Cascaded Multilevel Active Rectifier Fed Three-Phase Smart Pump Load on Single-Phase Rural Feeder

Irrigation pumping system that marks a sizeable load on the grid is generally blind on assessment of peak demand hours, while in operation. Such operation if smartly controlled may avoid shedding of some connected loads to match power demand. Moreover, due to the accessibility of only single-phase supply, the rural pump three-phase loads are supplied through either by splitting ac single phase into three phases or by single phase ac–dc three-phase ac conversion. Such configuration suffers from power quality problems, higher capacitor voltages, and common mode voltage problems, etc. A seven-level cascaded multilevel active rectifier (CMAR) is proposed here to provide power through three different dc links to reduce the voltage rating of capacitors, feed vector-controlled open end winding induction motor pump in addition to variable illumination LED lighting. The control employed for CMAR enhances the grid support operation by flexibly controlling power on the dc links. The control is invoked by adjusting the speed of the pump by sensing the grid frequency using droop characteristics thereby acting as smart pump load. The effectiveness of the proposed configuration and control is investigated both through simulation and experimentation on same scale hardware prototype.

[1]  Yasser Abdel-Rady I. Mohamed,et al.  Stabilization of Medium-Frequency Modes in Isolated Microgrids Supplying Direct Online Induction Motor Loads , 2014, IEEE Transactions on Smart Grid.

[2]  Jia Liu,et al.  Comparison of Dynamic Characteristics Between Virtual Synchronous Generator and Droop Control in Inverter-Based Distributed Generators , 2016, IEEE Transactions on Power Electronics.

[3]  Dong-Choon Lee,et al.  Control of Single-Phase-to-Three-Phase AC/DC/AC PWM Converters for Induction Motor Drives , 2007, IEEE Transactions on Industrial Electronics.

[4]  Luis Marroyo,et al.  Individual Voltage Balancing Strategy for PWM Cascaded H-Bridge Converter-Based STATCOM , 2008, IEEE Transactions on Industrial Electronics.

[5]  Zhiqiao Wu,et al.  Control of an induction motor drive fed with a single-phase fed sparse PWM rectifier/inverter , 2005 .

[6]  Qing-Shan Jia,et al.  Simulation-Based Policy Improvement for Energy Management in Commercial Office Buildings , 2012, IEEE Transactions on Smart Grid.

[7]  Chaitanya Guddanti,et al.  An Improved Single-Phase Active-Front-End Rectifier System for Use With Three-Phase Variable-Frequency Drives , 2015, IEEE Transactions on Industry Applications.

[8]  Haider A. F. Almurib,et al.  SHE–PWM Cascaded Multilevel Inverter With Adjustable DC Voltage Levels Control for STATCOM Applications , 2014, IEEE Transactions on Power Electronics.

[9]  Akshay Kumar Rathore,et al.  New Optimal Pulsewidth Modulation for Single DC-Link Dual-Inverter Fed Open-End Stator Winding Induction Motor Drive , 2015, IEEE Transactions on Power Electronics.

[10]  R. Naderi,et al.  Phase-Shifted Carrier PWM Technique for General Cascaded Inverters , 2008, IEEE Transactions on Power Electronics.

[11]  Young-Jin Kim,et al.  Modeling and Analysis of a Variable Speed Heat Pump for Frequency Regulation Through Direct Load Control , 2015, IEEE Transactions on Power Systems.

[12]  Jung-Ik Ha,et al.  Direct Power Control of a Three-Phase Inverter for Grid Input Current Shaping of a Single-Phase Diode Rectifier With a Small DC-Link Capacitor , 2015, IEEE Transactions on Power Electronics.

[13]  Alex Q. Huang,et al.  Small-Signal Model-Based Control Strategy for Balancing Individual DC Capacitor Voltages in Cascade Multilevel Inverter-Based STATCOM , 2009, IEEE Transactions on Industrial Electronics.

[14]  B. Singh,et al.  Selective Compensation of Power-Quality Problems Through Active Power Filter by Current Decomposition , 2008, IEEE Transactions on Power Delivery.

[15]  Leopoldo García Franquelo,et al.  Selective Harmonic Mitigation Technique for High-Power Converters , 2010, IEEE Transactions on Industrial Electronics.

[16]  Nady Rocha,et al.  Single-Phase to Three-Phase Drive System Using Two Parallel Single-Phase Rectifiers , 2010, IEEE Transactions on Power Electronics.

[17]  P. Enjeti,et al.  A new single phase to three phase converter with active input current shaping for low cost AC motor drives , 1990, Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting.

[18]  I. Cadirci,et al.  Effects of instantaneous power-supply failure on the operation of slip-energy recovery drives , 2005, IEEE Transactions on Energy Conversion.

[19]  Hirofumi Akagi,et al.  A Passive EMI Filter for Eliminating Both Bearing Current and Ground Leakage Current from an Inverter-Driven Motor , 2005 .

[20]  Hyosung Kim,et al.  Filter design for grid connected PV inverters , 2008, 2008 IEEE International Conference on Sustainable Energy Technologies.

[21]  Sachin Jain,et al.  An Integrated Control Algorithm for a Single-Stage PV Pumping System Using an Open-End Winding Induction Motor , 2016, IEEE Transactions on Industrial Electronics.

[22]  Jacob Østergaard,et al.  Smart Demand for Frequency Regulation: Experimental Results , 2013, IEEE Transactions on Smart Grid.

[23]  K. Gopakumar,et al.  A multilevel inverter system for an induction motor with open-end windings , 2005, IEEE Transactions on Industrial Electronics.

[24]  Dhruv Kumar,et al.  SRF based modeling and control of cascaded multilevel active rectifier with uniform DC-buses , 2014, 2014 Recent Advances in Engineering and Computational Sciences (RAECS).

[25]  Jaime Rodriguez Arribas,et al.  Optimal vector control of pumping and ventilation induction motor drives , 2002, IEEE Trans. Ind. Electron..

[26]  Hui Zhong,et al.  Dynamic performance analysis of novel series-connected capacitor-run three-phase induction motor fed by single-phase supply , 2014, 2014 IEEE Transportation Electrification Conference and Expo (ITEC).

[27]  Carlo Cecati,et al.  Design of H-bridge multilevel active rectifier for traction systems , 2002 .