Touching force response of the piezoelectric Braille cell

Purpose. The objective of this research is to investigate dynamic responses of the piezoelectric Braille cell when it is subjected to both electrical signal and touching force. Method. Physical behavior of the piezoelectric actuator inside the piezoelectric Braille cell is analyzed. The mathematical model of the piezoelectric Braille system is presented. Then, data of visually impaired people using a Braille Note is studied as design information and a reference input for calculation of the piezoelectric Braille response under the touching force. Results. The results show dynamic responses of the piezoelectric Braille cell. The designed piezoelectric bimorph has a settling time of 0.15 second. The relationship between the Braille dot height and applied voltage is linear. The behavior of the piezoelectric Braille dot when it is touched during operation shows that the dot height is decreased as the force increases. Conclusions. The result provides understanding of the piezoelectric Braille cell behavior under both touching force and electrical excitation simultaneously. This is the important issue for the design and development of piezoelectric Braille cells in senses of controlling Braille dot displacement or force-feedback in the future.

[1]  J. Linvill Development progress on a microelectronic tactile facsimile reading aid for the blind , 1969 .

[2]  P. M. Taylor,et al.  A sixty-four element tactile display using shape memory alloy wires , 1998 .

[3]  T P Way,et al.  Automatic visual to tactile translation--Part I: Human factors, access methods, and image manipulation. , 1997, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[4]  Michael Wiertlewski,et al.  A compact tactile display for the blind with shape memory alloys , 2006, Proceedings 2006 IEEE International Conference on Robotics and Automation, 2006. ICRA 2006..

[5]  Ping-chün Wang Numerical and matrix methods in structural mechanics : with applications to computers. , 1966 .

[6]  Willis J. Tompkins,et al.  A 64-Solenoid, Four-Level Fingertip Search Display for the Blind , 1987, IEEE Transactions on Biomedical Engineering.

[7]  P. M. Taylor,et al.  Advances in an electrorheological fluid based tactile array , 1998 .

[8]  M Shinohara,et al.  Three-dimensional tactile display for the blind. , 1998, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[9]  R. Velazquez,et al.  Design and Optimization of Crossbar Architectures for Shape Memory Alloy Actuator Arrays , 2006, 2006 IEEE International Symposium on MicroNanoMechanical and Human Science.

[10]  Frederick J. Lisy,et al.  A novel bulk micromachined electrostatic microvalve with a curved-compliant structure applicable for a pneumatic tactile display , 2001 .

[11]  J. C. Bliss,et al.  A direct translation reading aid for the blind , 1966 .

[12]  George Lindfield,et al.  Numerical Methods Using MATLAB , 1998 .

[13]  D. Durand,et al.  A novel integrable microvalve for refreshable Braille display system , 2003 .

[14]  A. Choudary,et al.  Partial Differential Equations An Introduction , 2010, 1004.2134.

[15]  K. R. Subramanian,et al.  Braille display terminal for personal computers , 1990 .

[16]  Fumihito Arai,et al.  Micro resonator using electromagnetic actuator for tactile display , 1997, 1997 International Symposium on Micromechanics and Human Science (Cat. No.97TH8311).

[17]  Jae-Bok Song,et al.  Development of a Braille Display using Piezoelectric Linear Motors , 2006, 2006 SICE-ICASE International Joint Conference.

[18]  H. Tzou Piezoelectric Shells: Distributed Sensing and Control of Continua , 1993 .