Autonomous robot-assisted active catheter insertion using image guidance

In this paper, we investigate autonomous robot- assisted insertion of an active catheter instrumented with shape memory alloy (SMA) actuators using image guidance. An Augmented Hybrid Impedance Control (AHIC) algorithm is implemented on a Mitsubishi robot (PA 10-7C) to insert the active catheter. The robot is constrained to move in Cartesian space along a pre-defined trajectory while controlling the force of insertion. A closed-loop control scheme has been developed to accurately control the bending in the active catheter. The tip of the active catheter is tracked in real-time to provide information on the path of the catheter and for determining the future course of insertion. The catheter is autonomously guided from the point of entry to the site of plaque buildup, thereby shielding the surgeon from the harmful radiation due to the X-rays used for imaging, providing a more ergonomic approach for catheter insertion. Experimental results are given to illustrate the robot-assisted catheter insertion procedure.

[1]  Zhengyou Zhang,et al.  A Flexible New Technique for Camera Calibration , 2000, IEEE Trans. Pattern Anal. Mach. Intell..

[2]  K. Faulkner,et al.  Deterministic effects in interventional radiology. , 2001, Radiation protection dosimetry.

[3]  A. Abreu,et al.  Pulmonary Artery Rupture Induced by a Pulmonary Artery Catheter: A Case Report and Review of the Literature , 2004, Journal of intensive care medicine.

[4]  Rajnikant V. Patel,et al.  H∞Loop Shaping Controller for Shape Memory Alloy Actuators , 2005, Proceedings of the 44th IEEE Conference on Decision and Control.

[5]  Y. Ikari,et al.  The physics of guiding catheters for the left coronary artery in transfemoral and transradial interventions. , 2005, The Journal of invasive cardiology.

[6]  P. Mayo,et al.  ULTRASOUND DEMONSTRATION OF ASYMMETRY BETWEEN THE LEFT AND RIGHT FEMORAL AND RADIAL ARTERIES , 2006 .

[7]  Rajnikant V. Patel,et al.  Robot-assisted catheter insertion using hybrid impedance control , 2006, Proceedings 2006 IEEE International Conference on Robotics and Automation, 2006. ICRA 2006..

[8]  W. Hacke,et al.  30 day results from the SPACE trial of stent-protected angioplasty versus carotid endarterectomy in symptomatic patients: a randomised non-inferiority trial , 2006, The Lancet.

[9]  J. Jayender,et al.  Image processing algorithms for real-time tracking and control of an active catheter , 2007, 2007 European Control Conference (ECC).

[10]  Rajnikant V. Patel,et al.  Modeling and Control of Shape Memory Alloy Actuators , 2008, IEEE Transactions on Control Systems Technology.

[11]  Donald L. Miller Interventional fluoroscopy: reducing radiation risks for patients and staff. , 2009, Journal of vascular and interventional radiology : JVIR.