Thoracic low-dose CT image processing using an artifact suppressed large-scale nonlocal means

The x-ray exposure to patients has become a major concern in computed tomography (CT) and minimizing the radiation exposure has been one of the major efforts in the CT field. Due to plenty high-attenuation tissues in the human chest, under low-dose scan protocols, thoracic low-dose CT (LDCT) images tend to be severely degraded by excessive mottled noise and non-stationary streak artifacts. Their removal is rather a challenging task because the streak artifacts with directional prominence are often hard to discriminate from the attenuation information of normal tissues. This paper describes a two-step processing scheme called 'artifact suppressed large-scale nonlocal means' for suppressing both noise and artifacts in thoracic LDCT images. Specific scale and direction properties were exploited to discriminate the noise and artifacts from image structures. Parallel implementation has been introduced to speed up the whole processing by more than 100 times. Phantom and patient CT images were both acquired for evaluation purpose. Comparative qualitative and quantitative analyses were both performed that allows conclusion on the efficacy of our method in improving thoracic LDCT data.

[1]  Magnus Båth,et al.  ViewDEX 2.0: a Java-based DICOM-compatible software for observer performance studies , 2009, Medical Imaging.

[2]  Jitendra Malik,et al.  Scale-Space and Edge Detection Using Anisotropic Diffusion , 1990, IEEE Trans. Pattern Anal. Mach. Intell..

[3]  Gabriele Lohmann,et al.  Image restoration and spatial resolution in 7‐tesla magnetic resonance imaging , 2010, Magnetic resonance in medicine.

[4]  Gyula Faigel,et al.  X-Ray Holography , 1999 .

[5]  L. Tanoue Computed Tomography — An Increasing Source of Radiation Exposure , 2009 .

[6]  Jean-Michel Morel,et al.  A non-local algorithm for image denoising , 2005, 2005 IEEE Computer Society Conference on Computer Vision and Pattern Recognition (CVPR'05).

[7]  Noriyuki Tomiyama,et al.  Pulmonary nodules: effect of adaptive statistical iterative reconstruction (ASIR) technique on performance of a computer-aided detection (CAD) system-comparison of performance between different-dose CT scans. , 2012, European journal of radiology.

[8]  Hiroto Hatabu,et al.  Use of 3D adaptive raw-data filter in CT of the lung: effect on radiation dose reduction. , 2008, AJR. American journal of roentgenology.

[9]  Wufan Chen,et al.  Improving low-dose X-ray CT images by Weighted Intensity Averaging over Large-scale Neighborhoods , 2010, 2010 International Conference of Medical Image Analysis and Clinical Application.

[10]  Jacques Rémy,et al.  Multi-detector row CT of hemoptysis. , 2006, Radiographics : a review publication of the Radiological Society of North America, Inc.

[11]  Dag Rune Olsen,et al.  Improved image quality of low‐dose thoracic CT examinations with a new postprocessing software† , 2010, Journal of applied clinical medical physics.

[12]  Rainer Raupach,et al.  Wavelet Based Noise Reduction in CT-Images Using Correlation Analysis , 2008, IEEE Transactions on Medical Imaging.

[13]  Qianjin Feng,et al.  Improving low-dose abdominal CT images by Weighted Intensity Averaging over Large-scale Neighborhoods. , 2011, European journal of radiology.

[14]  G. McVey,et al.  Screening for lung cancer using low dose CT scanning: results of 2 year follow up , 2005, Thorax.

[15]  Wojciech Zbijewski,et al.  Statistical reconstruction for x-ray CT systems with non-continuous detectors. , 2007, Physics in medicine and biology.

[16]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[17]  Thomas L Toth,et al.  Can noise reduction filters improve low-radiation-dose chest CT images? Pilot study. , 2003, Radiology.

[18]  Wufan Chen,et al.  Joint-MAP Tomographic Reconstruction with Patch Similarity Based Mixture Prior Model , 2011, Multiscale Model. Simul..

[19]  C. Kamath,et al.  Undecimated Wavelet Transforms for Image De-noising , 2002 .

[20]  Pierrick Coupé,et al.  An Optimized Blockwise Nonlocal Means Denoising Filter for 3-D Magnetic Resonance Images , 2008, IEEE Transactions on Medical Imaging.

[21]  Michiel Schaap,et al.  Fast Noise Reduction in Computed Tomography for Improved 3-D Visualization , 2008, IEEE Transactions on Medical Imaging.

[22]  J H Siewerdsen,et al.  The reduction of image noise and streak artifact in the thoracic inlet during low dose and ultra-low dose thoracic CT , 2010, Physics in medicine and biology.

[23]  Jing Wang,et al.  Multiscale Penalized Weighted Least-Squares Sinogram Restoration for Low-Dose X-Ray Computed Tomography , 2008, IEEE Transactions on Biomedical Engineering.

[24]  黄亚明 MedScape , 2009 .

[25]  J. Hsieh Adaptive streak artifact reduction in computed tomography resulting from excessive x-ray photon noise. , 1998, Medical physics.

[26]  Max A. Viergever,et al.  Noise Reduction in Computed Tomography Scans Using 3-D Anisotropic Hybrid Diffusion With Continuous Switch , 2009, IEEE Transactions on Medical Imaging.

[27]  Albert Ronald Pencho Hong Cohen,et al.  Nonlinear approximation and the space BV[inline-graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="01i" /] , 1999 .

[28]  G. McVey,et al.  Screening for lung cancer using low dose CT scanning: results of 2 year follow up , 2005, Thorax.

[29]  Aleksandra Pizurica,et al.  A GPU-Accelerated Real-Time NLMeans Algorithm for Denoising Color Video Sequences , 2010, ACIVS.

[30]  Cong Nie,et al.  Bayesian statistical reconstruction for low-dose X-ray computed tomography using an adaptive-weighting nonlocal prior , 2009, Comput. Medical Imaging Graph..

[31]  Cynthia H McCollough,et al.  Monte Carlo simulations to assess the effects of tube current modulation on breast dose for multidetector CT , 2009, Physics in medicine and biology.

[32]  J M Bland,et al.  Statistical methods for assessing agreement between two methods of clinical measurement , 1986 .

[33]  Bram van Ginneken,et al.  Local noise weighted filtering for emphysema scoring of low-dose CT images , 2006, IEEE Transactions on Medical Imaging.

[34]  M. Kalra,et al.  Strategies for CT radiation dose optimization. , 2004, Radiology.

[35]  Guillermo Sapiro,et al.  Fast image and video denoising via nonlocal means of similar neighborhoods , 2005, IEEE Signal Processing Letters.

[36]  Mark J. Shensa,et al.  The discrete wavelet transform: wedding the a trous and Mallat algorithms , 1992, IEEE Trans. Signal Process..