Detecting Defects in Porcelain Postinsulator Coated With Room Temperature Vulcanized Silicone Rubber by Pulsed Thermography

Nondestructive testing is of great significance for preventing fracture accidents of porcelain postinsulators, especially coated with room temperature vulcanized (RTV) silicone rubber. In this paper, the feasibility of pulsed thermography for defects detection of porcelain postinsulators was investigated. 110-kV porcelain postinsulators with crack defects were tested by utilizing the investigated approach. The results show that crack defect as small as 0.4 mm under the RTV silicone rubber coating with the thickness of 1 mm can be accurately identified. Homomorphic filtering method with Fourier transform was applied to correct the nonuniform heating and improve the defect contrast in the thermal images. With the advantages of simple operation, contactless measurement, full-field imaging, and quantitative defect estimation capability, the pulsed thermography would have promising applications in live detection of porcelain postinsulators.

[1]  Jangmyung Lee,et al.  Inspection of Insulators on High-Voltage Power Transmission Lines , 2009, IEEE Transactions on Power Delivery.

[2]  Kiarash Ahi,et al.  Mathematical Modeling of THz Point Spread Function and Simulation of THz Imaging Systems , 2017, IEEE Transactions on Terahertz Science and Technology.

[3]  Xavier Maldague,et al.  Non-destructive Investigation of Paintings on Canvas by Continuous Wave Terahertz Imaging and Flash Thermography , 2017, Journal of Nondestructive Evaluation.

[4]  Steven M. Shepard,et al.  Advances in thermographic signal reconstruction , 2015, Commercial + Scientific Sensing and Imaging.

[5]  Xavier Maldague,et al.  Theory and Practice of Infrared Technology for Nondestructive Testing , 2001 .

[6]  Yunlong Sheng,et al.  An experimental and analytical study of micro-laser line thermography on micro-sized flaws in stitched carbon fiber reinforced polymer composites , 2016 .

[7]  Pietro Burrascano,et al.  Exploiting Pseudorandom Sequences to Enhance Noise Immunity for Air-Coupled Ultrasonic Nondestructive Testing , 2012, IEEE Transactions on Instrumentation and Measurement.

[8]  Julien Fleuret,et al.  Automated assessment and tracking of human body thermal variations using unsupervised clustering. , 2016, Applied optics.

[9]  Pasquale Daponte,et al.  An improved method for automatic detection and location of defects in electronic components using scanning ultrasonic microscopy , 2003, IEEE Trans. Instrum. Meas..

[10]  T. V. Ferreira,et al.  Intelligent acoustic detection of defective porcelain station post insulators , 2014, 2014 International Conference on Advances in Communication and Computing Technologies (ICACACT 2014).

[11]  Clemente Ibarra-Castanedo,et al.  Optical and Mechanical Excitation Thermography for Impact Response in Basalt-Carbon Hybrid Fiber-Reinforced Composite Laminates , 2018, IEEE Transactions on Industrial Informatics.

[12]  Hai Zhang,et al.  The axial crack testing model for long distance oil-gas pipeline based on magnetic flux leakage internal inspection method , 2017 .

[13]  Fabio Leccese,et al.  Development on aerospace composite structures investigation using thermography and shearography in comparison to traditional NDT methods , 2015, 2015 IEEE Metrology for Aerospace (MetroAeroSpace).

[14]  S. M. Ale-emran,et al.  Experimental Design of Booster-Shed Parameters for Post Insulators under Heavy Icing Conditions , 2015, IEEE Transactions on Power Delivery.

[16]  Wei Zhang,et al.  Method for Removing Secondary Peaks in Remote Field Eddy Current Testing of Pipes , 2017 .

[17]  Pulsed X-ray induced partial discharge diagnostics for routine testing of solid GIS insulators , 2013, IEEE Transactions on Dielectrics and Electrical Insulation.

[18]  Z. Jia,et al.  Development of RTV Silicone Coatings in China: Overview and Bibliography [Feature article] , 2008, IEEE Electrical Insulation Magazine.

[19]  Xavier Maldague,et al.  Thermographic Non-Destructive Evaluation for Natural Fiber-Reinforced Composite Laminates , 2018 .

[20]  Mahmood Hosseini,et al.  Experimental System Identification of a 63kV Substation Post Insulator and the Development of Its Fragility Curves by Dynamic Finite Element Analyses , 2017 .

[21]  Steven M. Shepard,et al.  Advances in pulsed thermography , 2001, SPIE Defense + Commercial Sensing.

[22]  Jianying Li,et al.  Condition monitoring and diagnosis of power equipment: review and prospective , 2017 .

[23]  Yunze He,et al.  Impact evaluation in carbon fiber reinforced plastic (CFRP) laminates using eddy current pulsed thermography , 2014 .

[24]  T. Orbeck,et al.  Protective coatings for improving contamination performance of outdoor high voltage ceramic insulators , 1995 .

[25]  Z. Jia,et al.  Investigation on Field-Aged RTV-Coated Insulators Used in Heavily Contaminated Areas , 2007, IEEE Transactions on Power Delivery.

[26]  Steven M. Shepard Advances in thermographic NDT , 2003, SPIE Defense + Commercial Sensing.