Thoracic low-dose CT image processing using an artifact suppressed large-scale nonlocal means
暂无分享,去创建一个
Christine Toumoulin | Yang Chen | Yinsheng Li | Guanyu Yang | Yining Hu | Zhou Yang | Yongcheng Zhu | Limin luo | Wufan Chen | Wufan Chen | Guanyu Yang | Yang Chen | L. Luo | C. Toumoulin | Yining Hu | Yinsheng Li | Zhou Yang | Yongcheng Zhu
[1] Magnus Båth,et al. ViewDEX 2.0: a Java-based DICOM-compatible software for observer performance studies , 2009, Medical Imaging.
[2] Jitendra Malik,et al. Scale-Space and Edge Detection Using Anisotropic Diffusion , 1990, IEEE Trans. Pattern Anal. Mach. Intell..
[3] Gabriele Lohmann,et al. Image restoration and spatial resolution in 7‐tesla magnetic resonance imaging , 2010, Magnetic resonance in medicine.
[4] Gyula Faigel,et al. X-Ray Holography , 1999 .
[5] L. Tanoue. Computed Tomography — An Increasing Source of Radiation Exposure , 2009 .
[6] Jean-Michel Morel,et al. A non-local algorithm for image denoising , 2005, 2005 IEEE Computer Society Conference on Computer Vision and Pattern Recognition (CVPR'05).
[7] Noriyuki Tomiyama,et al. Pulmonary nodules: effect of adaptive statistical iterative reconstruction (ASIR) technique on performance of a computer-aided detection (CAD) system-comparison of performance between different-dose CT scans. , 2012, European journal of radiology.
[8] Hiroto Hatabu,et al. Use of 3D adaptive raw-data filter in CT of the lung: effect on radiation dose reduction. , 2008, AJR. American journal of roentgenology.
[9] Wufan Chen,et al. Improving low-dose X-ray CT images by Weighted Intensity Averaging over Large-scale Neighborhoods , 2010, 2010 International Conference of Medical Image Analysis and Clinical Application.
[10] Jacques Rémy,et al. Multi-detector row CT of hemoptysis. , 2006, Radiographics : a review publication of the Radiological Society of North America, Inc.
[11] Dag Rune Olsen,et al. Improved image quality of low‐dose thoracic CT examinations with a new postprocessing software† , 2010, Journal of applied clinical medical physics.
[12] Rainer Raupach,et al. Wavelet Based Noise Reduction in CT-Images Using Correlation Analysis , 2008, IEEE Transactions on Medical Imaging.
[13] Qianjin Feng,et al. Improving low-dose abdominal CT images by Weighted Intensity Averaging over Large-scale Neighborhoods. , 2011, European journal of radiology.
[14] G. McVey,et al. Screening for lung cancer using low dose CT scanning: results of 2 year follow up , 2005, Thorax.
[15] Wojciech Zbijewski,et al. Statistical reconstruction for x-ray CT systems with non-continuous detectors. , 2007, Physics in medicine and biology.
[16] D. Altman,et al. STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.
[17] Thomas L Toth,et al. Can noise reduction filters improve low-radiation-dose chest CT images? Pilot study. , 2003, Radiology.
[18] Wufan Chen,et al. Joint-MAP Tomographic Reconstruction with Patch Similarity Based Mixture Prior Model , 2011, Multiscale Model. Simul..
[19] C. Kamath,et al. Undecimated Wavelet Transforms for Image De-noising , 2002 .
[20] Pierrick Coupé,et al. An Optimized Blockwise Nonlocal Means Denoising Filter for 3-D Magnetic Resonance Images , 2008, IEEE Transactions on Medical Imaging.
[21] Michiel Schaap,et al. Fast Noise Reduction in Computed Tomography for Improved 3-D Visualization , 2008, IEEE Transactions on Medical Imaging.
[22] J H Siewerdsen,et al. The reduction of image noise and streak artifact in the thoracic inlet during low dose and ultra-low dose thoracic CT , 2010, Physics in medicine and biology.
[23] Jing Wang,et al. Multiscale Penalized Weighted Least-Squares Sinogram Restoration for Low-Dose X-Ray Computed Tomography , 2008, IEEE Transactions on Biomedical Engineering.
[25] J. Hsieh. Adaptive streak artifact reduction in computed tomography resulting from excessive x-ray photon noise. , 1998, Medical physics.
[26] Max A. Viergever,et al. Noise Reduction in Computed Tomography Scans Using 3-D Anisotropic Hybrid Diffusion With Continuous Switch , 2009, IEEE Transactions on Medical Imaging.
[27] Albert Ronald Pencho Hong Cohen,et al. Nonlinear approximation and the space BV[inline-graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="01i" /] , 1999 .
[28] G. McVey,et al. Screening for lung cancer using low dose CT scanning: results of 2 year follow up , 2005, Thorax.
[29] Aleksandra Pizurica,et al. A GPU-Accelerated Real-Time NLMeans Algorithm for Denoising Color Video Sequences , 2010, ACIVS.
[30] Cong Nie,et al. Bayesian statistical reconstruction for low-dose X-ray computed tomography using an adaptive-weighting nonlocal prior , 2009, Comput. Medical Imaging Graph..
[31] Cynthia H McCollough,et al. Monte Carlo simulations to assess the effects of tube current modulation on breast dose for multidetector CT , 2009, Physics in medicine and biology.
[32] J M Bland,et al. Statistical methods for assessing agreement between two methods of clinical measurement , 1986 .
[33] Bram van Ginneken,et al. Local noise weighted filtering for emphysema scoring of low-dose CT images , 2006, IEEE Transactions on Medical Imaging.
[34] M. Kalra,et al. Strategies for CT radiation dose optimization. , 2004, Radiology.
[35] Guillermo Sapiro,et al. Fast image and video denoising via nonlocal means of similar neighborhoods , 2005, IEEE Signal Processing Letters.
[36] Mark J. Shensa,et al. The discrete wavelet transform: wedding the a trous and Mallat algorithms , 1992, IEEE Trans. Signal Process..