Performance of large-area avalanche photodiode for low-energy X-rays and γ-rays scintillation detection

Abstract We report on the performance of large-area (5×5 mm 2 ) avalanche photodiodes (APD) produced by Hamamatsu Photonics, as a low-energy X-rays and γ-rays scintillation detector. Hamamatsu APD has a reverse structure and works at relatively low bias voltage of 300– 350 V . The leakage current is 1.2 nA at room temperature (25°C) and decreases to 10 pA at −20°C for an avalanche gain of 50. The best FWHM energy resolutions of 9.4±0.3% and 7.4±0.3% were obtained for 59.5 keV γ-rays from 241 Am and 122 keV γ-rays from 57 Co sources, respectively, as measured with a 5×5×5 mm 3 cubic CsI(Tl) crystal. We show that the minimum detectable energy for the scintillation light is remarkably low; 4.6 keV at room temperature (20°C) and 1.1 keV at −20°C. 5.9 keV X-rays from 55 Fe were clearly resolved at −20°C with an FWHM resolution of 32.9±0.3%. These results suggest that Hamamatsu APD can be a promising device for future applications in low-energy scintillation detection.

[1]  D. Renker,et al.  Properties of the most recent avalanche photodiodes for the CMS electromagnetic calorimeter , 2000 .

[2]  S. Kishimoto,et al.  A fast detector using stacked avalanche photodiodes for x-ray diffraction experiments with synchrotron radiation , 1998 .

[3]  M. Moszynski,et al.  Large area avalanche photodiodes in scintillation and X-rays detection $ , 2002 .

[4]  D. Wolski,et al.  Comparative study of avalanche photodiodes with different structures in scintillation detection , 2000, 2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149).

[5]  J. P. Pansart,et al.  AVALANCHE PHOTODIODES FOR PARTICLE DETECTION , 1997 .

[6]  M. Moszynski,et al.  Low energy /spl gamma/-rays scintillation detection with large area avalanche photodiodes , 1998 .

[7]  A. Ochi,et al.  Study of a large area avalanche photodiode as a fast photon and a soft X-ray detector , 1996 .

[8]  Roger Lecomte,et al.  Radiation detection measurements with a new “Buried Junction” silicon avalanche photodiode , 1999 .

[9]  M. Moszynski,et al.  Avalanche photodiodes in scintillation detection , 2003 .

[10]  D. Wolski,et al.  Energy resolution of scintillation detectors readout with large area avalanche photodiodes and photomultipliers , 1998 .

[11]  S. Kishimoto,et al.  A cooled avalanche photodiode detector for X-ray magnetic diffraction experiments , 2001 .

[12]  M. Kapusta,et al.  Performances of large area avalanche photodiodes at liquid nitrogen temperature , 2001 .