Practical issues in the implementation of electro-mechanical impedance technique for NDE

The electro-mechanical impedance (EMI) technique, which utilizes "smart" piezoceramic (PZT) patches as collocated actuator-sensors, has recently emerged as a powerful technique for diagnosing incipient damages in structures and machines. This technique utilizes the electro-mechanical admittance of a PZT patch surface bonded to the structure as the diagnostic signature of the structure. The operating frequency is typically maintained in the kHz range for optimum sensitivity in damage detection. However, there are many impediments to the practical application of the technique for NDE of real-life structures, such as aerospace systems, machine parts, and civil-infrastructures like buildings and bridges. The main challenge lies in achieving consistent behavior of the bonded PZT patch over sufficiently long periods, typically of the order of years, under "harsh" environment. This necessitates protecting the PZT patch from environmental effects. This paper reports a dedicated investigation stretched over several months to ascertain the long-term consistency of the electro-mechanical admittance signatures of PZT patches. Possible protection of the patch by means of suitable covering layer as well as the effects of the layer on damage sensitivity of the patch are also investigated. It is found that a suitable cover is necessary to protect the PZT patch, especially against humidity and to ensure long life. It is also found that the patch exhibits a high sensitivity to damage even in the presence of the protection layer. The paper also includes a brief discussion on few recent applications of the EMI technique and possible use of multiplexing to optimize sensor interrogation time.

[1]  Balkrishna S. Annigeri,et al.  Structural Health Monitoring With Piezoelectric Active Sensors , 2001 .

[2]  Chee Kiong Soh,et al.  Health Monitoring Of Civil Infrastructure Using Smart PiezoelectricTransducer Patches , 2000 .

[3]  Suresh. Bhalla,et al.  SMART SYSTEM BASED AUTOMATED HEALTH MONITORING OF STRUCTURES , 2001 .

[4]  Victor Giurgiutiu,et al.  Recent advancements in the electromechanical (E/M) impedance method for structural health monitoring and NDE , 1998, Smart Structures.

[5]  C. Liang,et al.  Coupled Electro-Mechanical Analysis of Adaptive Material Systems-Determination of the Actuator Power Consumption and System Energy Transfer , 1997 .

[6]  Daniel J. Inman,et al.  Feasibility of using impedance‐based damage assessment for pipeline structures , 2001 .

[7]  Daniel J. Inman,et al.  Improving Accessibility of the Impedance-Based Structural Health Monitoring Method , 2004 .

[8]  Daniel J. Inman,et al.  Impedance-Based Structural Health Monitoring for Temperature Varying Applications , 1999 .

[9]  Suresh Bhalla,et al.  Performance of smart piezoceramic patches in health monitoring of a RC bridge , 2000 .

[10]  Victor Giurgiutiu,et al.  Active sensors for health monitoring of aging aerospace structures , 2000, Smart Structures.

[11]  M. Saafi,et al.  Health monitoring of concrete structures strengthened with advanced composite materials using piezoelectric transducers , 2001 .

[12]  Suresh Bhalla,et al.  Influence of structure-actuator interactions and temperature on piezoelectric mechatronic signatures for NDE , 2003, Other Conferences.

[13]  Craig A. Rogers,et al.  Qualitative impedance-based health monitoring of civil infrastructures , 1998 .

[14]  Daniel J. Inman,et al.  IMPEDANCE-BASED HEALTH MONITORING OF CIVIL STRUCTURAL COMPONENTS , 2000 .