A developed asymmetric PVDF hollow fiber membrane structure for CO2 absorption

Abstract Carbon dioxide (CO 2 ), the main greenhouse gas, has been associated with global climate change. Therefore, it is important to develop technologies to mitigate this issue. In present study, porous hydrophobic polyvinylidene fluoride (PVDF) hollow fiber membranes with developed structure for CO 2 absorption were prepared via a wet spinning process. The prepared membranes were characterized in terms of morphology examination, gas permeability, critical water entry pressure (CEP w ) and mass transfer resistance. From the morphology examination, the membrane showed an almost sponge-like structure with inner skinless layer and ultra-thin outer skin layer. Results of gas permeation test indicated that the membrane possess very small mean pore size (3.96 nm) with high surface porosity. The CO 2 absorption experiment demonstrated a significant improvement in the CO 2 flux of the prepared PVDF membrane compared to the commercial porous polytetrafluoroethylene (PTFE) hollow fiber membrane. At the absorbent flow rate of 200 ml/min, CO 2 flux of the PVDF membrane (4.10 × 10 −4  mol/m 2  s) was approximately 68% higher than the CO 2 flux of the PTFE membrane. In addition, the results indicated that an approximate 25% CO 2 flux reduction was gradually occurred at initial 26 h, then the CO 2 flux maintained constant over 140 h of the operation.

[1]  M. S. Abdullah,et al.  Effect of dope extrusion rate on morphology and performance of hollow fibers membrane for ultrafiltration , 2006 .

[2]  Suhas P. Deshmukh,et al.  Effect of ethanol composition in water coagulation bath on morphology of PVDF hollow fibre membranes , 1998 .

[3]  A. Ismail,et al.  Polysulfone gas separation hollow fiber membranes with enhanced selectivity , 1998 .

[4]  A. E. Jansen,et al.  Membrane contactor applications , 2008 .

[5]  Keat-Teong Lee,et al.  CO2 removal using membrane gas absorption , 2010 .

[6]  Rong Wang,et al.  Mass transfer study and modeling of gas-liquid membrane contacting process by multistage cascade model for CO2 absorption , 2008 .

[7]  Paitoon Tontiwachwuthikul,et al.  Using polypropylene and polytetrafluoroethylene membranes in a membrane contactor for CO2 absorption , 2006 .

[8]  J. M. Henis,et al.  Composite Hollow Fiber Membranes for Gas Separation: The Resistance Model Approach , 1981 .

[9]  Kang Li,et al.  Tailor‐made asymmetric PVDF hollow fibers for soluble gas removal , 1999 .

[10]  Rong Wang,et al.  Effect of membrane structure on mass-transfer in the membrane gas–liquid contacting process using microporous PVDF hollow fibers , 2006 .

[11]  A. Ismail,et al.  Effect of additives on the structure and performance of polysulfone hollow fiber membranes for CO2 absorption , 2010 .

[12]  A. Ismail,et al.  Enhanced gas permeation performance of polyethersulfone mixed matrix hollow fiber membranes using novel Dynasylan Ameo silane agent , 2008 .

[13]  Marcel Mulder,et al.  Basic Principles of Membrane Technology , 1991 .

[14]  Timothy E. Fout,et al.  Advances in CO2 capture technology—The U.S. Department of Energy's Carbon Sequestration Program ☆ , 2008 .

[15]  E. Drioli,et al.  Effect of additives in the casting solution on the formation of PVDF membranes , 2006 .

[16]  Ahmad Fauzi Ismail,et al.  Effect of operating conditions on the physical and chemical CO2 absorption through the PVDF hollow fiber membrane contactor , 2010 .

[17]  George P. Sakellaropoulos,et al.  A study of mass transfer resistance in membrane gas–liquid contacting processes , 2006 .

[18]  You-In Park,et al.  Comparison of Porous Hollow Fibers As a Membrane Contactor for Carbon Dioxide Absorption , 2002 .

[19]  G. Versteeg,et al.  Membrane–solvent selection for CO2 removal using membrane gas–liquid contactors , 2004 .

[20]  Pierce W.F. Riemer,et al.  Greenhouse gas mitigation technologies, an overview of the CO2 capture, storage and future activities of the IEA Greenhouse Gas R&D programme , 1996 .

[21]  A. Ismail,et al.  Hollow fiber gas-liquid membrane contactors for acid gas capture: a review. , 2009, Journal of hazardous materials.

[22]  A. Ismail,et al.  Production of super selective polysulfone hollow fiber membranes for gas separation , 1999 .

[23]  K. Sirkar,et al.  Dispersion‐free solvent extraction with microporous hollow‐fiber modules , 1988 .

[24]  Roberto M. Narbaitz,et al.  A study of mass transfer in the membrane air-stripping process using microporous polyproplylene hollow fibers , 2000 .

[25]  Norman N. Li Advanced membrane technology and applications , 2008 .

[26]  Aihua Yang,et al.  Effect of internal coagulant on effectiveness of polyvinylidene fluoride membrane for carbon dioxide separation and absorption , 2008 .

[27]  K. Kimmerle,et al.  Analysis of the structure-determining process of phase inversion membranes , 1990 .

[28]  Paitoon Tontiwachwuthikul,et al.  Comparing the Absorption Performance of Packed Columns and Membrane Contactors , 2005 .

[29]  B. Mandal,et al.  Removal of CO2 by Single and Blended Aqueous Alkanolamine Solvents in Hollow-Fiber Membrane Contactor: Modeling and Simulation , 2007 .