Development of an electrostatic levitator for neutron diffraction structure analysis

An electrostatic levitation (ESL) furnace was designed for the neutron diffraction study of condensed matter. This apparatus is composed of an electrostatic levitator, a neutron inlet path with Cd slit, a 160 degree window for the scattered neutrons, a CO2 laser for sample heating, and an optical pyrometer for temperature measurements. A preliminary neutron diffraction experiment with this ESL was performed for polycrystalline alumina. The sample position could be controlled with an accuracy of ±0.1 mm. The observed Bragg peaks were in complete agreement with those derived from the lattice data of alumina obtained from the literature value. This indicates that this facility is attractive for the structural study of condensed matter without containers.

[1]  S. Yoda,et al.  Electrostatic levitation furnace for structural studies of high temperature liquid metals by neutron scattering experiments , 2002 .

[2]  V. Simonet,et al.  Icosahedral short-range order in deeply undercooled metallic melts. , 2002, Physical review letters.

[3]  S. Yoda,et al.  Non-Contact Measurements of Surface Tension and Viscosity of Niobium, Zirconium, and Titanium Using an Electrostatic Levitation Furnace , 2002 .

[4]  S. Yoda,et al.  Non-contact measurements of thermophysical properties of niobium at high temperature , 2001 .

[5]  S. Yoda,et al.  Hybrid electrostatic–aerodynamic levitation furnace for the high-temperature processing of oxide materials on the ground , 2001 .

[6]  S. Schneider,et al.  X-ray diffraction study of undercooled molten silicon , 2001 .

[7]  M. Hanfland,et al.  Electromagnetic levitation apparatus for investigations of the phase selection in undercooled melts by energy-dispersive x-ray diffraction , 2000 .

[8]  A. Soper,et al.  Aerodynamic laser-heated contactless furnace for neutron scattering experiments at elevated temperatures , 2000 .

[9]  I. Egry,et al.  EXAFS studies on undercooled liquid Co80Pd20 alloy , 1999 .

[10]  P. Echegut,et al.  Development of a levitation cell for synchrotron radiation experiments at very high temperature , 1997 .

[11]  I. Egry,et al.  Extended x‐ray‐absorption fine structure studies of levitated undercooled metallic melts , 1996 .

[12]  C. P. Lee,et al.  Oscillations of liquid drops: results from USML-1 experiments in Space , 1996, Journal of Fluid Mechanics.

[13]  Won-Kyu Rhim,et al.  An electrostatic levitator for high-temperature containerless materials processing in 1-g , 1993 .

[14]  T. C. Huang,et al.  Derivation of d-Values from Digitized X-ray and Synchrotron Diffraction Data , 1989 .

[15]  C. G. Windsor,et al.  Pulsed Neutron Scattering , 1981 .