Astigmatism management in cataract surgery with the AcrySof toric intraocular lens

PURPOSE: To present clinical data from a single‐center prospective clinical trial of the AcrySof toric intraocular lens (IOL). SETTING: Academic Hospital Maastricht, Maastricht, The Netherlands. METHODS: Fifty‐three eyes (43 patients) had implantation of an AcrySof toric IOL. Three toric models were evaluated in cylinder powers of 1.50 diopters (D) (SN60T3; T3 group, n = 16), 2.25 D (SN60T4; T4 group, n = 14), and 3.00 D (SN60T5; T5 group, n = 23) at the IOL plane. The T5 group was subdivided into eyes that could be fully corrected (T5a, n = 13) and eyes that could be partially corrected (T5b, n = 10). RESULTS: Four months postoperatively, the mean uncorrected visual acuity (UCVA) was 0.77 ± 0.23 in the T3 group, 0.93 ± 0.23 in the T4 group, 0.82 ± 0.15 in the T5a group, and 0.47 ± 0.13 in the T5b group. More than 90% of the combined eyes in the T3, T4, and T5a groups achieved a UCVA of 20/40 or better, and almost 80% achieved a UCVA of 20/25 or better. Residual refractive astigmatism of less than 0.75 D was achieved in 74% of eyes and of less than 1.00 D in 91%. The mean IOL misalignment was 2.5 ± 2.1 degrees in the T3 group, 3.5 ± 2.3 degrees in the T4 group, and 4.1 ± 3.5 degrees in the T5 group. CONCLUSION: Implantation of the AcrySof toric IOL proved to be an effective, safe, and predictable method of managing corneal astigmatism in cataract patients.

[1]  Jeffrey D Horn,et al.  Status of toric intraocular lenses , 2007, Current opinion in ophthalmology.

[2]  Joseph Miller Refractions and reflections. , 2004, Survey of ophthalmology.

[3]  D. Koch,et al.  Computerized videokeratography and keratometry in determining intraocular lens calculations , 1996, Journal of cataract and refractive surgery.

[4]  A. Bron,et al.  Postoperative intraocular lens rotation: a randomized comparison of plate and loop haptic implants. , 1999, Ophthalmology.

[5]  A. Michels,et al.  Torische Intraokularlinsen Klinische Ergebnisse und Rotationsstabilität , 2001, Der Ophthalmologe.

[6]  A. Pfützner,et al.  Rotational stability of a single‐piece hydrophobic acrylic intraocular lens: New method for high‐precision rotation control , 2007, Journal of cataract and refractive surgery.

[7]  N. Mamalis,et al.  New technology IOL optics. , 2006, Ophthalmology clinics of North America.

[8]  A. Olmes,et al.  [Toric intraocular lenses. Clinical results and rotational stability]. , 2001, Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft.

[9]  G. Hanselmayer,et al.  Astigmatism correction with a foldable toric intraocular lens in cataract patients. , 2000, Journal of cataract and refractive surgery.

[10]  K. Hoffer Biometry of 7,500 cataractous eyes. , 1980, American journal of ophthalmology.

[11]  P. Bloom,et al.  Evaluation of a toric intraocular lens with a Z‐haptic , 2006, Journal of cataract and refractive surgery.