Efficient Homogeneously Weighted Moving Average Chart for Monitoring Process Mean Using an Auxiliary Variable

In this paper, we propose an efficient control chart for monitoring small shifts in a process mean for scenarios where the process variable is observed with a correlated auxiliary variable. The proposed chart, called an auxiliary homogeneously weighted moving average (AHWMA) chart, is a homogeneously weighted moving average type control chart that uses both the process and auxiliary variables in the form of a regression estimator to provide an efficient and unbiased estimate of the mean of the process variable. We provide the design structure of the chart and examine its performance in terms of its run length properties. Using a simulation study, we compare its run length performance with several existing methods for detecting a small shift in the process mean. Our simulation results show that the proposed chart is more efficient in detecting a small shift in the process mean than its competitors. We provide a detailed study of the chart’s robustness to non-normal distributions and show that the chart may also be designed to be less sensitive to non-normality. We give some recommendations on the application of the chart when the process parameters are unknown and provide an example to show the implementation of the proposed new technique.

[1]  Sven Knoth Supplementary material: ARL Numerics for MEWMA Charts , 2017 .

[2]  Gerd Ronning A Simple Scheme for Generating Multivariate Gamma Distributions with Non-Negative Covariance Matrix , 1977 .

[3]  Connie M. Borror,et al.  Robustness properties of multivariate EWMA control charts , 2003 .

[4]  Muhammad Riaz,et al.  An EWMA-Type Control Chart for Monitoring the Process Mean Using Auxiliary Information , 2014 .

[5]  K. Srikaeo,et al.  The use of statistical process control (SPC) to enhance the validation of critical control points (CCPs) in shell egg washing , 2002 .

[6]  Saddam Akber Abbasi,et al.  Multivariate coefficient of variation control charts in phase I of SPC , 2018, The International Journal of Advanced Manufacturing Technology.

[7]  Yan Hong,et al.  Implementation of Statistical Process Control (SPC) in the Sewing Section of Garment Industry for Quality Improvement , 2018, Autex Research Journal.

[8]  M. A. Sharaf El-Din,et al.  Statistical Process Control Charts Applied to Steelmaking Quality Improvement , 2006 .

[9]  Muhammad Riaz,et al.  Monitoring process mean level using auxiliary information , 2008 .

[10]  Connie M. Borror,et al.  Robustness of the EWMA Control Chart to Non-Normality , 1999 .

[11]  Abdul Haq,et al.  A new adaptive EWMA control chart using auxiliary information for monitoring the process mean , 2018 .

[12]  Jyh-Jen Horng Shiau,et al.  A MULTIVARIATE CONTROL CHART FOR DETECTING INCREASES IN PROCESS DISPERSION , 2010 .

[13]  Muhammad Riaz,et al.  EWMA-type scheme for monitoring location parameter using auxiliary information , 2017, Comput. Ind. Eng..

[14]  Saddam Akber Abbasi,et al.  Bayesian Monitoring of Linear Profiles Using DEWMA Control Structures With Random $X$ , 2018, IEEE Access.

[15]  Chi-Hyuck Jun,et al.  A Multivariate Control Chart for Monitoring Several Exponential Quality Characteristics Using EWMA , 2018, IEEE Access.

[16]  R Core Team,et al.  R: A language and environment for statistical computing. , 2014 .

[17]  Charles W. Champ,et al.  The Performance of Exponentially Weighted Moving Average Charts With Estimated Parameters , 2001, Technometrics.

[18]  Subhabrata Chakraborti,et al.  Robustness of the EWMA control chart for individual observations , 2011 .

[19]  Saddam Akber Abbasi,et al.  A Multivariate Homogeneously Weighted Moving Average Control Chart , 2019, IEEE Access.

[20]  Muhammad Riaz,et al.  Monitoring process variability using auxiliary information , 2008, Comput. Stat..

[21]  William G. Cochran,et al.  Sampling Techniques, 3rd Edition , 1963 .

[22]  Muhammad Riaz,et al.  Mixed Exponentially Weighted Moving Average–Cumulative Sum Charts for Process Monitoring , 2013, Qual. Reliab. Eng. Int..

[23]  Marion R. Reynolds,et al.  Robustness to non-normality and autocorrelation of individuals control charts , 2000 .

[24]  S. W. Roberts Control chart tests based on geometric moving averages , 2000 .

[25]  Muhammad Riaz,et al.  On Designing Mixed EWMA Dual-CUSUM Chart With Applications in Petro-Chemical Industry , 2018, IEEE Access.

[26]  Nasir Abbas,et al.  Homogeneously weighted moving average control chart with an application in substrate manufacturing process , 2018, Comput. Ind. Eng..

[27]  Anders Ringgaard Kristensen,et al.  A model for monitoring the condition of young pigs by their drinking behaviour , 2005 .

[28]  Abdul Haq,et al.  New Synthetic CUSUM and Synthetic EWMA Control Charts for Monitoring the Process Mean using Auxiliary Information , 2017, Qual. Reliab. Eng. Int..

[29]  Saddam Akber Abbasi,et al.  Shrinkage estimates of covariance matrices to improve the performance of multivariate cumulative sum control charts , 2018, Comput. Ind. Eng..

[30]  B. J. Mandel The Regression Control Chart , 1969 .

[31]  E. S. Page Cumulative Sum Charts , 1961 .

[32]  Charles W. Champ,et al.  Effects of Parameter Estimation on Control Chart Properties: A Literature Review , 2006 .

[33]  G. D. Hayes,et al.  Applying statistical process control to monitor and evaluate the hazard analysis critical control point hygiene data , 1997 .

[34]  Douglas C. Montgomery,et al.  Statistical quality control : a modern introduction , 2009 .

[35]  Zachary G. Stoumbos,et al.  Robustness to Non-Normality of the Multivariate EWMA Control Chart , 2002 .

[36]  A de Vries,et al.  Design and performance of statistical process control charts applied to estrous detection efficiency. , 2003, Journal of dairy science.

[37]  Sven Knoth Statistical Process Control , 2002 .

[38]  Muhammad Aslam,et al.  Design of a Control Chart for Gamma Distributed Variables Under the Indeterminate Environment , 2019, IEEE Access.

[39]  J C Benneyan,et al.  Statistical Quality Control Methods in Infection Control and Hospital Epidemiology, Part II: Chart Use, Statistical Properties, and Research Issues , 1998, Infection Control & Hospital Epidemiology.

[40]  Saddam Akber Abbasi,et al.  Enhancing the performance of the EWMA control chart for monitoring the process mean using auxiliary information , 2018, Qual. Reliab. Eng. Int..

[41]  Mahmoud A. Mahmoud,et al.  The Performance of the MEWMA Control Chart when Parameters are Estimated , 2010, Commun. Stat. Simul. Comput..

[42]  Stelios Psarakis,et al.  An Examination of the Robustness to Non Normality of the EWMA Control Charts for the Dispersion , 2005 .

[43]  Muhammad Riaz,et al.  On efficient CUSUM-type location control charts using auxiliary information , 2018 .