Ambulatory blood pressure monitoring: which arm?

To determine the effects of routinely selecting the non-dominant arm for ambulatory blood pressure monitoring (ABPM) on estimates of patients’ blood pressure (BP) and to evaluate the practise of using manual BP from one arm and ambulatory BP from the other on the estimation of white coat effect (WCE), an observational study was conducted in 10 volunteers, exhibiting an interarm resting clinic systolic BP (SBP) difference ⩾10 mm Hg. The main outcome measures were: (i) average ambulatory SBP measured on right and left arm simultaneously during 24 h, and (ii) estimate of WCE derived, by current practise, as the difference between the referral clinic BP (the higher of the manual readings from both arms) and ambulatory non-dominant arm BP, contrasted with the WCE calculated as the difference between clinic and ambulatory readings from the same arm (the arm with the higher manual readings). The supine referral clinic SBP was 16 ± 6 mm Hg higher in the right compared with the left arm. Average 24 h ambulatory SBP was 6 ± 7 mm Hg higher in the right arm (range +17 to −3 mm Hg), P = 0.025. Diastolic BP measurements mirrored the systolic findings. One-third of the WCE, estimated by current practise, could be attributed to inconsistency in the choice of arm for BP measurement. Thus, inconsistency in the selection of arms for BP measurement, by different techniques, may confound estimation of patients’ cardiovascular morbidity risk.

[1]  H. M. Korns,et al.  INEQUALITY OF BLOOD PRESSURE IN THE BRACHIAL ARTERIES, WITH ESPECIAL REFERENCE TO DISEASE OF THE ARCH OF THE AORTA. , 1933, The Journal of clinical investigation.

[2]  N. Kaplan Hypertension: prevalence, risks, and effect of therapy. , 1983, Annals of internal medicine.

[3]  D D Gretler,et al.  Diurnal blood pressure variability and physical activity measured electronically and by diary. , 1993, American journal of hypertension.

[4]  E. O'Brien,et al.  ABC of blood pressure measurement: technique. , 1979, British medical journal.

[5]  W. White,et al.  Multicenter assessment of the QuietTrak ambulatory blood pressure recorder according to the 1992 AAMI guidelines. , 1994, American journal of hypertension.

[6]  B. Martina,et al.  White Coat Hypertension , 2002 .

[7]  M. Murphy,et al.  Factors confounding assessment of ambulatory blood pressure monitors, studied during formal evaluation of the Tycos Quiet-Trak. , 1997, American journal of hypertension.

[8]  M. O'Rourke,et al.  Arterial stiffness, systolic blood pressure, and logical treatment of arterial hypertension. , 1990, Hypertension.

[9]  A. Rodgers,et al.  Blood pressure, antihypertensive treatment and stroke risk. , 1994, Journal of hypertension. Supplement : official journal of the International Society of Hypertension.

[10]  A. C. Burton,et al.  Recommendations for Human Blood Pressure Determination By Sphygmomanometers , 1981, Circulation.

[11]  M. Rueger Blood pressure variations in the two arms. , 1951, Annals of internal medicine.

[12]  P. Gosse,et al.  Clinical significance of white‐coat hypertension , 1994, Journal of hypertension. Supplement : official journal of the International Society of Hypertension.