Association between classroom ventilation mode and learning outcome in Danish schools

Abstract Associations between learning, ventilation mode, and other classroom characteristics were investigated with data from a Danish test scheme and two widespread cross-sectional studies examining air quality in Danish schools. An academic achievement indicator as a measure of the learning outcome was calculated from the scores of a standardized Danish test scheme adjusted for a socioeconomic reference index. Pupils in schools with balanced mechanical ventilation had significantly higher achievement indicators than pupils in schools with natural ventilation, where airing took place mostly by manual window opening. Also, the carbon dioxide concentration was lower in classrooms with balanced mechanical ventilation. There was no consistent association between the achievement indicators and the person specific room volume, construction/renovation year, or the occupancy. Measurements of carbon dioxide concentrations and temperatures in 820 classrooms in 389 schools were available. In 56% and 66% of the classrooms included in the two studies, the measured CO2 concentration was higher than 1000 ppm. The findings of this study add to the growing evidence that insufficient classroom ventilation have impacts on learning outcomes.

[1]  Olga Perfilieva,et al.  Qualifications Systems: Bridges to Lifelong Learning , 2007 .

[2]  N. Kochhar,et al.  Ventilation Rates in Schools and Learning Performance , 2007 .

[3]  A. Myhrvold,et al.  Pupils health and performance due to renovation of schools , 1997 .

[4]  M G Apte,et al.  Indoor air quality, ventilation and health symptoms in schools: an analysis of existing information. , 2003, Indoor air.

[5]  M G Apte,et al.  Association of classroom ventilation with reduced illness absence: a prospective study in California elementary schools , 2013, Indoor air.

[6]  Tiina Pohjonen,et al.  School environment as predictor of teacher sick leave: data-linked prospective cohort study , 2012, BMC Public Health.

[7]  Pawel Wargocki,et al.  Providing better thermal and air quality conditions in school classrooms would be cost-effective , 2013 .

[8]  D. Hosmer,et al.  Applied Logistic Regression , 1991 .

[9]  D Faulkner,et al.  Associations between classroom CO2 concentrations and student attendance in Washington and Idaho. , 2004, Indoor air.

[10]  Douglas D. Ready Socioeconomic Disadvantage, School Attendance, and Early Cognitive Development , 2010 .

[11]  Steve Turner,et al.  Classroom carbon dioxide concentration, school attendance, and educational attainment. , 2014, The Journal of school health.

[12]  Derek Clements-Croome,et al.  Ventilation rates in schools and pupils' performance , 2012 .

[13]  S. Siegel,et al.  Nonparametric Statistics for the Behavioral Sciences , 2022, The SAGE Encyclopedia of Research Design.

[14]  Peter Foldbjerg,et al.  Socio-Economic Consequences of Improved Indoor Air Quality in Danish Primary Schools , 2014 .

[15]  Yi Wang,et al.  Ventilation system type, classroom environmental quality and pupils' perceptions and symptoms , 2014 .

[16]  Pawel Wargocki,et al.  The Effects of Outdoor Air Supply Rate and Supply Air Filter Condition in Classrooms on the Performance of Schoolwork by Children (RP-1257) , 2007 .

[17]  I. Annesi-Maesano,et al.  School air quality related to dry cough, rhinitis and nasal patency in children , 2010, European Respiratory Journal.

[18]  Richard Woodward,et al.  The Organisation for Economic Co-operation and Development (OECD) , 2009 .

[19]  P. Wargocki,et al.  The Effects of Moderately Raised Classroom Temperatures and Classroom Ventilation Rate on the Performance of Schoolwork by Children (RP-1257) , 2007 .

[20]  G. Heath,et al.  Do indoor pollutants and thermal conditions in schools influence student performance? A critical review of the literature. , 2005, Indoor air.

[21]  C. Kielb,et al.  The impact of school building conditions on student absenteeism in Upstate New York. , 2010, American journal of public health.

[22]  U. Haverinen-Shaughnessy,et al.  Association between substandard classroom ventilation rates and students' academic achievement. , 2011, Indoor air.