Robust control of an isolated hybrid wind-diesel power system using Linear Quadratic Gaussian approach

This paper presents the application of the Linear Quadratic Gaussian (LQG) controller for voltage and frequency regulation of an isolated hybrid wind–diesel scheme. The scheme essentially consists of a vertical axis wind turbine driving a self-excited induction generator connected via an asynchronous (AC–DC–AC) link to a synchronous generator driven by a diesel engine. The synchronous generator is equipped with a voltage regulator and a static exciter. The wind generator and the synchronous generator together cater for the local load and power requirement. However, the load bus voltage and frequency are governed by the synchronous generator. The control objective aims to regulate the load voltage and frequency. This is accomplished via controlling the field voltage and rotational speed of the synchronous generator. The complete nonlinear dynamic model of the system has been described and linearized around an operating point. The standard Kalman filter technique has been employed to estimate the full states of the system. The computational burden has been minimized to a great extent by computing the optimal state feedback gains and the Kalman state space model off-line. The proposed controller has the advantages of robustness, fast response and good performance. The hybrid wind diesel energy scheme with the proposed controller has been tested through a step change in both wind speed and load impedance. Simulation results show that accurate tracking performance of the proposed hybrid wind diesel energy system has been achieved.

[1]  Ramesh C. Bansal,et al.  Automatic Reactive-Power Control of Isolated Wind-Diesel Hybrid Power Systems , 2006, IEEE Trans. Ind. Electron..

[2]  Ramesh C. Bansal,et al.  Automatic reactive power control of wind-diesel-micro-hydro autonomous hybrid power systems using ANN tuned static VAr compensator , 2003, Large Engineering Systems Conference on Power Engineering, 2003.

[3]  R. Chedid,et al.  Adaptive fuzzy control for wind-diesel weak power systems , 2000, 2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077).

[4]  Francisco Jurado,et al.  Neuro-fuzzy control for autonomous wind–diesel systems using biomass , 2002 .

[5]  J. Clare,et al.  A hybrid topology for a variable speed wind-diesel generation system using wound rotor induction machines , 2005, 31st Annual Conference of IEEE Industrial Electronics Society, 2005. IECON 2005..

[6]  William Leithead,et al.  Classical control of active pitch regulation of constant speed horizontal axis wind turbines , 1992 .

[7]  Syed Islam,et al.  A Neuro-fuzzy Model for the Control Operation of a Wind-diesel-battery Hybrid Power System , 2003 .

[8]  V. Wilreker,et al.  Wind Turbine Generator Interaction With Diesel Generators on an Isolated Power System , 1984, IEEE Transactions on Power Apparatus and Systems.

[9]  R. Chedid,et al.  Adaptive fuzzy control for wind-diesel weak power systems , 2000 .

[10]  A. Ilinca,et al.  Study of a Hybrid Wind-Diesel System with Compressed Air Energy Storage , 2007, 2007 IEEE Canada Electrical Power Conference.

[11]  Wilsun Xu,et al.  Control design and dynamic performance analysis of a wind turbine-induction generator unit , 2000 .

[12]  J. T. Bialasiewicz,et al.  Modular simulation of a hybrid power system with diesel and wind turbine generation , 1998 .