orthopaedics.

[13]  J. Arockiaraj,et al.  The Use of Titanium Mesh Cages in the Reconstruction of Anterior Column Defects in Active Spinal Infections: Can We Rest the Crest? , 2011, Asian spine journal.

[14]  S. Cosgrove,et al.  Intraoperative Fraction of Inspired Oxygen Is a Modifiable Risk Factor for Surgical Site Infection after Spinal Surgery , 2009, Anesthesiology.

[15]  G. Sundararaj,et al.  Treatment of haematogenous pyogenic vertebral osteomyelitis by single-stage anterior debridement, grafting of the defect and posterior instrumentation. , 2007, The Journal of bone and joint surgery. British volume.

[16]  J. Pournaras,et al.  Treatment of Tuberculous Spondylitis with Anterior Stabilization and Titanium Cage , 2006, Clinical orthopaedics and related research.

[17]  S. Wilson,et al.  Serial Abdominal Closure Technique (the “SAC” Procedure): A Novel Method for Delayed Closure of the Abdominal Wall , 2003, The American surgeon.

[18]  G. Howell,et al.  The shoelace technique for wound closure in open fractures: report of early experience. , 1997, Injury.

[19]  Louis C. Argenta,et al.  Vacuum‐Assisted Closure: A New Method for Wound Control and Treatment: Clinical Experience , 1997, Annals of plastic surgery.