Characterization of cardiovascular liver motion for the eventual application of elasticity imaging to the liver in vivo.

Elastography, which uses ultrasound to image the tissue strain that results from an applied displacement, can display tumours and heat-ablated tissue with high contrast. However, its application to liver in vivo may be problematic due to the presence of respiratory and cardiovascular sources of displacement. The aim of this study was to measure the cardiovascular-induced component of natural liver motion for the purpose of planning future work that will either use the motion to produce elasticity images or will compensate for it when employing an external source of displacement. A total of 36 sequences of 7 s real-time radio frequency (RF) echo images of the liver were acquired from six healthy volunteers during breath-hold using a stationary 3.5 MHz transducer. For each image sequence, the axial and lateral components of displacement were measured for each pair of consecutive RF images using 2D-echo tracking. The spatio-temporal character of these displacements was then analysed using a novel approach, employing proper orthogonal decomposition, whereby the dominant motion patterns are described by eigenvectors with the highest eigenvalues. The motion patterns of different liver segments were complex, but they were also found to be cyclic, highly repeatable and capable of producing measurable displacements in the liver. These observations provide good evidence to suggest that it may be possible to correct for natural liver motion when using an externally applied displacement for elasticity imaging. It was also found that about 65%-70% of all liver motion could be described using the first eigenvector. Use of only this component of the motion will greatly simplify the design of a mechanical system to be used in an objective study of elasticity imaging of phantoms and excised tissues in the presence of simulated cardiovascular-induced liver motion.

[1]  L A Crum,et al.  Real-time visualization of high-intensity focused ultrasound treatment using ultrasound imaging. , 2001, Ultrasound in medicine & biology.

[2]  W R Lees,et al.  Minimally invasive treatment of malignant hepatic tumors: at the threshold of a major breakthrough. , 2000, Radiographics : a review publication of the Radiological Society of North America, Inc.

[3]  T. Varghese,et al.  A theoretical framework for performance characterization of elastography: the strain filter , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[4]  C. R. Hill,et al.  Ultrasonic study of in vivo kinetic characteristics of human tissues. , 1986, Ultrasound in medicine & biology.

[5]  J Ophir,et al.  The feasibility of elastographic visualization of HIFU-induced thermal lesions in soft tissues. Image-guided high-intensity focused ultrasound. , 1999, Ultrasound in medicine & biology.

[6]  M. Doyley,et al.  A freehand elastographic imaging approach for clinical breast imaging: system development and performance evaluation. , 2001, Ultrasound in medicine & biology.

[7]  G. Haar,et al.  Ultrasound focal beam surgery. , 1995 .

[8]  D. Hill,et al.  Medical image registration , 2001, Physics in medicine and biology.

[9]  P. VanBaren,et al.  Motion compensation algorithm for noninvasive two-dimensional temperature estimation using diagnostic pulse-echo ultrasound , 1998, Photonics West - Biomedical Optics.

[10]  J Ophir,et al.  The effects of digitization on the elastographic signal-to-noise ratio. , 2002, Ultrasound in medicine & biology.

[11]  W.K. Jenkins,et al.  The impact of various imaging parameters on ultrasonic displacement and velocity estimates , 1994, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[12]  T A Krouskop,et al.  Elastographic imaging of thermal lesions in soft tissue: a preliminary study in vitro. , 1998, Ultrasound in medicine & biology.

[13]  W. Walker,et al.  A fundamental limit on delay estimation using partially correlated speckle signals , 1995, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[14]  M. Doyley,et al.  Elastographic imaging of thermally ablated tissue in vitro , 1999, 1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium (Cat. No.99CH37027).

[15]  Jeffrey C Bamber,et al.  Imaging of temperature-induced echo strain: preliminary in vitro study to assess feasibility for guiding focused ultrasound surgery. , 2004, Ultrasound in medicine & biology.

[16]  G E Trahey,et al.  Angle independent ultrasonic blood flow detection by frame-to-frame correlation of B-mode images. , 1988, Ultrasonics.

[17]  Nicholas Ayache,et al.  Tracking brain deformations in time sequences of 3D US images , 2003, Pattern Recognit. Lett..

[18]  J. Ophir,et al.  Elastography: A Quantitative Method for Imaging the Elasticity of Biological Tissues , 1991, Ultrasonic imaging.

[19]  Masahiro Hiraoka,et al.  A technique for noninvasive respiratory gated radiation treatment system based on a real time 3D ultrasound image correlation: a phantom study. , 2004, Medical physics.

[20]  A. Horwich,et al.  Preliminary results of a phase I dose escalation clinical trial using focused ultrasound in the treatment of localised tumours. , 1999, European journal of ultrasound : official journal of the European Federation of Societies for Ultrasound in Medicine and Biology.

[21]  Jonathan Ophir,et al.  Technical NotesThe feasibility of elastographic visualization of HIFU-induced thermal lesions in soft tissues , 1999 .

[22]  T. Varghese,et al.  Elastographic imaging of thermal lesions in the liver in vivo following radiofrequency ablation: preliminary results. , 2002, Ultrasound in medicine & biology.

[23]  P. Holmes,et al.  The Proper Orthogonal Decomposition in the Analysis of Turbulent Flows , 1993 .

[24]  K. L. Moore,et al.  Clinically Oriented Anatomy , 1985 .

[25]  C. R. Hill,et al.  Application of Fourier analysis to clinical study of patterns of tissue movement. , 1988, Ultrasound in medicine & biology.

[26]  Jeffrey C. Bamber,et al.  Speed of Sound , 2005 .

[27]  J C Bamber,et al.  Acoustic properties of lesions generated with an ultrasound therapy system. , 1993, Ultrasound in medicine & biology.

[28]  Benjamin Movsas,et al.  Measurement of intrafractional prostate motion using magnetic resonance imaging. , 2002, International journal of radiation oncology, biology, physics.

[29]  J Ophir,et al.  The nonstationary strain filter in elastography: Part I. Frequency dependent attenuation. , 1997, Ultrasound in medicine & biology.

[30]  L.N. Bohs,et al.  A novel method for angle independent ultrasonic imaging of blood flow and tissue motion , 1991, IEEE Transactions on Biomedical Engineering.

[31]  J Ophir,et al.  The nonstationary strain filter in elastography: Part II. Lateral and elevational decorrelation. , 1997, Ultrasound in medicine & biology.

[32]  T. Krouskop,et al.  Elastographic characterization of HIFU-induced lesions in canine livers. , 1999, Ultrasound in medicine & biology.