Relationship between magnetic field strength and magnetic-resonance-related acoustic noise levels

The need for better signal-to-noise ratios and resolution has pushed magnetic resonance imaging (MRI) towards high-field MR-scanners for which only little data on MR-related acoustic noise production have been published. The purpose of this study was to validate the theoretical relationship of sound pressure level (SPL) and static magnetic field strength. This is relevant for allowing adequate comparisons of acoustic data of MR systems at various magnetic field strengths. Acoustic data were acquired during various pulse sequences at field strengths of 0.5, 1.0, 1.5 and 2.0 Tesla using the same MRI unit by means of a Helicon rampable magnet. Continuous-equivalent, i.e. time-averaged, linear SPLs and 1/3-octave band frequencies were recorded. Ramping from 0.5 to 1.0 Tesla and from 1.0 to 2.0 Tesla resulted in an SPL increase of 5.7 and 5.2 dB(L), respectively, when averaged over the various pulse sequences. Most of the acoustic energy was in the 1-kHz frequency band, irrespective of magnetic field strength. The relation between field strength and SPL was slightly non-linear, i.e. a slightly less increase at higher field strengths, presumably caused by the elastic properties of the gradient coil encasings.

[1]  H. Fujita,et al.  Characteristics of acoustic noise in echo-planar imaging. , 2001, Frontiers of medical and biological engineering : the international journal of the Japan Society of Medical Electronics and Biological Engineering.

[2]  W A Edelstein,et al.  Characterization and prediction of gradient acoustic noise in MR imagers , 1997, Magnetic resonance in medicine.

[3]  M McJury,et al.  Short communication: acoustic noise levels during magnetic resonance imaging scanning at 1.5 T. , 1994, The British journal of radiology.

[4]  M McJury,et al.  Acoustic noise levels during magnetic resonance imaging scanning at 1.5 T , 1994 .

[5]  Ronald A J J Maas,et al.  Interventional MR imaging at 1.5 T: quantification of sound exposure. , 2002, Radiology.

[6]  A R Palmer,et al.  Sound‐Level Measurements and Calculations of Safe Noise Dosage During EPI at 3 T , 2000, Journal of magnetic resonance imaging : JMRI.

[7]  N. Kiang,et al.  Acoustic noise during functional magnetic resonance imaging. , 2000, The Journal of the Acoustical Society of America.

[8]  P Mansfield,et al.  Sound generation in gradient coil structures for MRI , 1998, Magnetic resonance in medicine.

[9]  L. R. Quartararo,et al.  Noise and Vibration Control Engineering: Principles and Applications , 1992 .

[10]  S. R. Lane,et al.  Acoustic analysis of gradient-coil noise in MR imaging. , 1989, Radiology.

[11]  E Borg,et al.  MRI acoustic noise: Sound pressure and frequency analysis , 1997, Journal of magnetic resonance imaging : JMRI.

[12]  F G Shellock,et al.  Measurement of acoustic noise during MR imaging: evaluation of six "worst-case" pulse sequences. , 1994, Radiology.

[13]  R. Bowtell,et al.  The effect of scanner sound in visual, motor, and auditory functional MRI , 1999, Magnetic resonance in medicine.

[14]  R E Brummett,et al.  Potential hearing loss resulting from MR imaging. , 1988, Radiology.

[15]  D Atkinson,et al.  Determination of gradient magnetic field‐induced acoustic noise associated with the use of echo planar and three‐dimensional, fast spin echo techniques , 1998, Journal of magnetic resonance imaging : JMRI.

[16]  R I Kitney,et al.  Investigation of acoustic noise on 15 MRI scanners from 0.2 T to 3 T , 2001, Journal of magnetic resonance imaging : JMRI.

[17]  Z H Cho,et al.  Analysis of acoustic noise in MRI. , 1997, Magnetic resonance imaging.

[18]  Hiroshi Fujita,et al.  Acoustic noise analysis in echo planar imaging: multicenter trial and comparison with other pulse sequences , 1999, IEEE Transactions on Medical Imaging.