Continuous-flow fluoro-immunosensor for paclitaxel measurement.

A fluorescence-based continuous-flow immunosensor for sensitive, precise, accurate and fast determination of paclitaxel was developed. The sensor utilizes anti-paclitaxel antibody immobilized through its Fc region and crosslinked by dimethylpimelimidate to protein A attached covalently onto the silanized inner walls of a glass capillary column followed by saturation of the paclitaxel-binding sites with rhodamine-labeled paclitaxel. The assay is based on the displacement and detection downstream of the rhodamine-labeled paclitaxel, by a flow-through spectrofluorometer, as a result of the competition with paclitaxel introduced as a pulse into the stream of carrier buffer flowing through the system. The peak height of the fluorescence intensity profile of the displaced rhodamine-labeled paclitaxel was directly proportional to the concentration of paclitaxel applied and was a function of the carrier buffer flow rate. The sensitivity of the immunosensor response ranged from 0.31 relative fluorescence units (RFU)/ng/ml at a flow rate 0.1 ml/min to 0.52 RFU/ng/ml at 1 ml/min, while the lower detection limit ranged from 1 ng/ml at 0.1 ml/min to 4 ng/ml at 1 ml/min. The immunosensor response was very reproducible (RSD=4.8%; n=10) and linear up to 100 ng/ml. The assay time ranged from 2 min at 1 ml/min to 8 min at 0.1 ml/min. A technique developed to resaturate the antigen binding sites of the immobilized antibody with rhodamine-labeled paclitaxel was successful in regenerating the capillary column without affecting its performance, thus enhancing the economic viability of the immunosensor. The immunosensor was successfully applied for the determination of paclitaxel in human plasma.

[1]  U. Narang,et al.  Multianalyte detection using a capillary-based flow immunosensor. , 1998, Analytical biochemistry.

[2]  A. Sharma,et al.  Reversed-phase high-performance liquid chromatographic determination of taxol in mouse plasma. , 1994, Journal of chromatography. B, Biomedical applications.

[3]  S. Suye,et al.  A receptor protein-based bioassay for quantitative determination of paclitaxel. , 1997, Analytical chemistry.

[4]  R. H. Kline,et al.  Fiber optic immunosensor for polychlorinated biphenyls , 1995 .

[5]  R. Cooks,et al.  Rapid screening for taxanes by tandem mass spectrometry. , 1992, Analytical Chemistry.

[6]  J. Beijnen,et al.  High-performance liquid chromatographic procedure for the quantitative determination of paclitaxel (Taxol) in human plasma. , 1993, Journal of chromatography.

[7]  A. Mulchandani,et al.  Development of a fluorescence immunoassay for measurement of paclitaxel in human plasma. , 2000, Analytical biochemistry.

[8]  M. Shuler,et al.  Metabolic Inhibitors, Elicitors, and Precursors as Tools for Probing Yield Limitation in Taxane Production by Taxuschinensis Cell Cultures , 1996, Biotechnology progress.

[9]  A. McPhail,et al.  Plant antitumor agents. VI. The isolation and structure of taxol, a novel antileukemic and antitumor agent from Taxus brevifolia. , 1971, Journal of the American Chemical Society.

[10]  R. Donehower,et al.  Taxol: a novel investigational antimicrotubule agent. , 1990, Journal of the National Cancer Institute.

[11]  E. Hamel,et al.  Tubulin-dependent biochemical assay for the antineoplastic agent taxol and application to measurement of the drug in serum. , 1982, Cancer treatment reports.

[12]  G. Hempel,et al.  Determination of paclitaxel in biological fluids by micellar electrokinetic chromatography. , 1996, Journal of chromatography. A.

[13]  G. S. Wilson,et al.  High sensitivity ELISA determination of taxol in various human biological fluids. , 1999, Journal of pharmaceutical and biomedical analysis.

[14]  Stu Borman Two research groups achieve total synthesis of taxol , 1994 .

[15]  F. Ligler,et al.  Use of the USDT flow immunosensor for quantitation of benzoylecgonine in urine. , 1996, Biosensors & bioelectronics.

[16]  H. Issaq,et al.  High-performance liquid chromatography and micellar electrokinetic chromatography of taxol and related taxanes from bark and needle extracts of Taxus species. , 1994, Journal of chromatography. B, Biomedical applications.

[17]  D. Faulds,et al.  Paclitaxel. A review of its pharmacodynamic and pharmacokinetic properties and therapeutic potential in the treatment of cancer. , 1994, Drugs.

[18]  Yuan Jiang,et al.  A convenient tubulin-based quantitative assay for paclitaxel (Taxol) derivatives more effective in inducing assembly than the parent compound , 1996, Cancer Chemotherapy and Pharmacology.

[19]  E. Turiel,et al.  Flow-through fluorescence immunosensor for atrazine determination. , 1998, Talanta.

[20]  H. Issaq,et al.  Multimodal thin layer chromatographic separation of taxol and related compounds from Taxus brevifolia , 1989 .

[21]  A. Stierle,et al.  Taxol and taxane production by Taxomyces andreanae, an endophytic fungus of Pacific yew. , 1993, Science.

[22]  P. Schiff,et al.  Characterization of polyclonal and monoclonal anti-taxol antibodies and measurement of taxol in serum. , 1993, Cancer research.

[23]  N Kumar,et al.  Taxol-induced polymerization of purified tubulin. Mechanism of action. , 1981, The Journal of biological chemistry.

[24]  G. Theodoridis,et al.  Taxol Analysis by High Performance Liquid Chromatography: A Review , 1996 .

[25]  A. Durand,et al.  Assay of paclitaxel (Taxol) in plasma and urine by high-performance liquid chromatography. , 1998, Journal of chromatography. B, Biomedical sciences and applications.

[26]  P. Grothaus,et al.  An enzyme immunoassay for the determination of taxol and taxanes in Taxus sp. tissues and human plasma. , 1993, Journal of immunological methods.

[27]  K. Nicolaou,et al.  Total synthesis of taxol , 1994, Nature.