Fracture mechanics of the femoral neck in a composite bone model: effects of platen geometry.

Load applicator (platen) geometry used for axial load to failure testing of the femoral neck varies between studies and the biomechanical consequences are unknown. The purpose of this study was to determine if load application with a flat versus a conical platen results in differing fracture mechanics. Femurs were aligned in 25° of adduction and an axial compressive force was applied to the femoral heads at a rate of 6 mm/min until failure. Load application with the conical platen resulted in an average ultimate failure load, stiffness, and energy to failure of 9067 N, 4033 N/mm, and 12.12 J, respectively. Load application with the flat platen resulted in a significant (p<0.05) reduction in ultimate failure load (7620 N) and stiffness (2924 N/mm). Energy to failure (12.30 J) was not significantly different (p=0.893). Different fracture patterns were observed for the two platens and the conical platen produced fractures more similar to clinical observations. Use of a flat platen underestimates the strength and stiffness of the femoral neck and inaccurately predicts the associated fracture pattern. These findings must be considered when interpreting the results of prior biomechanical studies on femoral neck fracture and for the development of future femoral neck fracture models.

[1]  R. S. Garden,et al.  Subcapital fractures of the femur. A prospective review. , 1976, The Journal of bone and joint surgery. British volume.

[2]  P. Wooley,et al.  Mechanical Evaluation of Large-Size Fourth-Generation Composite Femur and Tibia Models , 2010, Annals of Biomedical Engineering.

[3]  T. Heinz,et al.  Predictive geometric factors in a standardized model of femoral neck fracture. Experimental study of cadaveric human femurs. , 2002, Injury.

[4]  R. Zdero,et al.  A biomechanical and finite element analysis of femoral neck notching during hip resurfacing. , 2009, Journal of biomechanical engineering.

[5]  R Zdero,et al.  The biomechanics of human femurs in axial and torsional loading: comparison of finite element analysis, human cadaveric femurs, and synthetic femurs. , 2007, Journal of biomechanical engineering.

[6]  J. Bartoníček,et al.  [Mortality in patients with proximal femoral fractures during the first year after the injury]. , 2002, Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca.

[7]  Kenton R Kaufman,et al.  Surgical treatment of femoroacetabular impingement: evaluation of the effect of the size of the resection. , 2005, The Journal of bone and joint surgery. American volume.

[8]  A. Heiner Structural properties of fourth-generation composite femurs and tibias. , 2008, Journal of biomechanics.

[9]  M. Bosse CAQ: Orthopaedic Trauma "Damage Control". , 2007, Journal of orthopaedic trauma.

[10]  R. LaPrade,et al.  Cam lesion femoral osteoplasty: in vitro biomechanical evaluation of iatrogenic femoral cortical notching and risk of neck fracture. , 2013, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[11]  W. Ekström,et al.  Risk factors for osteoporosis are common in young and middle-aged patients with femoral neck fractures regardless of trauma mechanism , 2013, Acta orthopaedica.

[12]  R. Zdero,et al.  Cyclic loading of periprosthetic fracture fixation constructs. , 2008, The Journal of trauma.

[13]  J. Kurtinaitis,et al.  Mortality after femoral neck fractures: a two-year follow-up. , 2012, Medicina.

[14]  G. Holzer,et al.  Hip Fractures and the Contribution of Cortical Versus Trabecular Bone to Femoral Neck Strength , 2009, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[15]  J. Klaksvik,et al.  Biomechanical femoral neck fracture experiments--a narrative review. , 2012, Injury.

[16]  M. Péntek,et al.  [Correlation between risk factors and mortality in elderly patients with femoral neck fracture with 5-year follow-up]. , 2008, Orvosi hetilap.

[17]  Intracapsular fractures of the neck of the femur. , 1970, The Journal of bone and joint surgery. British volume.

[18]  C. Court-Brown,et al.  Hip Fractures in Adults Younger Than 50 Years of Age Epidemiology and Results , 1995, Clinical orthopaedics and related research.

[19]  R. Zdero,et al.  Femoral Head Lag Screw Position for Cephalomedullary Nails: A Biomechanical Analysis , 2012, Journal of orthopaedic trauma.

[20]  G. Bergmann,et al.  Hip contact forces and gait patterns from routine activities. , 2001, Journal of biomechanics.

[21]  Femoral neck fractures after arthroscopic femoral neck osteochondroplasty for femoroacetabular impingement , 2014, Knee Surgery, Sports Traumatology, Arthroscopy.

[22]  R. Zdero,et al.  The effect of load application rate on the biomechanics of synthetic femurs , 2010, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[23]  Emil H. Schemitsch,et al.  Fixation of long bone segmental defects: a biomechanical study. , 2008, Injury.

[24]  F. Kummer,et al.  Basicervical Fractures of the Proximal Femur: A Biomechanical Study of 3 Internal Fixation Techniques , 1994, Clinical orthopaedics and related research.

[25]  R. Zdero,et al.  The biomechanical effect of changes in cancellous bone density on synthetic femur behaviour , 2011, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[26]  L. Audigé,et al.  Fracture and dislocation classification compendium - 2007: Orthopaedic Trauma Association classification, database and outcomes committee. , 2007, Journal of orthopaedic trauma.

[27]  R. Zdero,et al.  Biomechanical evaluation of periprosthetic femoral fracture fixation. , 2008, The Journal of bone and joint surgery. American volume.