SI-traceable measurement of an optical frequency at the low 10-16 level without a local primary standard.

SI-traceable measurements of optical frequencies using International Atomic Time (TAI) do not require a local primary frequency reference, but suffer from an uncertainty in tracing to the SI second. For the measurement of the 87Sr lattice clock transition, we have reduced this uncertainty to the low 10-16 level by averaging three sets of ten-day intermittent measurements, in which we operated the lattice clock for 104 s on each day. Moreover, a combined oscillator of two hydrogen masers was employed as a local flywheel oscillator (LFO) in order to mitigate the impact of sporadic excursion of LFO frequency. The resultant absolute frequency with fractional uncertainty of 4.3 × 10-16 agrees with other measurements based on local state-of-the-art cesium fountains.

[1]  G. Panfilo,et al.  A theoretical and experimental analysis of frequency transfer uncertainty, including frequency transfer into TAI , 2010 .

[2]  Tomonari Suzuyama,et al.  Improved Frequency Measurement of the 1 S 0 - 3 P 0 Clock Transition in 87 Sr Using a Cs Fountain Clock as a Transfer Oscillator , 2015, 1509.03967.

[3]  Y. Li,et al.  Stability Transfer between Two Clock Lasers Operating at Different Wavelengths for Absolute Frequency Measurement of Clock Transition in 87Sr , 2012, 1201.3159.

[4]  P. Rosenbusch,et al.  Experimental realization of an optical second with strontium lattice clocks , 2013, Nature Communications.

[5]  L. Tisserand,et al.  A new prediction algorithm for the generation of International Atomic Time , 2012 .

[6]  Tomonari Suzuyama,et al.  Spectroscopy and frequency measurement of the 87Sr clock transition by laser linewidth transfer using an optical frequency comb , 2014, 1401.1008.

[7]  Jun Ye,et al.  Sr Lattice Clock at 1 × 10–16 Fractional Uncertainty by Remote Optical Evaluation with a Ca Clock , 2008, Science.

[8]  Michito Imae,et al.  Development of multichannel dual-mixer time difference system to generate UTC (NICT) , 2005, IEEE Transactions on Instrumentation and Measurement.

[9]  Uwe Sterr,et al.  High accuracy correction of blackbody radiation shift in an optical lattice clock. , 2012, Physical review letters.

[10]  M. Granveaud,et al.  Estimation of the Scale Unit Duration of Time Scales , 1977 .

[11]  P Tavella,et al.  Atomic clock prediction based on stochastic differential equations , 2008 .

[12]  Tianchu Li,et al.  First Evaluation and Frequency Measurement of the Strontium Optical Lattice Clock at NIM , 2015 .

[13]  M. Weiss,et al.  Uncertainty of a frequency comparison with distributed dead time and measurement interval offset , 2007 .

[14]  Yuko Hanado,et al.  Rapid evaluation of time scale using an optical clock , 2016 .

[15]  T L Nicholson,et al.  Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty , 2014, Nature Communications.

[16]  Dai-Hyuk Yu,et al.  Absolute frequency measurement of 1S0 (F = 1/2) - 3P0 (F = 1/2) transition of 171Yb atoms in a one-dimensional optical lattice at KRISS , 2011 .

[17]  Wei Zhang,et al.  An optical lattice clock with accuracy and stability at the 10−18 level , 2013, Nature.

[18]  P. Lemonde,et al.  Observation and cancellation of a perturbing dc stark shift in strontium optical lattice clocks , 2011, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[19]  H. Schnatz,et al.  The 87Sr optical frequency standard at PTB , 2011, 1104.4850.

[20]  E. Burt,et al.  Lattice-induced frequency shifts in Sr optical lattice clocks at the 10(-17) level. , 2011, Physical review letters.

[21]  Tetsuya Ido,et al.  Absolute frequency measurement with uncertainty below $$1\times 10^{-15}$$1×10-15 using International Atomic Time , 2016, 1611.08668.

[22]  Vladislav Gerginov,et al.  A strontium lattice clock with 3 × 10 − 17 ?> inaccuracy and its frequency , 2013, 1312.3419.

[23]  D. W. Allan,et al.  Time and Frequency (Time-Domain) Characterization, Estimation, and Prediction of Precision Clocks and Oscillators , 1987, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[24]  Zichao Zhou,et al.  88Sr+ 445-THz single-ion reference at the 10(-17) level via control and cancellation of systematic uncertainties and its measurement against the SI second. , 2012, Physical review letters.

[25]  T. Ido,et al.  Intermittent optical frequency measurements to reduce the dead time uncertainty of frequency link , 2015, 1508.05996.

[26]  S. Weyers,et al.  Realization of a timescale with an accurate optical lattice clock , 2015, 1511.03888.

[27]  Eva Bookjans,et al.  Optical to microwave clock frequency ratios with a nearly continuous strontium optical lattice clock , 2016, 1605.03878.

[28]  Charles W. Clark,et al.  Blackbody-radiation shift in the Sr optical atomic clock , 2012, 1210.7272.

[29]  Fritz Riehle,et al.  Towards a Re-definition of the Second Based on Optical Atomic Clocks , 2015, 1501.02068.

[30]  Kurt Gibble Scattering of cold-atom coherences by hot atoms: frequency shifts from background-gas collisions. , 2013, Physical review letters.

[31]  K. Gao,et al.  Frequency Comparison of Two (40)Ca(+) Optical Clocks with an Uncertainty at the 10(-17) Level. , 2016, Physical review letters.