Optical slicing of human retinal tissue in vivo with the adaptive optics scanning laser ophthalmoscope.

We present imaging results in human retinal tissue in vivo that allowed us to determine the axial resolution of the adaptive optics scanning laser ophthalmoscope (AOSLO). The instrument is briefly described, and the imaging results from human subjects are compared with (a) the estimated axial resolution values for a diffraction-limited, double-pass instrument and (b) the measured one for a calibrated diffuse retinal model. The comparison showed that the measured axial resolution, as obtained from optical sectioning of human retinas in vivo, can be as low as 71 microm for a 50 microm confocal pinhole after focusing a 3.5 mm beam with a 100 mm focal-length lens. The axial resolution values typically fall between the predictions from numerical models for diffuse and specular reflectors. This suggests that the reflection from the retinal blood vessel combines diffuse and specular components. This conclusion is supported by the almost universal interpretation that the image of a cylindrical blood vessel exhibits a bright reflection along its apex that is considered specular. The enhanced axial resolution achieved through use of adaptive optics leads to an improvement in the volume resolution of almost 2 orders of magnitude when compared with a conventional scanning laser ophthalmoscope and almost a factor of 3 better than commercially available optical coherence tomographic instruments.

[1]  M Intaglietta,et al.  Confocal laser tomographic analysis of the retina in eyes with macular hole formation and other focal macular diseases. , 1989, American journal of ophthalmology.

[2]  Tony Wilson,et al.  The effect of aberrations on the axial response of confocal imaging systems , 1989 .

[3]  Robert H. Webb,et al.  Scanning Laser Ophthalmoscope , 1981, IEEE Transactions on Biomedical Engineering.

[4]  F W Fitzke,et al.  Imaging the optic nerve and ganglion cell layer , 2000, Eye.

[5]  Junzhong Liang,et al.  Aberrations and retinal image quality of the normal human eye. , 1997, Journal of the Optical Society of America. A, Optics, image science, and vision.

[6]  A. Bradley,et al.  Use of Retroillumination to Visualize Optical Aberrations Caused by Tear Film Break-Up , 2003, Optometry and vision science : official publication of the American Academy of Optometry.

[7]  U. Schmidt-Erfurth,et al.  Confocal laser scanning fluorescence topography: a new method for three-dimensional functional imaging of vascular structures , 2000, Graefe's Archive for Clinical and Experimental Ophthalmology.

[8]  T. Wilson,et al.  The Role of the Pinhole in Confocal Imaging Systems , 1990 .

[9]  B. Masters,et al.  Three-dimensional visualization of confocal sections of in vivo human fundus and optic nerve. , 1993, Current eye research.

[10]  S J Goldowsky,et al.  Scanning laser ophthalmoscopy. , 1988, Rhode Island medical journal.

[11]  Joseph L. Demer,et al.  Positron emission tomographic studies of cortical function in human amblyopia , 1993, Neuroscience & Biobehavioral Reviews.

[12]  A. Roorda,et al.  Theoretical modeling and evaluation of the axial resolution of the adaptive optics scanning laser ophthalmoscope. , 2004, Journal of biomedical optics.

[13]  William R. Freeman,et al.  Laser-tissue interaction and artifacts in confocal scanning laser ophthalmoscopy and tomography , 1994, Neuroscience & Biobehavioral Reviews.

[14]  Carol J. Cogswell,et al.  The Specimen Illumination Path and Its Effect on Image Quality , 1995 .

[15]  C. Sheppard,et al.  Theory and practice of scanning optical microscopy , 1984 .

[16]  M. Boulton,et al.  Three dimensional analysis of the retinal vasculature using immunofluorescent staining and confocal laser scanning microscopy. , 1996, The British journal of ophthalmology.

[17]  M A Mainster,et al.  Scanning Laser Ophthalmoscopy: Clinical Applications , 1982 .

[18]  R. Webb,et al.  Confocal scanning laser ophthalmoscope. , 1987, Applied optics.

[19]  S. Rosolen,et al.  Ocular fundus images with confocal scanning laser ophthalmoscopy in the dog, monkey and minipig. , 2001, Veterinary ophthalmology.

[20]  G. Kino,et al.  CHAPTER 3 – Depth and Transverse Resolution , 1996 .

[21]  S. Asrani,et al.  Serial optical sectioning of macular holes at different stages of development. , 1998, Ophthalmology.

[22]  W N Wykes,et al.  Detection of diabetic retinopathy by scanning laser ophthalmoscopy , 1994, Eye.

[23]  H. E. Keller,et al.  Objective Lenses for Confocal Microscopy , 2006 .

[24]  T. Hebert,et al.  Adaptive optics scanning laser ophthalmoscopy. , 2002, Optics express.

[25]  D R Williams,et al.  Supernormal vision and high-resolution retinal imaging through adaptive optics. , 1997, Journal of the Optical Society of America. A, Optics, image science, and vision.

[26]  R. Weinreb,et al.  Active optical depth resolution improvement of the laser tomographic scanner. , 1989, Applied optics.

[27]  Colin J. R. Sheppard,et al.  Scanning optical microscopy , 2020, Advances in Imaging and Electron Physics.

[28]  J. Pawley,et al.  Handbook of Biological Confocal Microscopy , 1990, Springer US.

[29]  I Iglesias,et al.  Double-pass measurements of the retinal-image quality with unequal entrance and exit pupil sizes and the reversibility of the eye's optical system. , 1995, Journal of the Optical Society of America. A, Optics, image science, and vision.

[30]  A Bradley,et al.  Optical and visual impact of tear break-up in human eyes. , 2000, Investigative ophthalmology & visual science.

[31]  D. Van Norren,et al.  Imaging retinal densitometry with a confocal scanning laser ophthalmoscope , 1989, Vision Research.